수질제어 및 부식억제제에 의한 상수도관의 내부부식 제어

Internal Corrosion Control of Drinking Water Pipes by pH and Alkalinity Control and Corrosion Inhibitor

  • 구성은 ((재)한국계면공학연구소) ;
  • 우달식 ((재)한국계면공학연구소) ;
  • 이두진 (한국수자원공사, 수자원연구원) ;
  • 김주환 (한국수자원공사, 수자원연구원) ;
  • 안효원 (한국수자원공사, 수자원연구원) ;
  • 문광순 ((재)한국계면공학연구소)
  • 투고 : 2005.12.02
  • 심사 : 2006.04.11
  • 발행 : 2006.04.15

초록

The internal corrosion of water distribution systems is the main cause for the problem of the public health threat as well as water leakage in the damaged pipeline, red water, and odor and taste of the tap water. This study was examined the effect of chemicals used for pH and alkalinity control and corrosion inhibitors for producing the optimal corrosion control method. Corrosion study at different pH and alkalinity indicated that these control using alkaline chemicals was effective in corrosion rate, Fe release reduction, but examined to be increased in turbidity and corrosion-by-products(TTHMs) problems. The turbidity was slightly increased, requiring caution in controlling corrosion with $Ca(OH)_2$. At pH 9.0, TTHMs concentration is increased two times corn pared with non-control of pH. Using the pipe which had experienced 28 years of exposure, iron release was decreased with the corrosion inhibitor. Consequently, pH, Alkalinity control method using alkaline chemicals must be complemented by corrosion inhibitor application for efficient corrosion control.

키워드

참고문헌

  1. 경희대학교 환경연구소 (1996) 수도관의 부식과 방식 대책. 경희대학교 환경연구소
  2. 김도환, 이재인, 한동엽, 이지형, 김동윤, 노재순, 권기원 (2003) 수도관 부식방지를 위한 CCPP 조절유무에 따른 모의관로와 매설관로에서의 중금속농도 변화, 대한환경공학회 2003 추계학술연구발표회 논문집, pp. 1383-1387
  3. 김준환 등 (1998) 먹는물 수질관리기법 개발에 관한 연구(II), 국립환경연구원보
  4. 남상호 (2002) 국내 수돗물의 수질특성 및 방청제 관리 현황, 수도용 방청제 국제워크샵, pp.13-37
  5. 안효원, 우달식 (2004) 상수도 배급수시설 부식방지를 위한 부식억제제 적용의 현안과 과제, 한국상하수도협회지, 8, pp.96-103
  6. 이성식, 성낙창, 이종팔, 박현석, 정미은, 이상준, 윤태경 (2004) 정수처리공정에서 소독부산물인 트리할로메탄의 생성모델, 한국환경과학회지, 13(3), pp.297-300
  7. 환경공학연구정보센터 (2004) 약품투입시설의 설계 및 운영에 관한 사례연구(1), DICER Techlnfo Part II, 3(8), pp.404-415
  8. 환경부 (2004) 고시 제2004-95호, 수처리제의 기준과 규격 및 표시기준
  9. 환경부 (2004) 환경부 보도자료 '7윌부터 정수장의 수질관리방법 강화
  10. 환경부 (2002) 먹는물수질공정시험방법
  11. Abdullah, M.P., Yew, C.E., and Ramli, M.S. (2003) Formation, Modeling and Validation of Trihalomethanes (THM) in Malaysian Drinking Water: a Case Study in the Districts of Tampin, Negeri Sembilan and Sabak Bernam, Selangor, Malaysia, Water Research, 37, pp.4637-4644 https://doi.org/10.1016/j.watres.2003.07.005
  12. AWWA Research Foundation and DVGW-Technologiezentrum Wasser (1996) Internal Corrosion of Water Distribution Systems. AWWA Research Foundation and DVGW-Technologiezentrum Wasser, Denver
  13. Benjamin, M.M., Reiber, S.H., Ferguson, J.F., Vanderwerff, E.A., and Miller, M.W. (1990) Chemistry of Corrosion Inhibitors in Potable Water, AWWA Research Foundation and America Water Works Association
  14. Edwards, M. (2002) US Perspective on Corrosion Inhibitor Use in Potable Water Supplies, International Workshop on Corrosion Inhibitor for Public Water Supply, pp.41-64
  15. Edwards, M., Hidmi, L., and Gladwell, D. (2002) Phosphate Inhibition of Soluble Copper Corrosion By-product Release, Corrosion Science, 44, pp.1057-1071 https://doi.org/10.1016/S0010-938X(01)00112-3
  16. El-Dib, M.A. and Ali, R.K. (1995) THMs Formation during Chlorination of Raw Nile River Water, Water Research, 29(1), pp.375-378 https://doi.org/10.1016/0043-1354(94)00157-3
  17. Gonzalez, Y., Lafont, M.C., and Pebere, N.A. (1996) Synergistic Effect between Zinc Salt and Phosphonic Acid for Corrosion Inhibition of a Carbon Steel, Journal of Applied Electrochemistry, 26, pp.1259-1265
  18. Lin, T.F. and Hoang, S.W. (2000) Inhalation Exposure to THMs from Drinking Water in South Taiwan, The Science of the Total Environment, 246, pp.41-49 https://doi.org/10.1016/S0048-9697(99)00420-9
  19. McNeill, L.S. and Edwards, M. (2000) Phosphate Inhibitors and Red Water in Stagnant Iron Pipes, J. Environ. Engin., 126(12), pp.1096-1102 https://doi.org/10.1061/(ASCE)0733-9372(2000)126:12(1096)
  20. McNeill, L.S. and Edwards, M. (2001) Iron Pipe Corrosion in Distribution Systems, J. AWWA, 93(7), pp.88-100
  21. Nancollas, G.H. (1983) Phosphate Precipitation in Corrosion Protection Reaction Mechanisms, Corrosion, 39(3), pp.77-80 https://doi.org/10.5006/1.3580822
  22. Rozenfeld, I.L. (1981) Corrosion Inhibitors. McGraw-Hill Inc.
  23. Sarin, P., Snoeyink, V.L., Lytle, D.A., and Kriven, W.M. (2004) Iron Corrosion Scales: Model for Scale Growth, Iron Release, and Colored Water Formation, J. Environ. Engin., 130(4), pp.364-373 https://doi.org/10.1061/(ASCE)0733-9372(2004)130:4(364)
  24. Sarin, P., Snoeyink, V.L., Clement, J.A., and Kriven, W.M. (2002) Iron Release from Corroded Unlined Cast Iron Pipe: Effect of pH, Alkalinity, and Orthophosphates in a Soft New England Water, J. AWWA, 96(11), pp.85-96
  25. Volk, C., Dundore, E., Schiermann, J., and Lechevallier, M. (2000) Practical Evaluation of Iron Corrosion Control in a Drinking Water Distribution System, Water Research, 34(6), pp.1967-1974 https://doi.org/10.1016/S0043-1354(99)00342-5