Abstract
This paper proposes a regeneration inverter system, which can regenerate the excessive power form do bus line to ac source for traction system. The proposed regeneration inverter system for dc traction can reduce harmonics which are included to ac current source. The regeneration inverter is operated as two modes. In the regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and in the active power filter mode, it can compensate harmonic distortion produced by the rectifier substation. In this paper, the regeneration inverter uses PWM DC/AC inverter algorithm and the active power filter uses p-q theory. From the informative simulation and experimental results, which are performed wiith a prototype rated 3.7[kw], it can expected that the proposed system can be effectively applied in the real traction system rated 100[kw].
본 논문에서는 전철시스템의 직류모선에 발생하는 잉여분의 전력을 교류전원 측으로 회생시킬 수 있는 회생인버터시스템을 제안한다. 제안된 직류 전철용 회생인버터 시스템은 교류 전원 측 전류에 포함되어진 고조파를 제거할 수 있는 기능을 추가하였다. 회생인버터 모드에서는 전철의 감속에 의해 회생되는 에너지를 재사용할 수 있으며, 능동전력필터 모드에서는 정류기에 의해 발생되는 고조파 왜곡을 보상할 수 있다. 논문에서 회생용 인버터는 PWM DC/AC 인버터 알고리즘을 사용하였으며, 능동전력필터는 p-q 이론을 사용하였다. 시뮬레이션은 축소모델[3.7kW]과 동일하게 구성되었다. 시뮬레이션과 실험 결과로부터 두 가지 알고리즘이 실 모델[100kW]에서도 적용되어질 수 있음을 증명하였다.