Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and Methods: Metal stock tray and adjustable stock trays were used for 40 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a allginate impressions and allowed to set for one hour. The casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software (CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results: There were no significant differences between the accuracies of the adjustable stock tray and the master model except anterior arch width of the upper arch and the diagonal arch length and arch length(one side) of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study casts produced by them.

Keywords

Acknowledgement

Supported by : 원광대학교

References

  1. Myers GE, Stockman DG. Factors that affect the accuracy and dimentional stability of the mercaptan rubber-base impression materials. J Prosthet Dent 1960; 10:525-535 https://doi.org/10.1016/0022-3913(60)90016-0
  2. Stackhouse JA. The accuracy of stone dies made from rubber impression materials. J Prosthet Dent 1970;24:337-386
  3. Shigeto N, Murata H, Hamada T. Evaluation of the methods for dislodging the impression tray affecting the dimensional accuracy of the abutments in a complete dental arch cast. J Prosthet Dent 1989;61:54-58 https://doi.org/10.1016/0022-3913(89)90109-1
  4. American Dental Association. Vinyl polysiloxane impression materials: a status report. Council on Dental Materials, Instruments, and Equipment. J Am Dent Assoc 1990;120:595-596, 598, 600 https://doi.org/10.14219/jada.archive.1990.0077
  5. Zarb GA, Bergman B, Clayton JA, MacKay HF. Prosthodontic Treatment for partially Edentulous Patients. The C.V. Mosby Co., Louis, 1978
  6. Eames WB, Sieweke JC, Wallace SW, Rogers LB. Elastomeric impression materials: effect of bulk on accuracy. J Prosthet Dent 1979;41:304-307 https://doi.org/10.1016/0022-3913(79)90013-1
  7. Clancy JM, Scandrett FR, Ettinger RL. Long-term dimensional stability of three current elastomers. J Oral Rehabil 1983;10:323-325
  8. Lacy AM, Fukui H, Bellman T, Jendresen MD. Time-dependent accuracy of elastomer impression materials. Part II: Polyether, polysulfides, and polyvinylsiloxane. J Prosthet Dent 1981;45:329-333 https://doi.org/10.1016/0022-3913(81)90400-5
  9. Paul J. Milward LCGI, William M. Murphy. Custom impression trays with a new hypoallergenic material. J Prosthet Dent 1994;72(5):572-573 https://doi.org/10.1016/0022-3913(94)90133-3
  10. 송대성, 강석구, 조혜원, 동진근. 한국형 유치악용 기성트레이의 개발에 관한 연구. J Wonkwang Dental Research Institute 1995;5(3):85-124
  11. 송대성, 진태호, 동진근. 한국인 성인에 대한 기성 tray의 적합도에 관한 연구. 대한치과보철학회지 1989;27(2): 131-140
  12. 신수정, 박정용, 오상천, 동진근. 한국형 유치악용 기성트레이의 적합도에 관한 연구. J Wonkwang Dental Research Institute 1997;7(1):193-209
  13. Dong JK, Oh SC, Kim MJ. Development of adjustable dental impression trays. 10th Meeting of the International College of Prosthodontists, Canada Halifax. 2003:abstract No.51
  14. 엄상호, 오상천. 가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구. 대한치과보철학회지 2005;43(04):453-465
  15. Craig RG.: Restorative Dental Materials. 10th. ed., The C.V. Mosby Co., Louis, 1997
  16. Shillingburg HT, Hatch RA, Keenan MP, Hemphill MW. Impression materials and techniques used for cast restoration in eight states. J Am Dent Assoc 1980;100:696-699 https://doi.org/10.14219/jada.archive.1980.0228
  17. Craig, R.G.: Restorative Dental Materials. 7th. ed., The C.V. Mosby Co., Louis, 1985
  18. Izharul Haque Ansari. Making a custom tray for elastomeric impression materials without a primary cast. J Prosthet Dent 1994:72(5):569-571 https://doi.org/10.1016/0022-3913(94)90132-5
  19. Reiberg HJ. The impression tray - an important factor in impression precision. Int Dent J 1977;27:146
  20. Breeding LC, Dixon DL, Monseley JP. Custom inpression trays part 1 : Mechanical properties. J Prosthet Dent 1994;71:31-34 https://doi.org/10.1016/0022-3913(94)90252-6
  21. 류수인, 장익태, 김광남. 전악인상채득시 인상용 트레이가 경석고 모형의 정확도에 미치는 영향. 대한치과보철학회지 1992;30: 1-13
  22. Millstein P, Maya A, Segura C. Determining the accuracy of stock and custom tray impression/casts. J Oral Rehabil 1998;25:645-648 https://doi.org/10.1046/j.1365-2842.1998.00306.x
  23. Gordon GE, Johnson GH, Drennon DG. The effect of tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent 1990;63:12-15 https://doi.org/10.1016/0022-3913(90)90257-D
