Prediction of Sludge-Water Interface Height Change in Batch Column

Batch Column에서의 슬러지계면층 높이변화 예측

  • 박석균 (광운대학교 환경공학과) ;
  • 강선홍 (광운대학교 환경공학과)
  • Received : 2006.01.11
  • Accepted : 2006.02.08
  • Published : 2006.02.15

Abstract

While sludge is settling in batch column, sludge concentration becomes high. Because the characteristic of sludge settling changes in function of time due to the sludge concentration change, the sludge settling velocity changes too. Also, because the sludge settling characteristic is influenced by a physical characteristic of sludge and a column height etc, it is difficult to exactly measure the sludge settling characteristic. Although the sludge volume indexes, SVI, SSVI and $SSVI_{3.5}$, are used to predict sludge settling characteristic, these indexes are not reliable values. Because the previously established models for sludge settling velocity predict the sludge settling velocity only, it is difficult to predict sluge-water interface height by using those models. The purpose of this experiment is to establish the empirical model which predicts the sludge interface height change with respect to the sludge physical characteristic and the settling condition.

Keywords

References

  1. Akca L, Kinaci C, Karpuzcu M. (1993) A model for optimum design of activated sludge plants. Water Res, 27(9), pp 1461-1468 https://doi.org/10.1016/0043-1354(93)90026-E
  2. Christopher, M.B. and Peter L.D. (1998) Sludge Volume index Settleability measure: effect of solids characteristic and test parameter, Wat. Env. Res. 70, pp. 87-93 https://doi.org/10.2175/106143098X126928
  3. Daigger. G.T. and Roper, R.E., Jr. (1985) The relationship between SVI and activated sludge settling characteristics. Journal Water Pollution Control Federation, 57(8), pp. 859-866
  4. Daigger, G.T. (1995) Development of refind clarifier operating diagrams using an updated settling characteristics database. Water Environment Research, 67(21), pp. 95-100 https://doi.org/10.2175/106143095X131231
  5. Dick, R.I. and Vesilind, P.A. (1969) The sludge volume index - what is it? J. WPCF, 1, pp. 1285-1291
  6. Hartel L., Popel HJ. (1992) A dynamic secondary clarifier model including processes of sludge thickening. Water Sci Technol 1992, 25(6), pp. 267-284 https://doi.org/10.2166/wst.1992.0128
  7. Mines Jr. R.O., Vilagos J.L., Echelberger Jr. W.F., Murphy R.J. (2001) Conventional and AWT mixed-liquor settlingcharacteristics. J Environ EngASCE, 127(3), pp. 249-258 https://doi.org/10.1061/(ASCE)0733-9372(2001)127:3(249)
  8. Ozinsky A.E., Ekama G.A. (1995) Secondary settlingtank modellingand design Part 1: review of theoretical and practical developments. Water SA, (4), pp. 325-332
  9. Renko, E.K. (1996), A model for batch settling curve, Wat. SA, 22(4), pp. 339-344
  10. Renko, E.K. and Sirvio, H. (1997) Optimal Sampling Design for a sludge blanket interface settling model. Wat. Res., 31(5), pp. 1148-1154 https://doi.org/10.1016/S0043-1354(96)00359-4
  11. Koopman, B., and Cadee, K. (1983) rediction of Thickening Capacity Using Diluted Sludge Volume Index. Water Res. (G.B.), 17, p. 1427 https://doi.org/10.1016/0043-1354(83)90274-9
  12. Pitman, A.R. (1984) Settling of nutrient removal activated sludges. Water Science and Technology, 17, pp. 493-504
  13. Vesilind, P.A. (1968). Design of prototype thickeners from batch settling tests. Water Sew. Works, 115, pp. 302-307
  14. Wahlberg, E.J. and Keinath, T.M. (1988) Development of settling flux curves using SVI. Journal Water Pollution Control Federation, 60(12), pp. 2095-2100
  15. White, M.J.D. (1976) Design and Control of Secondary Settlement Tank, Water Pollut. Control., 75, p. 459