Stability Analysis of the Ignition Coil using Partial Discharge

부분방전법을 이용한 점화코일의 안정도 해석

  • Park, Hee-Doo (The Professional Graduate School of Disasters Prevention Technology Samcheok University) ;
  • Kim, Tag-Yong (Department of Electric Engineering, Kwangwoon University) ;
  • Shin, Hyun-Taek (Department of Electric Engineering, Kwangwoon University) ;
  • Kim, Weon-Jong (Department of Electric Engineering, Kwangwoon University) ;
  • Shin, Jong-Yeol (Department of Automobile, Sahmyook College) ;
  • Hong, Jin-Woong (Department of Electric Engineering, Kwangwoon University)
  • 박희두 (삼척대학교 방재기술전문대학원) ;
  • 김탁용 (광운대학교 전기공학과) ;
  • 신현택 (광운대학교 전기공학과) ;
  • 김원종 (광운대학교 전기공학과) ;
  • 신종열 (삼육의명대학 자동차과) ;
  • 홍진웅 (광운대학교 전기공학과)
  • Published : 2006.02.28

Abstract

This paper has been addressed on the discharge characteristics of the ignition coil by Weibull function. It analyzed discharge number and amount of discharge using Weibull distribution to know the inter-relationship between partial discharge and mileage. We detected the discharge which happens for 10 seconds. The applied voltage increased by 0.5[kV] at discharge inception voltage. We diagnosed failure rate using the shape parameters. As a result, we confirmed that the failure rate was increased, because the shape parameter showed the value of 5 according to increasing mileage degradation. Also, it is considered to increase the degradation of inner insulator of ignition coil. Because failure rate of virgin was increased from 0[%] to 25[%] after degradation, stability analysis of the ignition coil using Weibull analysis is possible.

Keywords

References

  1. Barry Hollembeak, 'Automotive Electricity, Electronics & Computer Controls', Delmar pulishers, pp. 331-434, 1999
  2. L.A. Dissado, J.C. Fothergill, 'Electrical Degradation and breakdown in polymers', Peter Peregirinus Ltd. pp. 117-198, 1988
  3. Kuniharu IMAI, 'Statistical Analysis of Tree Propagation from a Simulated Tree Channel with Weibull Distribution and Influence of Temperature on it', T. IEE Japan, Vol. 120-A, No. 5, pp. 645-650, 2000
  4. Kuniharu IMAI, 'Relationship between Diameter of Simulated Tree Channel and Tree Propagation from Its Tip', J. Inst. Electrostate. Japan, Vol. 26, No. 2, pp. 84-90, 2002
  5. T.J. Gallaghe, A.J. Pearmain, 'HIGH VOLTAGE Measurement, Testing and Design', JOHN WILEY & SONS Ltd., pp. 66-72, 1983
  6. K. Imai, K. Ito, N. Shimizu, M. Nawata, 'Influence of Polymer Structure on Tree Growth from a Simulated Tree Channel', 2000 Conference on Electrical Insulation and Dielectric, Vol. 1, pp. 337-340, 2000
  7. J.S. Barrett, M. A. Green, 'A Statistical Method for Evaluating Electrical Failures', IEEE Tran. Power Delivery, Vol. 9, No. 3, pp. 1524-1530, 1994 https://doi.org/10.1109/61.311215
  8. 河村 達雄, 田中 祀捷, '電氣設備の診斷技術', 日本電氣學會, pp. 38-55, 2003
  9. Wu E.Y, Sune. J, Lai W, 'On the Weibull shape factor of intrinsic breakdown of dielectric films and its accurate experimental determination', IEEE Transactions on Electron Devices, Vol. 49, No. 12, pp. 2141-2150, 2002 https://doi.org/10.1109/TED.2002.805603
  10. Wenyuan Li, 'Evaluation Mean Life of Power System Equipment with Limited End-of-Life Failure Data', IEEE Tran. Power Systems, Vol. 19, No. 1, pp. 236-242, 2004 https://doi.org/10.1109/TPWRS.2003.821434
  11. Wendai Wang and Dimitri B. Kececioglu, 'Fitting the Weibull Log-Linear Model to Accelerated Life-Test Data', IEEE Tran. Reliability, Vol. 49, No. 2, pp. 217-223, 2000 https://doi.org/10.1109/24.877341
  12. 山村 昌, '電氣.電子部品の壽命診斷', 日本電氣協會, pp. 45-48, 1999
  13. F. Komori, M. Hikita, Y. Suzuoki, T. Mizutani, 'Study of partial discharge occurrence patterns for construction of degradation diagnosis system', Properties and Applications of Dielectric Materials, Proceedings of the 5th International Conference, pp. 224-227, 1997
  14. Sagias, N.C., Karagiannidis, G.K, 'Gaussian class multivariate Weibull distributions: theory and applications in fading channels', Information Theory, IEEE Transactions on Vol. 51, Issue 10, pp. 3608-3619, 2005 https://doi.org/10.1109/TIT.2005.855598