DOI QR코드

DOI QR Code

Effects of Outer Tube Length on Pool Boiling in an Annulus with Closed Bottoms

하부폐쇄 환상공간의 외부 튜브길이가 풀비등에 미치는 영향

  • Published : 2006.08.01

Abstract

To improve pool boiling heat transfer in an vertical annulus with closed bottoms, the length of an outer tube has been changed from 0.2m to 0.6m. For the test, a heated tube of 19.1mm diameter and water at atmospheric pressure have been used. Annular conditions are made using glass tubes fabricated around the heated tube. The gap size of the annulus is 3.65mm. To elucidate effects of the outer tube length on heat transfer results of the annulus are compared with the data of a single unrestricted tube and the annulus with wider gap size of 6.35mm. Throughout the tests much higher heat transfer coefficients are observed for the annulus of 3.65mm gap size comparing to the other two cases. The change in the outer tube length results in much variation in heat transfer coefficients. Moreover, with shortening the length of outer tube the possibility of the CHF occurrence can be removed.

Keywords

References

  1. Shoji, M., 2004, 'Studies of Boiling Chaos: a Review,' Int. J. Heat Mass Transfer, Vol. 47, pp. 1105 - 1128 https://doi.org/10.1016/j.ijheatmasstransfer.2003.09.024
  2. Corletti, M.M. and Hochreiter, L.E., 1991, 'Advanced Light Water Reactor Passive Residual Heat Removal Heat Exchanger Test,' Proc. of the 1st JSME/ASME Joint International Conference on Nuclear Engineering, Tokyo, Japan, pp. 381-387
  3. Chung, Y.J., Yang, S.H., Kim, H.C. and Zee, S.Q., 2004, 'Thermal Hydraulic Calculation in a Passive Residual Heat Removal System of the SMART-P Plant for Forced and Natural Convection Conditions,' Nuclear Engineering and Design, Vol. 232, pp. 277 - 288 https://doi.org/10.1016/j.nucengdes.2004.07.002
  4. Yao, S.C. and Chang, Y., 1983, 'Pool Boiling Heat Transfer in a Confined Space,' Int. J. Heat Mass Transfer, Vol. 26, pp. 841 - 848 https://doi.org/10.1016/S0017-9310(83)80108-2
  5. Hung, Y.H. and Yao, S.C., 1985, 'Pool Boiling Heat Transfer in Narrow Horizontal Annular Crevices, ASME J. Heat Transfer, Vol. 107, pp. 656 -662 https://doi.org/10.1115/1.3247474
  6. Kang, M.G., 2002, 'Pool Boiling Heat Transfer in Vertical Annular Crevices,' Int. J. Heat Mass Transfer, Vol. 45, No. 15, pp. 3245 - 3249 https://doi.org/10.1016/S0017-9310(02)00040-6
  7. Kang, M.G., 2001, 'Nucleate Pool Boiling Heat Transfer in Vertical Annuli,' Trans. of the KSME B, Vol. 25, No.8, pp. 1113 -1121
  8. Kang, M.G. and Han, Y.H., 2002, 'Effects of Annular Crevices on Pool Boiling Heat Transfer,' Nuclear Engineering and Design, Vol. 213, No. 2-3, pp. 259 - 271 https://doi.org/10.1016/S0029-5493(01)00515-5
  9. Kang, M.G., 2005, 'Effects of Outer Tube Length on Saturated Pool Boiling Heat Transfer in a Vertical Annulus with Closed Bottom,' Int. J. Heat Mass Transfer, Vol. 48, No. 13, pp. 2795-2800 https://doi.org/10.1016/j.ijheatmasstransfer.2005.01.015
  10. Fujita, Y., Ohta, H., Uchida, S. and Nishikawa, K., 1988,. ''Nucleate Boiling Heat Transfer and Critical Heat Flux in Narrow Space Between Rectabgular Spaces,' Int. J. Heat Mass Transfer, Vol. 31, No. 2, pp. 229 - 239 https://doi.org/10.1016/0017-9310(88)90004-X
  11. Passos, J.C., Hirata, F.R., Possamai, L.F.B., Balsamo, M. and Misale, M., 2004, 'Confined Boiling of Fcn and FC87 on a Downward Facing Heating Copper Disk,' Int. J. Heat Fluid Flow, Vol. 25, pp. 313 -319 https://doi.org/10.1016/j.ijheatfluidflow.2003.11.016
  12. Bonjour, J. and Lallemand, M., 1998, 'Flow Patterns During Boiling in a Narrow Space Between Two Vertical Surfaces,' Int. J. Multiphase Flow, Vol. 24, pp. 947-960 https://doi.org/10.1016/S0301-9322(98)00017-2
  13. Kang, M.G., 2001, 'Hysteresis Effects in Pool Boiling of Water,' Trans. of the KSME B, Vol. 25, No. 8, pp. 1037 - 1045