References
- Thiringer, T., "Power quality measurements performed on a low-voltage grid equipped with two wind turbines", IEEE Transactions on Energy Conversion, Vol. 11, pp. 601-606, Sept. 1996 https://doi.org/10.1109/60.537031
- Coath, G.; Al-Dabbagh, M.; Halgamuge, S.K., "Particle swarm optimisation for reactive power and voltage control with grid-integrated wind farms", Power Engineering Society General Meeting/IEEE, Vol.1, pp. 303-308, June 2004
- Jiang Fan; Salman, S.K., "The effect of integration of wind farms into utility network on voltage control due to the co-ordination of AVC relays", Advances in Power System Control, Operation and Management, APSCOM-97. (Conf. Publ. No. 450), Vol.1, pp.260-265, Nov. 1997
- Papadopoulos, M.P.; Papathanassiou, S.A.; Tentzerakis, S.T.; Boulaxis,N.G., "Investigation of the flicker emission by grid connected wind turbines", 8th International Conference On Harmonics and Quality of Power Proceedings, Vo1.2 , pp. 1152-1157 ,1998
- Fengquan Zhou; Joos, G.; Abbey, C., "Voltage stability in weak connection wind farms", Power Engineering Society General Meeting/IEEE, pp. 610-615, June 2005
- Ha. L.T.; Saha, T.K., "Investigation of power loss and voltage stability limits for large wind farm connections to a subtransmission network", Power Engineering Society General Meeting/IEEE, Vol.2, pp. 2251-2256, June 2004
- Kehrli, A.; Ross, M., "Understanding grid integration issues at wind farms and solutions using voltage source converter FACTS technology", Power Engineering Society General Meeting/IEEE, Vo1.3,pp. 1822-1828, July 2003
- Jorgensen, P.; Tande, J.O.; Vikkelso, A.; Norgard. P.; Christensen, J.S.; Sorenson. P.; Kledal, J.D.; Sondergard, L.. "Power Quatlity and Grid Connection of Wind Turbines", 14th International Conference and Exhibition on CIRED(IEE Conf. Publ. No. 438), Vol.1, Page(s)2.6.1-2.6.6, 1997
- G.C.Paap, F.Jansen, and F.K.A.M.Wiercx, "The Influence of Voltage Sags on The Stability of 10kV Distribution Networks with Large-Scale Dispersed Co-Generation and Wind Generators," CIRED2001, Part 1, CD ROM, June 2001
- Salman, S.K.; Jiang, F.; Rogers, W.J.S., "Effects of wind power generators on the voltage control of utility distribution networks", International Conference on Renewable Energy - Clean Power, pp. 196-201, Nov 1993
- Cartwright, P.; Holdsworth, L.; Ekanayake, J.B.; Jenkins, N., "Co-ordinated voltage control strategy for a doubly-fed induction generator (DFIG)-based wind farm", IEE Proceedings on Generation Transmission and Distribution, Volume 151, Issue 4, pp.495-502 , Jul 2004
- Senjyu, T.; Sueyoshi, N.; Kuninaka, R.; Uezato, K.; Fujita, H.; Funabashi, T., "Study on terminal voltage and power factor control of induction generator for wind power generation system", International Conference on PowerCon 2004, Vol.1, pp.753-758, Nov. 2004
- Palsson, M.P.; Toftevaag, T.; Uhlen, K.; Tande, J.O.G., "Large-scale wind power integration and voltage stability limits in regional networks", Power Engineering Society Summer Meeting, 2002 IEEE, Vol.2, 769, 2002
- Calderaro, V.; Galdi, V.; Raiti, S.; Vaccaro, A., "ICT in distribution networks with wind power generation to improve voltage profiles" Universities Power Engineering Conference 39th, Vol.2, 821, Sept. 2004
- Sanchez, L.F.; Chen, Y.; Chen, G.; Smedley, KM., "A unified voltage quality conditioner for wind power generation" Industry Applications Conference, Vol.1, pp. 579-584, Oct. 2005
- Hyosung Kim, Seung-Ki Sul, "Compensation Voltage Control in Dynamic Voltage Restorers by Use of Feed forward and State Feedback Scheme," IEEE Transaction on Power Electronics, vol.20, No.5, pp. 1169-1177, Sept. 2005 https://doi.org/10.1109/TPEL.2005.854052
- Narend Reddy, "D-VAR and SuperVAR Technology Presentation" , STEP Group Meeting(power point), San Diego, California, American Superconductor, March 08,2004
- Wind turbines connected to grids with voltages below 100kV, Technical Regulations TF3.2.6, Elkraft system, Denmark, May 2004
- Wind turbines connected to grids with voltages above 100kV, Technical Regulations TF3.2.5, Elkraft system, Denmark, December 2004
- Tande. J.O.G., "Impact of wind turbines on voltage quality", 8th International Conference on Harmonics And Quality of Power, vol. 2, pp. 1158 1161, Oct. 1998
- Saccomando. G.; Svensson. J.; Sannino, A., "Improving voltage disturbance rejection for variable-speed wind turbines", IEEE Transactions on Energy Conversion, Vol.17,no.3,pp.422-428, Sept. 2002 https://doi.org/10.1109/TEC.2002.801989
- Morren. J.; de Haan, S.W.H, "Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip", IEEE Transactions on Energy Conversion, Vol. 20, no.2, pp. 435-441, June 2005 https://doi.org/10.1109/TEC.2005.845526
- Senjyu. T.; Kinjo. T.; Uezato. K.; Fujita. H., "Analysis of terminal voltage and output power control of wind turbine generator by series and parallel compensation using SMES", IEEE 35th Annual Power Electronics Specialists Conference, Vol.6, pp. 4278-4284, June 2004
- Sun. T.; Chen. Z.; Blaabjerg, F., "Voltage recovery of grid-connected wind turbines with DFIG after a short-circuit fault". IEEE 35th Annual Power Electronics Specialists Conference, Vol. 3, pp. 1991-1997, June 2004
- Ahmed. T.; Noro, 0.; Matzuo. K.; Shindo. Y.; Nakaoka, M., "Minimum excitation capacitance requirements forwind turbine coupled stand-alone self-excited induction generator with voltage regulation based on SVC", INTELEC '03, pp. 396 403, Oct. 2003
- Muljadi, E.; Yildirim, D.; Batan, T.; Butterfield, C.P., "Understanding the unbalanced-voltage problem in wind turbine generation", Thirty-Fourth IAS Annual Meeting, vol.2, pp. 1359 1365, Oct. 1999
- Brekken, T.; Mohan, N., "A novel doubly-fed induction wind generator control scheme for reactive power control and torque pulsation compensation under unbalanced grid voltage conditions", PESC '03, vol. 2 , pp. 760-764, June 2003