  24. Rueda LJ, Sy-Munoz JT, Naylor WP, Goodacre CJ, Swartz ML. The effect of using custom or stock trays on the accuracy of gypsum casts. Int J Prosthodont 1996;9:367-373
  25. Boulton JL, Gage JP, Vincent PF, Basford KE. A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays. Aust Dent J 1996;4:398-404
  26. Brosky ME, Pesun IJ, Lowder PD, DeLong R, Hodges JS. Laser digitization of casts to determine the effect of tray selection and cast formation technique on accuracy. J Prosthet Dent 2002; 87:204-209 https://doi.org/10.1067/mpr.2002.121240
  27. Brosky ME, Major RJ, Delong R, Hodges JS. Evaluation of dental arch reproduction using three-dimensional optical digitization. J Prosthet Dent 2003; 90:434-440 https://doi.org/10.1016/j.prosdent.2003.08.021
  28. Heartwell CM, Modjeski PJ, Mullins EE, Strader KH. Comparison of impression made in perforate and nonperforated rim-lock trays. J Prosthet Dent 1972;27:494-500 https://doi.org/10.1016/0022-3913(72)90261-2
  29. Mendez AJ. The influence of stone casts poured from irreversible hydrocolloid impressions.J Prosthet Dent 1985;54:383-388 https://doi.org/10.1016/0022-3913(85)90557-8
  30. Woodward JD, Morris JC, Zafrulla Khan. Accuracy of stone casts produced by perforated trays an nonperforated trays. J Prosthet Dent 1985;53:347-350 https://doi.org/10.1016/0022-3913(85)90508-6
  31. Valderhaug J. and Floystrand F. : Dimensional stability of elastomeric impression materials in custom-made and stock trays. J Prosthet Dent 1984;52:514-517 https://doi.org/10.1016/0022-3913(84)90336-6
  32. 김인철, 선우양국. 몇 치과 인상재의 flow에 관한 실험적 연구. 대한치과의사협회지 1963;4(1):5
  33. 김철위. 치과용 앨지네이트와 고무인상재의 적합 정밀도에 관한 연구. 대한치과의사협회지 1976;14(5):429
  34. 이선형. 고무인상재의 정확도에 관한 연구. 대한치과의사협회지 1983;21:237-243
  35. Johnson GH, Craig RG. Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models. J Prosthet Dent 1985;53:484-490 https://doi.org/10.1016/0022-3913(85)90630-4
  36. Davis DR, Preble JS. Accuracy of a hydrophilic irreversible hydrocolloid/silicone impression material. J Prosthet Dent 1986;55:304-308 https://doi.org/10.1016/0022-3913(86)90108-3
  37. DeAraujo PA, Jorgensen KD. Effect of material bulk and undercuts on the accuracy of impression materials. J Prosthet Dent 1985;54:791-794 https://doi.org/10.1016/0022-3913(85)90472-X
  38. Anusavice KJ. Phillips' science of dental materials. Elsevier, St Louis 1996, 170
  39. Woodward JD, Morris JC, Kahn Z. Accuracy of stone cast produced by perforated trays and nonperforated trays. J Prosthet Dent 1985;53:347-350 https://doi.org/10.1016/0022-3913(85)90508-6
  40. Kaiser DA, Nicholls JI. A study of distortion and surface hardness of improved artificial stone casts. J Prosthet Dent 1976;36:373-381 https://doi.org/10.1016/0022-3913(76)90157-8
  41. Martinez LJ, von Fraunhofer JA. The effects of custom tray material on the accuracy of master casts. J Prosthodont 1998;7:106-110 https://doi.org/10.1111/j.1532-849X.1998.tb00188.x
  42. Nissan J, Laufer BZ, Brosh T, Assif D. Accuracy of three polyvinyl siloxane putty-wash impression techniques. J Prosthet Dent 2000;83:161-165 https://doi.org/10.1016/S0022-3913(00)80007-4
  43. Valderhaug J, Floystrand F. Dimensional stability of elastomeric impression materials in custom-made and stock trays. J Prosthet Dent 1984;52:514-519 https://doi.org/10.1016/0022-3913(84)90336-6
  44. Dastane A, Vaidyanathan TK, Vaidyanathan J, Mehra R, Hesby R. Development and evaluation of a new 3-D digitization and computer graphic system to study the anatomic tissue and restoration surfaces. J Oral Rehabil 1996;23:25-34 https://doi.org/10.1111/j.1365-2842.1996.tb00808.x
  45. Quick DC, Holton JR, Ross GK. Use of a scanning laser three-dimensional digitizer to evaluate dimensional accuracy of dental impression materials. J Prosthet Dent 1992;68:229-235 https://doi.org/10.1016/0022-3913(92)90319-6
  46. Morrow RW, Brown CE, Powell JM, Rudd KD. Compatibility of alginate impression materials and dental stones. J Prosthet Dent 1971;25:556-566 https://doi.org/10.1016/0022-3913(71)90214-9
  47. Hollinger JO, Lorton L, Krantz WA. Connelly M. A clinical and laboratory comparison of irreversible hydrocollid impression techniques, JProsthet Dent 1984;51:304-309 https://doi.org/10.1016/0022-3913(84)90209-9