Laser Process of Polymer Micro Fluidic Devices

레이저 가공 폴리머 마이크로 유체 장치

  • 김주한 (서울산업대학교 기계공학과)
  • Published : 2006.02.01

Abstract

Polymer micro-fluidic devices were fabricated with laser processes. A UV laser and a femto laser were used to machine polymer micro-fluidic structures directly. This laser direct machining process suits the need of rapid prototyping, as in many applications changes from the original design are often required. As examples, two polymer micro-systems were developed: a micro-check valve and a micro diffuser pump. The micro fluidic devices can be applied for many applications such as clinical diagnostics and drug delivery. Advantages and disadvantages using polymers as a material for micro-fluidic applications are discussed.

Keywords

References

  1. Kancharla, V. and Chen, S., 'Fabrication of biodegradable polymeric micro-devices using laser micromachining,' Biomed. Microdevices., Vol. 4, No. 2, pp. 105 - 109,2002 https://doi.org/10.1023/A:1014679013888
  2. Becker, H. and Locascio, L. E., 'Review Polymer microfluidic devices,' Talanta, Vol. 56, pp, 267 - 287, 2002 https://doi.org/10.1016/S0039-9140(01)00594-X
  3. Jo, B., Lerberghe, L. M., Motsegood, K. M. and Beebe, D. J., 'Three-dimentional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer,' J. Microelectromech. S., Vol. 9, pp.76 - 81,2000 https://doi.org/10.1109/84.825780
  4. Gadre, A. P., Nijdam, A. J., Garra, J. A., Monica, A. H., Cheng, M. C., Luo, C., Srivastava, Y. N., Schneider, T. W., Long, T. J., White, R. C., Paranjape, M. and Currie, J. F., 'Fabrication of a fluid encapsulated dermal patch using multilayered SU-8,' Sensor. Actual. A., Vol. 114, pp. 478 - 485, 2004 https://doi.org/10.1016/j.sna.2004.01.049
  5. Zhao, Y. and Cui, T., 'Fabrication of high- aspect-ratio polymer-based electrostatic comb drives using the hot embossing technique,' J. Micromech. Microeng., Vol. 13, pp. 430 - 435, 2003 https://doi.org/10.1088/0960-1317/13/3/312
  6. Zhou, J. W. L., Chan, H-Y., To, T. K. H., Lai, K. W. C. and Li, W. J., 'Polymer MEMS actuators for underwater micromanipulation,' IEEE/ASME. T. MECHATRONICS., Vol. 9, pp. 334 - 342, 2004 https://doi.org/10.1109/TMECH.2004.828652
  7. Holmes, A. S. and Saidam, S. M., 'Sacrificial layer process with laser-driven release for batch assembly operations,' J. Microelectomech. S., Vol. 7, pp. 416-422, 1998 https://doi.org/10.1109/84.735350
  8. Vaidya, R., Tender, L. M., Bradley, G., O'Brien, M. J., Cone, M. and Lopez, G. P., 'Computer-controlled laser ablation: a convenient and versatile tool for micropatterning biofunctional synthetic surfaces for applications in biosensing and tissue engineering,' Biotechnol. Prog., Vol. 14, pp. 371-377, 1998 https://doi.org/10.1021/bp980039w
  9. Srinivasan, R. and Mayne-Banton, V., 'Self-developing photoetching of poly-ethylene terephthalate films by far-ultraviolet excimer laser radiation,' Appl. Phys. Lett., Vol. 41, pp. 576 - 578, 1982 https://doi.org/10.1063/1.93601
  10. Srinivasan, R. and Braren, B., 'Ultraviolet Laser Ablation of Organic Polymers,' Chem. Rev., Vol. 89, pp. 1303 -1316, 1989 https://doi.org/10.1021/cr00096a003
