DOI QR코드

DOI QR Code

Corrosion Resistance of Cr-Bearing Rebar to Macrocell Corrosion Environment Induced by Localized Carbonation

  • Tae, Sung-Ho (Dept. of Architectural Engineering, Sustainable Building Research Center, Hanyang University)
  • Published : 2006.06.30

Abstract

Artificial cracks were made in the cover concrete of specimens embedding ten types of steel rebars of different Cr contents. The research aims for developing Cr-bearing steel rebars resistant to macrocell corrosion environments induced by cracking in cover concrete. The cracks were subjected to intensive penetration of carbon dioxide (carbonation specimens) to form macrocells. The carbonation specimens were then treated with accelerated corrosion curing, during which current macrocell corrosion density was measured. The corrosion area and loss from corrosion were also measured at the end of 105 cycles of this accelerated curing. The results of the study showed that Cr-bearing steel with Cr content of 5% or more suppressed corrosion in a macrocell corrosion environment induced by the differences in the pH values due to carbonation of cracked parts. Cr-bearing steels with Cr content of 7% or more are proven to possess excellent corrosion resistance.

Keywords

References

  1. Gowripalan, N., Sirivivatnanon, v., and Lim, C. c., 'Chloride diffusivity of concrete cracked in flexure,' Cement and Concrete Research, Vol.30, 2000, pp.725-730 https://doi.org/10.1016/S0008-8846(00)00216-7
  2. Lorentz, T and French, C., 'Corrosion of reinforcing steel in concrete:Effects of materials, mix composition, and cracking,' ACI Materials Journal, Vol.92, No.2, March-April, 1995, pp.181-190
  3. Otsuki, N., Miyazato, S., Diola, N., and Suzuki, H., "Influence of bending crack and water-cement ratio on chloride-induced corrosion of main reinforcing bars and stirrups," ACI Materials Journal, Vol.97, No4, July-August, 2000, pp.453~462
  4. Raupach, M., 'Chloride-induced macrocell corrosion of steel in concrete-theoretical background and practical consequences,' Construction and Building Materials, Vol.10, No.5, 1996, pp.329-338 https://doi.org/10.1016/0950-0618(95)00018-6
  5. Kobayashi, K. and Miyagawa, T, 'Numerical analysis of corrosion rate of steel bar suppering from macro-cell corrosion using polarization resistance,' Fourth Int. Con! of Concrete under Severe Conditions of Environment and Loading(Consec04), Vol, 2004, pp.249-256
  6. Schie, P. and Raupach, M. I., 'Laboratory studies and calculatins of the influence of crack width on chloride-induced corrosion of steel in concrete,' ACI Materials Journal, Vol.94, No.1, January-February, 1997, pp.56-62
  7. Treece, R. A. and Jirsa, 1. 0., 'Bond Strength of EpoxyCoated Reinforcing Bars,' ACI Materials. Journal, Vol.86, No.2, March-April, 1989, pp.167-174
  8. Miura, T H. and Itabashi, 1. 1., 'Study on Allowable Coating Damage of Epoxy-Coated Reinforcing Bars,' ACl Materials. Journal, Vol.94, No4, July-August, 1997, pp.267-272
  9. Smith, F. N. and Tullmin, M., 'Using Stainless Steels as Long-Lasting Rebar Material,' Materials Performance, May, 1999, pp.72-76
  10. Rostam, S., 'Reinforced concrete structures-shall concrete remain the dominating means of corrosion prevention?,' Materials and Corrosion, Vol.54, 2003, pp.369=378 https://doi.org/10.1002/maco.200390086
  11. Borges, P. C., Rincon, O. T, Moreno, E. I. and A, A. 'Torres-Acosta, M. Martinez-Madrid, A. Knudsen, Performance of a 60-Year-Old Concrete Pier with Stainless Steel Reinforcement,' Materials Performance, October, 2002, pp.50-55
  12. Tae, S. H., Noguchi, T and Ujiro, T, 'Corrosion Behavior of Cr-bearing Rebar in Concrete with Chloride Ion Content,' Journal of the Architectural Institute of Korea, Vol.7, June, 2005, pp49-54
  13. Japan Concrete Institute, Examination method and criterion about corrosion, corrosion resistance of a concrete construction (plan), JCI-SC1, corrosion evaluation method of steel materials in concrete, 1987, pp.1-2
  14. ASTM C 876-80, Standard test method for half cell potentials of reinforcing steel in concrete, 1981, pp.554~560
  15. Lopez, W. Gonzalez, J. A., and Andrade, C., "Influence of temperature on the service life of rebars," Cement and Concrete Research, Vol.23, 1993, pp.1l30~1140 https://doi.org/10.1016/0008-8846(93)90173-7
  16. Alonso, C. and Andrade, C., 'Effect of nitrite as a corrosion inhibitor in contaminated and chloride-free carbonated mortar,' ACI Materials Journal, Vol.87, No.2, March-April, 1990, pp.130-137
  17. Yamaji, T., Aoyama, T., Yamagawa, M., and Simizu, T., 'Corrosion property of a Stainless steel rebar in the concrete inside,' Proceedings of the Concrete Structure Scenarios JSMS, Kyoto, Vol.31, 2001, pp.69-74. (Japanese)
  18. Erdogdu, S., Bremner, T. W, and Kondratova, 1. L., 'Accelerated testing of plain and epoxy-coated reinforcement in simulated seawater and chloride solutions,' Cement and Concrete Research, Vol.31, 2001, pp.861-867 https://doi.org/10.1016/S0008-8846(01)00487-2
  19. Liu, T. and Weyers, R. W, 'Modeling the dynamic corrosion process in chloride contaminated concrete structures,' Cement and Concrete Research, Vol.28, No.3, 1998,pp.365-379 https://doi.org/10.1016/S0008-8846(98)00259-2
  20. Yalcyn, H. and Ergun, M.,'The prediction of corrosion rates of reinforcing steels in concrete,' Cement and Concrete Research, Vol.26, No.10, 1996, pp.1593-1599 https://doi.org/10.1016/0008-8846(96)00139-1
  21. Arya, C. and Vassie, P. R. W., 'Influence of cathode-toanode area ratio and separation distance on galvanic corrosion currents of steel in concrete,' Cement and Concrete Research, Vol.25, No.5, 1995, pp.989-998 https://doi.org/10.1016/0008-8846(95)00094-S

Cited by

  1. Response of Glass Fiber Reinforced Polymer (GFRP)-Steel Hybrid Reinforcing Bar in Uniaxial Tension vol.11, pp.4, 2017, https://doi.org/10.1007/s40069-017-0212-9