Retentive Force of Adjustable Dental Impression Trays with Different Synthetic Resin Materials

합성수지 재료에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구

  • Lee, In-Seob (Department of Prosthodontics, School of Dentistry, Wonkwang University) ;
  • Lee, jin-Han (Department of Prosthodontics, School of Dentistry, Wonkwang University) ;
  • Kim, Yu-Lee (Department of Prosthodontics, School of Dentistry, Wonkwang University) ;
  • Dong, Jin-Keun (Department of Prosthodontics, School of Dentistry, Wonkwang University)
  • 이인섭 (원광대학교 치과대학 보철학교실) ;
  • 이진한 (원광대학교 치과대학 보철학교실) ;
  • 김유리 (원광대학교 치과대학 보철학교실) ;
  • 동진근 (원광대학교 치과대학 보철학교실)
  • Published : 2006.03.30

Abstract

The adjustable dental impression trays were made for being adjusted their width automatically along the width of patient's dental arch. The purpose of this study was to investigate the retentive force of adjustable dental impression trays made of different synthetic resin materials. Three pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) synthetic resin, polyurethane synthetic resin and polycarbonate synthetic resin with a hole and without a rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray jig which was made for holding the tray on the lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the alginate impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum force by use of UTM at a constant strain rate 100mm per minute. The results obtained in this study were as follows : 1. The upper trays were showed higher retentive force than lower trays in three tray materials. 2. There was no significant difference in the retentive force of the tray materials(p>0.05).

