DOI QR코드

DOI QR Code

Hybrid Damage Monitoring Technique for Bridge Connection Via Pattern-Recognition of Acceleration and Impedance Signals

가속도 및 임피던스 신호의 특징분류를 통한 교량 연결부의 하이브리드 손상 모니터링 기법

  • Published : 2006.12.31

Abstract

This paper presents hybrid structural damage monitoring system which performs both global damage assessment of structure and damage detection of local structural joints. Hybrid damage monitoring system is composed of vibration-based technique and electro/mechanic impedance technique. Vibration-based technique detects global characteristic change ot structure using modal characteristic change of structure, and electro/mechanical impedance technique detects damage existence of local structural joints using impedance change of PZT sensor. For the verification of the proposed hybrid monitoring system, a series of damage scenarios are designed to loosened bolts situations of the structural joints, and acceleration response and impedance response signatures are measured. The proposed hybrid monitoring system is implemented to monitor global damage-state and local damages in structural joints.

본 논문에서는 구조물의 전역적인 손상도 평가와 국부 구조 연결부의 손상 검색을 동시에 수행할 수 있는 하이브리드 구조 손상 모니터링 체계가 제시되었다. 하이브리드 손상 모니터링 체계는 진동기반 기법과 전기/역학적 임피던스 기법으로 구성되었다. 진동기반 기법은 구조물의 모드특징의 변화를 사용하여 구조물의 전역적 특성의 변화를 감지하고, 전기/역학적 임피던스 기법은 PZT 센서의 저항 변화를 사용하여 국부 구조 연결부의 손상 여부를 검출한다. 제안된 하이브리드 모니터링 체계를 검증하기 위해 구조 연결부의 볼트 풀림 상황을 손상 시나리오로 선택하였으며, 가속도 응답과 임피던스 응답 신호가 계측되었다. 실험 결과, 제안된 하이브리드 모니터링 체계를 통해 구조물의 전역적 손상 상태와 국부 구조 연결부의 손상을 정확하게 모니터링 할 수 있었다.

Keywords

References

  1. 윤정방, 이형진, 'System Identification 기법을 이용한 교량의 안전진단방법', 대한토목학회지, 제 45권,2호 1997, pp. 74-82
  2. 김정태, '소수의 고유진동수를 사용하는 비파괴 균열발견모델 의 유도 및 검증', 한국전산구조공학회, 제 12권, 2호, 1999, pp. 140-159
  3. Sohn, H., Farrar, C.R., Hemez, F.M., Shucnk, D.D., Stmemates, D.W. and Nadler, B.R. A Review of Structural Health Monitoring Literature 1996-2001, LA-13976-MS, Los Alamos National Laboratory, Los Alamos. 2003, 301pp
  4. Rytter, A., 'Vibration based inspection of civil engineering,' Ph.D. Dissertation, University of Alborg, Denmark, 1993
  5. Kim, J.T., Ryu, Y.S., Cho, H.M. and Stubbs, N., 'Damage identification in beam-type structures: frequency-based method vs mode-shape-based method,' Engineering Structure, Vol. 25, No. 1, 2003, pp. 57-67 https://doi.org/10.1016/S0141-0296(02)00118-9
  6. Bhalla, S. and Soh, C.K, 'Structural impedance based damage diagnosis by piezo-transducers,' Earthquake Engng Struct. Dyn. Vol. 32, No. 12, 2003, pp. 1897-1916 https://doi.org/10.1002/eqe.307
  7. Kim, J.T. and Stubbs, N., 'Improved damage identification method based on modal information,' Journal of Sound and Vibration, Vol. 252, No.2, 2002, pp. 223-238 https://doi.org/10.1006/jsvi.2001.3749
  8. Giurgiutiu, V. and Zagrai, A.N., 'Embedded self-sensing piezoelectric active sensors for on-line structural identification,' Journal of Vibration and Acoustics-Transactions of ASME, Vol 124, No.1, 2002, pp. 116-125 https://doi.org/10.1115/1.1421056
  9. Giurgiutiu, V. and Zagrai, A.N., 'Damage detection in thin plates and aerospace structures with electro-mechanical impedance method,' Structural Health Monitoring, Vol 4, No.2, 2005, pp. 99-118 https://doi.org/10.1177/1475921705049752
  10. Randall, R. B., Frequency Analysis, Research Studies Press LTD, 1987, 344pp
  11. Craig, R. R., Structural Dynamics, Wiley, New York, 1990, 523pp
  12. Liang, C., Sun, F.P. and Rogers, C.A., 'An impedance method for dynamic analysis of active material system', Journal of Intelligent Material Systems and Structures, Vol. 8, No.4, 1997, pp. 323-334 https://doi.org/10.1177/1045389X9700800405
  13. Zhou, S.W. and Rogers C.A., 'Heat Generation, Temperature, and Thermal Stress of Structurally Integrated Piezo-Actuators,' Journal of Intelligent Material Systems and Structures, Vol. 6, No.3, 1995, pp. 372-379 https://doi.org/10.1177/1045389X9500600308
  14. Park. G., Farrar, C.R., Rutterford, A.C. and Robertson, A.N., 'Piezoelectric active sensor self-diagnostics using electrical admittance measurements,' Journal of Vibration and Acoustics, Vol. 128, No.4, 2006, pp. 469-476 https://doi.org/10.1115/1.2202157
  15. Giurgiutiu, V. and Rogers, C.A., 'Resent advancement in the electro-mechanical impedance method for structural health monitoring and NDE,' Proceedings of the SPIE's 5th International Symposium on Smart Structures and Materials, 1998, pp. 536-547
  16. Giurgiutiu, V., Redmond, J., Roach, D. and Rackow, K., 'Active sensors for health monitoring of aging aerospace structures,' Proceeding of the SPIE's 7th International Symposium on Smart Structures and Material, 2000, pp. 294-305
  17. Park, G., Cudney, H.H. and Inman, D.J. 'Feasibility of using impedance-based damage assessment for pipeline structures,' Earthquake Engineering and Structural Dynamics, Vol. 30, No. 10, 2001, pp. 1463-1474 https://doi.org/10.1002/eqe.72
  18. Park, G., Kabeya, K., Cudney, H.H. and Inman, D.J. 'Impedance-based structural health monitoring for temperature varying applications,' JSME International Journal, Vol. 30, No.2, 2001, pp. 1463-1474
  19. Yi, J.H. and Yun, C.B., 'Comparative study on modal identification methods using output-only information,' Structural Engineering and Mechanics, Vol. 17, No.3, 2004, pp. 445-466 https://doi.org/10.12989/sem.2004.17.3_4.445