Abstract
In this study, the electric and magnetic fields measuring system were designed and fabricated to investigate the electric characteristics of lightning discharges. Frequency bandwidth of electric field measuring system ranges from 40[Hz] to 2.6[MHz] and its response characteristic is 2.1[(V/m)/mV]. Frequency bandwidth of magnetic field measuring system ranges from 300[Hz] to 1[MHz] and its response characteristic is 2.8[nT/mV]. Electric and magnetic fields due to intracloud lightning discharges were observed and their waveform parameters were statistically analyzed. As a result, waveform parameters of electric and magnetic fields are nearly independent of polarity. The mean rise times and the zero-crossing times of electric and magnetic fields are approximately $5.5[{\mu}s]\;and\;21[{\mu}s]$, respectively.
본 연구에서는 뇌방전의 전기적 특성에 대해 파악하고자 전계 및 자계 측정시스템을 구축하였다. 주파수 대역 및 응답감도는 전계측정시스템 $40[Hz]{\sim}2.6[MHz]$, 2.1[(V/m)/mV], 자계 측정시스템 $300[Hz]{\sim}1[MHz]$, 28[nT/mV]이다. 구축한 측정시스템을 이용하여 뇌방전에 의해 발생한 전계와 자계 파형을 관측하고, 파형의 여러 가지 파라미터에 대해 통계적으로 분석하였다. 그 결과 전계와 자계 파형은 극성의존성이 미약하였으며, 전계와 자계 파형의 상승시간과 영점교차시간의 평균값은 각각 $5.5[{\mu}s],\;21[{\mu}s]$로 나타났다.