DOI QR코드

DOI QR Code

CFD analysis of ventilation efficiency around an elevated highway using visitation frequency and purging flow rate

  • Huang, Hong (Institute of Industrial Science, The University of Tokyo) ;
  • Kato, Shinsuke (Institute of Industrial Science, The University of Tokyo) ;
  • Ooka, Ryozo (Institute of Industrial Science, The University of Tokyo) ;
  • Jiang, Taifeng (Graduate School of The University of Tokyo)
  • 투고 : 2005.08.09
  • 심사 : 2006.06.09
  • 발행 : 2006.08.25

초록

The concentration of air pollution along roads is higher than the surrounding area because ventilation efficiency has decreased due to the high-density use of space along roads in recent years. In this study, ventilation efficiency around a heavily traffic road covered by an elevated highway and hemmed in along its side by buildings is evaluated using Visitation Frequency (VF, the frequency for pollutant to return to the objective domain) and Purging Flow Rate (PFR, the air flow rate for defining the local domain-averaged concentration). These are analyzed using Computational Fluid Dynamics (CFD) based on the standard $k-{\varepsilon}$ model. The VF and PFR characteristics of four objective domains are analyzed in terms of the changes in wind direction and arrangements of the fencing dividing up and down direction in the road center under the elevated highway. The resulting VFs are more than 1.0 for all cases, which means that pollutants return to the objective domain restricted by the elevated highway and side buildings. The influence of the arrangement of the buildings around the objective domain and the structure in the domain on the VF is substantial. In cases where there are no obstacles under the elevated highway, the local air exchange rate in the domain tends to be improved. Using these indices, the urban ventilation efficiencies between different urban areas can be compared easily.

키워드

참고문헌

  1. Boggs, D. W. and Peterka, J. A. (1989), 'Aerodynamic model tests of tall buildings', J. Eng. Mech., 115, 618-635 https://doi.org/10.1061/(ASCE)0733-9399(1989)115:3(618)
  2. Davidson, L. and Olsson, E. (1998), 'Calculation of age and local purging flow rate in rooms', Building and Environ., 22, 111-127
  3. Fang, X., Jiang, W., Miao, S., Zhang, N., Xu, M., Ji, C., Chen, X., Wei, J., Wang, Z., and Wang, X. (2004), 'The multi-scale numerical modeling system for research on the relationship between urban planning and meteorological environment', Advances in Atmospheric Science, 21, 1, 103-112 https://doi.org/10.1007/BF02915684
  4. Huang, H., Akutsu, Y., Arai, M., and Tamura, M. (2000), 'A two-dimensional air quality model in an urban street canyon: Evaluation and sensitivity analysis', Atmospheric Environ., 34, 689-698 https://doi.org/10.1016/S1352-2310(99)00333-7
  5. Huang, H., Ooka, R., and Kato, S. (2005), 'Urban thermal environment measurements and numerical simulation for an actual complex urban area covering a large district heating and cooling system in summer', Atmospheric Environ., 39, 6362-6375 https://doi.org/10.1016/j.atmosenv.2005.07.018
  6. Hunt, J. C. R., Poulton, E. C., and Mumford, A. (1976), 'The effect of wind on people: New criteria based on wind tunnel experiment', Building and Environ., 2, 15-28
  7. Hwang, S., Ooka, R., Nam, Y., and Sekine, K. (2005), 'The development of geothermal air-conditioning system using ground heat exchange utilizing building's cast-in-place concrete pile foundation (Part 9), development of simulation models base on numerical simulation of soil heat transfer', Summaries of Technical Papers of Annual Meeting of Architectural Institute of Japan, D2, 667-668 (in Japanese)
  8. Ito, K., Kato, S., and Murakami, S. (2000), 'Study of visitation frequency and purging flow rate based on averaged contaminant distribution, study on evaluation of ventilation effectiveness of occupied space in room', J. Archit. Plann. Environ. Eng, AIJ, 529, 31-37 (in Japanese)
  9. Kato, S., Ito, K., and Murakami, S. (2003), 'Analysis of visitation frequency through particle tracking method based on LES and model experiment', Indoor Air, 13, 182-193 https://doi.org/10.1034/j.1600-0668.2003.00173.x
  10. Launder, B. E. and Spalding, D. B. (1974), 'The numerical computation of turbulent flows', Comp. Mech. Eng., 3, 269-289 https://doi.org/10.1016/0045-7825(74)90029-2
  11. Liu, H., Sang, J., Zhang, B., Chan, J. C. L., Cheng, A. Y. S., and Liu, H. (2002), 'Influences of structures on urban ventilation: A numerical experiment', Advances in Atmospheric Science, 19, 6, 1045-1054 https://doi.org/10.1007/s00376-002-0063-3
  12. Mochida, A., Murakami, S., and Shoji, M. (1992), 'Numerical simulation of flow field around texas tech building by large eddy simulation', First International Symposium on Computational Wind Engineering, 16-34
  13. Murakami, S. (1990), 'Numerical simulation of turbulent flow field around cubic model current status and applications of ${\kappa}-{\varepsilon}$ model and LES', J. Wind Eng. Ind. Aerodyn., 33, 139-152 https://doi.org/10.1016/0167-6105(90)90030-G
  14. Murakami, S. Mochida, A., and Hayashi, Y. (1988), 'Modification of production terms in ${\kappa}-{\varepsilon}$ model to remove overestimate of $\kappa$ value around windward comer', 10th Wind Engineering Symposium, 199-204 (in Japanese)
  15. Nicholls, M. E., Peilke, R. A., and Eastman, J. L. (1995), 'Applications of RANS numerical model to dispersion over urban areas', Wind Climate in Cites, K1uwer Academic Publisher, 703-732
  16. Patankar, S. V. (1980), Numerical Heat Transfer and Fluid Flow, McGraw-Hill, New York
  17. Peterka, J. A. (1983), 'Selection of local peak pressure coefficients for wind-tunnel studies of buildings', J. Wind Eng. Ind. Aerodyn., 13, 477-488 https://doi.org/10.1016/0167-6105(83)90166-6
  18. Sandberg, M. (1992), 'Ventilation effectiveness and purging flow rate - A review', International Symposium on Room Air Convection and Ventilation Effectiveness, 1-21
  19. STAR-CD, (2001), 'Methodology, STAR-CD Version 3.15', Computational Dynamics Limited
  20. Takahashi, T., Kato, S., Ooka, R., Kouno, R., and Watanabe, T. (2004), 'Study on prediction of pollutant dispersion on urban area (part 1), wind tunnel study on contaminant diffusion of traffic on existing urban area', Summaries of Technical Papers of Annual Meeting of Architectural Institute of Japan, D2, 815-816 (in Japanese)
  21. World Meteorological Organization (1996), 'Climate and urban development', WMO-No. 844, 256

