소프트콘택트렌즈 착용에 의한 순목 횟수 변화

The Change of Blink Rate by Wearing Soft Contact Lens

  • 이연진 (서울산업대학교 안경광학과) ;
  • 박상일 (서울산업대학교 안경광학과) ;
  • 이흠숙 (서울산업대학교 식품공학과) ;
  • 박미정 (서울산업대학교 안경광학과)
  • Lee, Youn-Jin (Department of Visual Optics, Seoul National University of Technology) ;
  • Park, Sang-Il (Department of Visual Optics, Seoul National University of Technology) ;
  • Lee, Heum-Sook (Department of Food Science and Technology, Seoul National University of Technology) ;
  • Park, Mi-Jung (Department of Visual Optics, Seoul National University of Technology)
  • 투고 : 2006.04.15
  • 발행 : 2006.07.31

초록

소프트콘택트렌즈의 착용시에 나타나는 순목 횟수의 변화를 알아보기 위하여 8종류의 소프트콘택트렌즈를 안질환을 가지고 있지 않는 12명에게 착용시켰다. 8종류의 소프트콘택트렌즈를 착용하고 15분 후의 평균 순목 횟수는 20.0회/분으로 나안의 순목 횟수 13.3회/분보다 통계적으로 유의성있게 증가하였다. 소프트콘택트렌즈 착용 8시간 후에는 24.3회/분으로 나안과 비교하여서는 11회/분, 착용 15분 후와 비교하여서는 4회/분이 증가하였다. 렌즈의 종류에 따른 순목 횟수의 차이가 적어 착용 15분 후의 순목 횟수가 모든 렌즈에서 18.1~20.9회/분의 범위에 있었으며, 착용 8시간 후의 순목 횟수도 22.9~24.9회/분이었다. 중심두께가 얇은 A 렌즈(0.6mm)를 착용시 나안 순목 횟수와 착용 15분 후 순목 횟수의 차이가 10.0~11.9회/분 범위에 있는 착용자가 16.7%로, A 렌즈에 비해 상대적으로 중심두께가 두꺼운 B 렌즈(0.17mm) 및 C 렌즈(0.14mm)보다 더 많았다. 따라서 순목 횟수의 변화는 중심두께만 얇아진다고 해서 감소되는 것은 아니고, 다른 요인들이 종합적으로 작용하여 개인차가 나타날 수 있다는 것을 알 수 있었다. 함수율과 중심두께가 다른 hilafilcon 재질의 B렌즈와 C렌즈의 경우, 8시간 착용으로 일어나는 순목 횟수의 증가 정도가 4.0회/분 이상인 착용자의 비가 각각 58.3% 및 41.7%로 차이가 있었다. 유사한 재질의 렌즈라도 함수율 및 중심두께의 차이에 의해 개인별 순목 횟수에 차이가 있을 수 있음을 알 수 있었다.

We investigated the change of the blink rate by wearing soft contact lens(SCL). Eight types of soft contact lenses were worn by twelve asymptomatic contact lens wearers. When wearers were worn SCLs for 15 min, the average blink rate was 20.0 blinks/min, which was a statistically significant increase compared to 13.3 blinks/min, the average blink rate of non-SCL-worn eye. After 8 hr of lens wear, the average blink rate was 24.3 blinks/min, and it was 11 blinks/min more than that of non-SCL-worn eye and 4 blinks/min more than that of 15 min SCL-worn eye. There were a little difference of the blink rate in types of lens, which the blink rate range of all lens after 15 min of lens wear was 18.1~20.9 blinks/min and that after 8 hr of lens wear was 22.9~24.9 blinks/min. When wearing A lens(vifilcon, 0.06 mm) having thin center thickness, wearers showing difference of 10.0~11.9 blinks/min between non-SCL-worn eye and 15 min SCL-worn eye reached 16.7% and it was more than that of relatively thick B lens(0.17 mm) and C lens(0.14 mm). This result suggest that the center thickness was not unique factor of the blink rate change and other factors would have synthetically influence on the blink rate change. In the case of B lens and C lens of hilafilcon material but having different center thickness and water content, wearers increasing more than 4.0 blinks/min after 8 hr of lens wear was 58.3% and 41.7%, respectively. This result have provided information that the lenses of similar materials but different center thickness and water content could cause individually the different change of the blink rate.

키워드