References
- Gowripalan, N., Sirivivatnanon, v., and Lim, C. c., 'Chloride diffusivity of concrete cracked in flexure,' Cement and Concrete Research, Vol.30, 2000, pp.725-730 https://doi.org/10.1016/S0008-8846(00)00216-7
- Lorentz, T and French, C., 'Corrosion of reinforcing steel in concrete:Effects of materials, mix composition, and cracking,' ACI Materials Journal, Vol.92, No.2, March-April, 1995, pp.181-190
- Otsuki, N., Miyazato, S., Diola, N., and Suzuki, H., "Influence of bending crack and water-cement ratio on chloride-induced corrosion of main reinforcing bars and stirrups," ACI Materials Journal, Vol.97, No4, July-August, 2000, pp.453~462
- Raupach, M., 'Chloride-induced macrocell corrosion of steel in concrete-theoretical background and practical consequences,' Construction and Building Materials, Vol.10, No.5, 1996, pp.329-338 https://doi.org/10.1016/0950-0618(95)00018-6
- Kobayashi, K. and Miyagawa, T, 'Numerical analysis of corrosion rate of steel bar suppering from macro-cell corrosion using polarization resistance,' Fourth Int. Con! of Concrete under Severe Conditions of Environment and Loading(Consec04), Vol, 2004, pp.249-256
- Schie, P. and Raupach, M. I., 'Laboratory studies and calculatins of the influence of crack width on chloride-induced corrosion of steel in concrete,' ACI Materials Journal, Vol.94, No.1, January-February, 1997, pp.56-62
- Treece, R. A. and Jirsa, 1. 0., 'Bond Strength of EpoxyCoated Reinforcing Bars,' ACI Materials. Journal, Vol.86, No.2, March-April, 1989, pp.167-174
- Miura, T H. and Itabashi, 1. 1., 'Study on Allowable Coating Damage of Epoxy-Coated Reinforcing Bars,' ACl Materials. Journal, Vol.94, No4, July-August, 1997, pp.267-272
- Smith, F. N. and Tullmin, M., 'Using Stainless Steels as Long-Lasting Rebar Material,' Materials Performance, May, 1999, pp.72-76
- Rostam, S., 'Reinforced concrete structures-shall concrete remain the dominating means of corrosion prevention?,' Materials and Corrosion, Vol.54, 2003, pp.369=378 https://doi.org/10.1002/maco.200390086
- Borges, P. C., Rincon, O. T, Moreno, E. I. and A, A. 'Torres-Acosta, M. Martinez-Madrid, A. Knudsen, Performance of a 60-Year-Old Concrete Pier with Stainless Steel Reinforcement,' Materials Performance, October, 2002, pp.50-55
- Tae, S. H., Noguchi, T and Ujiro, T, 'Corrosion Behavior of Cr-bearing Rebar in Concrete with Chloride Ion Content,' Journal of the Architectural Institute of Korea, Vol.7, June, 2005, pp49-54
- Japan Concrete Institute, Examination method and criterion about corrosion, corrosion resistance of a concrete construction (plan), JCI-SC1, corrosion evaluation method of steel materials in concrete, 1987, pp.1-2
- ASTM C 876-80, Standard test method for half cell potentials of reinforcing steel in concrete, 1981, pp.554~560
- Lopez, W. Gonzalez, J. A., and Andrade, C., "Influence of temperature on the service life of rebars," Cement and Concrete Research, Vol.23, 1993, pp.1l30~1140 https://doi.org/10.1016/0008-8846(93)90173-7
- Alonso, C. and Andrade, C., 'Effect of nitrite as a corrosion inhibitor in contaminated and chloride-free carbonated mortar,' ACI Materials Journal, Vol.87, No.2, March-April, 1990, pp.130-137
- Yamaji, T., Aoyama, T., Yamagawa, M., and Simizu, T., 'Corrosion property of a Stainless steel rebar in the concrete inside,' Proceedings of the Concrete Structure Scenarios JSMS, Kyoto, Vol.31, 2001, pp.69-74. (Japanese)
- Erdogdu, S., Bremner, T. W, and Kondratova, 1. L., 'Accelerated testing of plain and epoxy-coated reinforcement in simulated seawater and chloride solutions,' Cement and Concrete Research, Vol.31, 2001, pp.861-867 https://doi.org/10.1016/S0008-8846(01)00487-2
- Liu, T. and Weyers, R. W, 'Modeling the dynamic corrosion process in chloride contaminated concrete structures,' Cement and Concrete Research, Vol.28, No.3, 1998,pp.365-379 https://doi.org/10.1016/S0008-8846(98)00259-2
- Yalcyn, H. and Ergun, M.,'The prediction of corrosion rates of reinforcing steels in concrete,' Cement and Concrete Research, Vol.26, No.10, 1996, pp.1593-1599 https://doi.org/10.1016/0008-8846(96)00139-1
- Arya, C. and Vassie, P. R. W., 'Influence of cathode-toanode area ratio and separation distance on galvanic corrosion currents of steel in concrete,' Cement and Concrete Research, Vol.25, No.5, 1995, pp.989-998 https://doi.org/10.1016/0008-8846(95)00094-S
Cited by
- Response of Glass Fiber Reinforced Polymer (GFRP)-Steel Hybrid Reinforcing Bar in Uniaxial Tension vol.11, pp.4, 2017, https://doi.org/10.1007/s40069-017-0212-9