  11. Dijkkamp, D., Gozdz, A. S. and Venkatesan, T., 'Evidence for the thermal nature of laser-induced polymer ablation,' Phys. Rev. Lett., Vol. 58, pp. 2142 - 2145, 1987 https://doi.org/10.1103/PhysRevLett.58.2142
  12. Kautek, W., Mitterer, S., Kruger, J., Husinsky, W. and Grabner, G., 'Femtosecond-pulse laser ablation of human corneas,' Appl. Phys. A, Vol. 58, pp. 513 - 518, 1994 https://doi.org/10.1007/BF00332446
  13. Katayama, S., Horiike, M., Urairi, M., Hirao, K. and Tsutsumi, N., 'Structure induced in polysilane and thin polysilane layer coated films by irradiation of femto-second laser pulse,' Chem. Phy. Lett., Vol. 373, pp. 140 - 145,2003 https://doi.org/10.1016/S0009-2614(03)00548-7
  14. Kruger, J. and Kautek, W., 'Femtosecond-pulse visible laser processing of transparent materials,' Appl. Surf. Sci., Vol. 96 - 98, pp. 430 - 438, 1996 https://doi.org/10.1016/0169-4332(95)00446-7
  15. Marcinkevicius, A. and Juodkazis, S., 'Femtosecond laser-assisted three-dimensional microfabrication in silica,' Opt. Lett., Vol. 28, pp. 55 - 57, 2003 https://doi.org/10.1364/OL.26.000277
  16. Kruger, J., Martin, S., Madebach, H., Urech, L., Lippert, T., Wokaun, A. and Kautek, W., 'Femto-and nanosecond laser treatment of doped polymethylmethacrylate,' Appl. Surf. Sci., Vol. 247, pp. 406-411, 2005 https://doi.org/10.1016/j.apsusc.2005.01.078
  17. Zugel, S. A., Burke, B. J., Regnier, F. E. and Lytle, F. E., 'Electrophoretically mediated microanalysis of leucine aminopeptidase using two-photon excited fluorescence detection on a microchip,' Anal. Chem., Vol. 72, pp. 5731 - 5735, 2000 https://doi.org/10.1021/ac000801k
  18. Tiren, J., Tenerz, L. and Hok, B., 'A batch-fabricated non-reverse valve with cantilever beam manufactured by micromachining of silicon,' Sensor. Actuat., Vol. 18., pp. 389-396, 1989 https://doi.org/10.1016/0250-6874(89)87044-1
  19. Blevins, R. D., 'Formulas for Natural Frequency and Mode Shape,' Van Nostrand Reinhold Co., pp. 102-103, 1979
  20. Harrison, D. J., Manz, A. and Glavina, P. G., 'Electroosmotic pumping within a chemical sensor system integrated on silicon,' 1991 International Conference on Solid-State Sensors and Actuators, Digest of Technical Papers, TRANSDUCERS '91, pp. 792 - 795, 1991 https://doi.org/10.1109/SENSOR.1991.149002
  21. Stemme, E. and Stemme, G., 'A valveless diffuser/Nozzle-based fluid pump,' Sensor. Actuat. A, Vol. 39, pp. 159-167, 1993 https://doi.org/10.1016/0924-4247(93)80213-Z
  22. Gerlach, T., 'Microdiffusers as dynamic passive valves for micropump applications,' Sensor. Actuat. A, Vol. 69, pp. 181 -191, 1998 https://doi.org/10.1016/S0924-4247(98)00056-9
  23. Olsson, A., Larsson, O., Holm, J., Lundbladh, L., ohman, O. and Stemme, G., 'Valve-less diffuser micropumps fabricated using thermoplastic replication,' Sensor. Actuat. A, Vol. 64, pp. 63-68, 1998 https://doi.org/10.1016/S0924-4247(98)80059-9
  24. Andersson, H., Wijngaart, W., Nilsson, P., Enoksson, P. and Stemme, G., 'A valve-less diffuser micropump for microfluidic analytical systems,' Sensor. Actuat. B, Vol. 72, pp. 259 - 265, 2001 https://doi.org/10.1016/S0925-4005(00)00644-4
  25. Tsai, J. -H. and Lin, L., 'A thermal bubble actuated micro nozzle-diffuser pump,' Proc. of the IEEE Micro Electro Mechanical Systems (MEMS), MEMS 2001, pp. 409 - 412, 2001 https://doi.org/10.1109/MEMSYS.2001.906563