Keywords

Acknowledgement

Supported by : 원광대학교

References

  1. zarb GA, Bolender CL, Hickey JG ,Carlsson GE, Boucher'S Prosthetic Treatment for Edentulous Patients. 10th ed. St Louis : CV Mosby 150-151, 1990
  2. Myers GE, Stockman DG, Factors that affect the accuracy and dimensional stability of the mercaptan rubber-base impression materials. J Prosthet Dent 1960; 10:525-535 https://doi.org/10.1016/0022-3913(60)90016-0
  3. Stackhouse Jr JA. The accuracy of stone dies made from rubber impression materials. J Prosthet 1970;24:377-386 https://doi.org/10.1016/0022-3913(70)90078-8
  4. Shigeto N , Murata H , Hamada T. Evaluation of the methods for dislodging the impression tray affecting the dimensional accuracy of the abutments in a complete dental arch cast. J Prosthet 1989;61:54-58 https://doi.org/10.1016/0022-3913(89)90109-1
  5. Mendez AJ, The influence of impression trays on the accuracy of stone casts poured from irreversible hydrocolloid impressions. J Prosthet Dent 1985;54:383-388 https://doi.org/10.1016/0022-3913(85)90557-8
  6. Eames WE, Sieweke JC, Wallace SW, Rogers LB. Elastomeric impression materials: effect of bulk on accuracy. J Prosthet Dent. 1979;41:304-7 https://doi.org/10.1016/0022-3913(79)90013-1
  7. 송대성, 진태호, 동진근. 한국인 성인에 대한 기성트레이의 적합도에 관한 연구. 대한치과보철학회지 1989;27(2):131-140
  8. 송대성, 강석구, 조혜원, 동진근. 한국형 유치악용 기성 트레이의 개발에 관한 연구. 대한치과보철학회지 1996;34(4);755-779
  9. 신수정, 박정용, 오상천, 동진근. 한국형 유치악용 기성 트레이의 적합도에 관한 연구. Journal of Wonkwang Dental Research Institute 1997;7(1):193-209
  10. Dong JK, Oh SC, Kim MJ. Development of adjustable dental impression trays. 10th Meeting of the International College of Prosthodontists. Halifax, Canada 2003 ; abstract No.51
  11. Jordan LG. Alginate Impression Materials. J Am Dent Assoc 1945;32:985-986 https://doi.org/10.14219/jada.archive.1945.0128
  12. Atkinson HF, Gill HI, and Shepherd RW. Some notes on alginate impression material. Austrailian Dent J 1958;3:184-185 https://doi.org/10.1111/j.1834-7819.1958.tb01835.x
  13. Wilson HJ, Smith DC. The bonding of alginate impression materials to impression trays. Brit Dent J 1963;115:291-294
  14. 송기범, 김성록, 박광수, 김유리, 동진근. 유지형태에 따른 가변형 치과 인상용트레이의 유지력에 관한 연구. 대한치과보철학회지. 2005 :43:15-28
  15. Kaloyannides TM, Orristidou L. Elasticity of impression materials:IV Permanent deformation as a function of time. J Dent Res 1975;54:168-173 https://doi.org/10.1177/00220345750540011401
  16. Morrow RW, Brown Jr CE, Powell JM, Rudd KD. Compatibility of alginate impression materials and dental stones. J Prosthet Dent 1971;25(5):556-566 https://doi.org/10.1016/0022-3913(71)90214-9
  17. 이선형. 고무 인상재의 정확도에 관한 연구. 대한치과의사협회지 1983; 21:237-243
  18. 김경남. 알지네이트 인상재. 대한 치과 기재학회지 1986;13:27-32
  19. Ansari IH. Making a custom tray for elastomiric impression materials without a primary cast. J Prosthet Dent 1994;72(5):569-571 https://doi.org/10.1016/0022-3913(94)90132-5
  20. Milward PJ, Murphy WM. Custom impression trays with a new hypoallergenic material. J Prosthet Dent 1994;72(5):572-573 https://doi.org/10.1016/0022-3913(94)90133-3
  21. Breeding LC, Dixon DL, Moseley JP. Custom impression trays: part l-Mechanical properties. J Prostet Dent 1994;71 :31-34 https://doi.org/10.1016/0022-3913(94)90252-6
  22. 동서문화사. 파스칼 세계대백과사전. 2005
  23. Mitchell JV, Damele JJ. Influence of tray design upon elastic impression materials. J Prosthet Dent. 1970 ;23:51-7 https://doi.org/10.1016/0022-3913(70)90163-0
  24. Reisbick MH, Matyas J. The accuracy of highly filled elastomeric impression materials. J Prothet Dent 1975;33:67-72 https://doi.org/10.1016/S0022-3913(75)80148-X
  25. Phillips RW, Schnell RJ. Diensional stability of rubber base impressions and certain other factors affecting accuracy. J Am Dent Assoc 1958;57:39-48 https://doi.org/10.14219/jada.archive.1958.0248
  26. Linke BA, Nicholls JI, Faucher RR. Distortion analysis of stone casts made from impression materials. J Prostet Dent 1985;54:794-802 https://doi.org/10.1016/0022-3913(85)90473-1
  27. Ciesco JN, Malone WF, Sandrik JL, Mazur B. Comparison of elastomeric impression materials used in fixed prosthodontics. J Prosthet Dent. 1981:45:89-94 https://doi.org/10.1016/0022-3913(81)90018-4
  28. Pagniano RP, Scheid RC, Clowson RL, Dagefoerde RO, Zardiackas LD. Linear dimensional change of acrylic resins used in the fabrication of custom trays. J Prosthet Dent. 1982 ;47:279-8 https://doi.org/10.1016/0022-3913(82)90157-3
  29. Goldfogel M, Harvey WL, Winter D.Dimensional change of acrylic resin tray materials. J Prosthet Dent. 1985 ;54:284-6 https://doi.org/10.1016/0022-3913(85)90306-3
  30. Eames WB, Sieweke JC, Wallace SW, Rogers LB. Elastomeric impression materials: effect of bulk on accuracy. J Prosthet Dent. 1979 ;41:304-7 https://doi.org/10.1016/0022-3913(79)90013-1
  31. Collard EW, Caputo AA, Standlee JP, Trabert KC. Dynamic stresses encountered in impression removal. J Prosthet Dent. 1973;29: 498-506 https://doi.org/10.1016/0022-3913(73)90027-9
  32. de Araujo PA, Jorgensen KD. Effect of material bulk and undercuts on the accuracy of impression materials. J Prosthet Dent. 1985;54: 791-4 https://doi.org/10.1016/0022-3913(85)90472-X
  33. Bomberg TJ, Hatch RA, Hoffman W Jr. Impression material thickness in stock and custom trays. J Prosthet Dent. 1985;54: 170-2 https://doi.org/10.1016/0022-3913(85)90278-1
  34. Fusayama T, Nakazato M. The design of stock trays and the retention of irreversible hydrocolloid impressions. J Prosthet Dent 1969;21:136-142 https://doi.org/10.1016/0022-3913(69)90086-9
  35. Shigeto N, Murata H, Hamada T. Evaluation of the methods for dislodging the impression tray affecting the dimensional accuracy of the abutments in a complete dental arch cast. J Prosthet Dent. 1989;61:54-8 https://doi.org/10.1016/0022-3913(89)90109-1
  36. Johnson GH, Craig RG. Accuracy of addition silicones as a function of technique. J Prosthet Dent. 1986;55: 197-203 https://doi.org/10.1016/0022-3913(86)90342-2
  37. SCHNELL RJ, PHILLIPS RW. Dimensional stability of rubber base impressions and certain other factors affecting accuracy. J Am Dent Assoc. 1958;57:39-48 https://doi.org/10.14219/jada.archive.1958.0248
  38. Walters RA, Spurrier S. An effect of tray design and material retention on the linear dimensional changes in polysulfide impressions. J Prosthet Dent. 1990 ;63:277-81 https://doi.org/10.1016/0022-3913(90)90194-H
  39. Fusayama T, Nakazato M. The design of stock trays and the retention of irreversible hydrocolloid impressions. J Prosthet Dent 1969;21:136-142 https://doi.org/10.1016/0022-3913(69)90086-9
  40. Woodward JD, Morris JC, Khan Z. Accuracy of stone casts produced by perforated trays and nonperforated trays. J Prosthet Dent. 1985 ;53:347-50 https://doi.org/10.1016/0022-3913(85)90508-6
  41. 최민호, 김민정, 오상천, 동진근, 유지형태에 따른 치과 인상용 트레이의 유지력에 관한 연구. 대한치과턱관절기능교합학회지 2004;20(1):43-50