피인용 문헌

  1. Visualization of city breathability based on CFD technique: case study for urban blocks in Niigata City vol.15, pp.3, 2012, https://doi.org/10.1007/s12650-012-0128-z
  2. Exceedance probability as a tool to evaluate the wind environment of urban areas vol.11, pp.6, 2008, https://doi.org/10.12989/was.2008.11.6.455
  3. Towards the application of indoor ventilation efficiency indices to evaluate the air quality of urban areas vol.43, pp.12, 2008, https://doi.org/10.1016/j.buildenv.2007.11.013
  4. New criteria for assessing local wind environment at pedestrian level based on exceedance probability analysis vol.44, pp.7, 2009, https://doi.org/10.1016/j.buildenv.2008.08.002
  5. Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor vol.45, pp.2, 2011, https://doi.org/10.1016/j.atmosenv.2010.09.048
  6. Indices to evaluate ventilation efficiency in newly-built urban area at pedestrian level vol.112, 2013, https://doi.org/10.1016/j.jweia.2012.11.002
  7. Ventilation efficiency of void space surrounded by buildings with wind blowing over built-up urban area vol.97, pp.7-8, 2009, https://doi.org/10.1016/j.jweia.2009.05.003
  8. City breathability and its link to pollutant concentration distribution within urban-like geometries vol.44, pp.15, 2010, https://doi.org/10.1016/j.atmosenv.2010.02.022
  9. Computational assessment of blockage and wind simulator proximity effects for a new full-scale testing facility vol.13, pp.1, 2006, https://doi.org/10.12989/was.2010.13.1.021
  10. Impact of morphological parameters on urban ventilation in compact cities: The case of the Tuscolano-Don Bosco district in Rome vol.807, pp.p2, 2006, https://doi.org/10.1016/j.scitotenv.2021.150490