참고문헌
- Garip Y, Gunday M. The use of computed tomography when comparing nickel-titanium and stainless steel files during preparation of simulated curved canals. Int Endod J 34(6):452-457, 2001 https://doi.org/10.1046/j.1365-2591.2001.00416.x
- Baumann MA, Roth A. Effect of experience on quality of canal preparation with rotary nickel-titanium files. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 88(6):714-718, 1999 https://doi.org/10.1016/S1079-2104(99)70015-6
- Schafer E, Schulz-Bongert U, Tulus G. Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study. J Endod 30(6):432-435, 2004 https://doi.org/10.1097/00004770-200406000-00014
- Ove A. Peters. PD Dr med dent, MS FICD. Current Challenges and Concepts in the Preparation of Root Canal Systems : A Review. J Endod 30(8):559-567, 2004 https://doi.org/10.1097/01.DON.0000129039.59003.9D
- Bergmans L, Van Cleynenbreugel J, Beullens M, Wevers M, Van Meerbeek B, Lambrechts P. Progressive versus constant tapered shaft design using NiTi rotary instruments. Int Endod J 36(4):288-295, 2003 https://doi.org/10.1046/j.1365-2591.2003.00650.x
- Clauder T, Baumann MA. ProTaper NT system. Dent Clin North Am 48(1):87-111, 2004 https://doi.org/10.1016/j.cden.2003.10.006
- Schafer E. Shaping ability of Hero 642 rotary nickel-titanium instruments and stainless steel hand K-Flexofiles in simulated curved root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 92(2):215-220, 2001 https://doi.org/10.1067/moe.2001.114622
- Hata G, Uemura M, Kato AS, Imura N, Novo NF, Toda T. A comparison of shaping ability using ProFile, GT file, and Flex-R endodontic instruments in simulated canals. J Endod 28(4):316-321, 2002 https://doi.org/10.1097/00004770-200204000-00014
- Ankrum MT, Hartwell GR, Truitt JE. K3 Endo, ProTaper, and ProFile systems: breakage and distortion in severely curved roots of molars. J Endod 30(4):234-237, 2004 https://doi.org/10.1097/00004770-200404000-00013
- 박완기, 이희주, 허복. 다양한 엔진 구동형 파일의 근관 성형 능력 비교. 대한치과보존학회지 29:1:44-50, 2004
- Qualtrough AJ, Dummer PM. Undergraduate endodontic teaching in the United Kingdom: an update. Int Endod J 30(4):234-239, 1997 https://doi.org/10.1111/j.1365-2591.1997.tb00703.x
- Qualtrough AJ, Whitworth JM, Dummer PM. Preclinical endodontology: an international comparison. Int Endod J 32(5):406-414, 1999 https://doi.org/10.1046/j.1365-2591.1999.00253.x
- Sonntag D, Guntermann A, Kim S.K., Stachniss V. Root canal shaping with manual stainless steel files and rotary Ni-Ti files performed by students. Int Endod J 36(4):246-255, 2003 https://doi.org/10.1046/j.1365-2591.2003.00661.x
- Sonntag D, Delschen S, Stachniww V. Root-canal shaping with manual and rotary Ni-Ti files performed by students. Int Endod J 36(11):715-723, 2003 https://doi.org/10.1046/j.1365-2591.2003.00703.x
- Hanni S, Schonenberger K, Peters OA, Barbakow F. Teaching an engine-driven preparation technique to undergraduates: initial observations. Int. Endod J 36(7):476-482, 2003 https://doi.org/10.1046/j.1365-2591.2003.00677.x
- Calhoun G, Montgomery S. The effects of four instrumentation techniques on root canal shape. J Endod 14(6):273-277, 1988 https://doi.org/10.1016/S0099-2399(88)80025-6
- Kosa DA, Marshall G, Baumgartner JC. An analysis of canal centering using mechanical instrumentation techniques. J Endod 25(6):441-445, 1999 https://doi.org/10.1016/S0099-2399(99)80275-1
- Parashos P, Messer HH. Questionnaire survey on the use of rotary nickel-titanium endodontic instruments by Australian dentists. Int Endod J 37(4):249-259, 2004 https://doi.org/10.1111/j.0143-2885.2004.00784.x
- Yared G, Bou Dagher F, Kulkarni K. Influence of torque control motors and the operator's proficiency on ProTaper failures. Oral Surg Oral Med Oral Pathol Oral Radio Endod 96(2):229-233, 2003 https://doi.org/10.1016/S1079-2104(03)00167-7
- Yared GM, Kulkarni GK. Failure of ProFile Ni-Ti instruments used by an inexperienced operator under access limitations. Int Endod J 35:536-541, 2002 https://doi.org/10.1046/j.1365-2591.2002.00528.x
- Gambarini. G. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. Int Endod J 34:386-389, 2001 https://doi.org/10.1046/j.1365-2591.2001.00259.x
- Szep S, Gerhardt T, Leitzbach C, Luder W, Heidemann D. Preparation of severely curved simulated root canals using engine-driven rotary and conventional hand instruments. Clin Oral Investig 5(1):17-25, 2001 https://doi.org/10.1007/PL00010680
- Yared GM, Dagher FE, Machtou P, Kulkarni GK. Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files. Int Endod J 35(1):7-12, 2002 https://doi.org/10.1046/j.1365-2591.2002.00443.x
- Yared GM, Bou dagher FE, Machtou P. Cyclic fatigue of ProFile rotary instruments after clinical use. Int Endod J 33:204-207, 2000 https://doi.org/10.1046/j.1365-2591.1999.00296.x
- Park SH, Cho KM, Kim JW. The Efficiency of the Ni-Ti Rotary files in Curved Simulated Canals Shaped by Novice Operators. J Kor Acad Cons Dent 28(2):146-155, 2003 https://doi.org/10.5395/JKACD.2003.28.2.146
- Yun HH, Kim SK. A comparison of the shaping abilities of 4 nickel- titanium rotary instruments in simulated root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 95(2):228-233, 2003 https://doi.org/10.1067/moe.2003.92
- Schafer E, Vlassis M. Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canals. Int Endod J 37(4):229-238, 2004 https://doi.org/10.1111/j.0143-2885.2004.00786.x
- 고현정, 백승호, 수종의 Engine driven NiTi file과 stainless steel K-file을 이요한 근관형성 후 근관의 조직형태학적 변화에 관한 연구. 대한치과보존학회지 27:6:612-618, 2002
- Dobo-Nagy C, Serban T, Szabo J, Nagy G, Madlena M. A comparison of the shaping characteristics of two nickel-titanium endodontic hand instruments. Int Endod J 35:283-288, 2002 https://doi.org/10.1046/j.1365-2591.2002.00492.x
- Song YL, Bian Z, Fan B, Fan MW, Gutmann JL, Peng B. A comparison of instrument-centering ability within the root canal for three contemporary instrumentation techniques. Int Endod J 37:265-271, 2004 https://doi.org/10.1111/j.0143-2885.2004.00798.x
- Kim HC, Park JK, Hur B. Relative efficacy of three Ni-Ti file systems used by undergraduates. J Kor Acad Cons Dent 30(1):38-48, 2005 https://doi.org/10.5395/JKACD.2005.30.1.038
- Berutti E, Chiandussi G, Gaviglio I, Ibba A. Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile. J Endod 29(1):15-19, 2003 https://doi.org/10.1097/00004770-200301000-00005