References
- Kasemo B, Lausmaa J. Metal selection and surface characteristics. In:Branemark PI, Zarb GA, Albrektsson T(eds), Tissue-integrated prostheses, Osseointegration in clinical dentistry. Quintessence, Chicago, 1985; pp99- 116
- Mcqueen DH. Clinical applications of biomaterials. Advanced in Biomaterials 1982;4:179-185
- Lee MR, Chu YR, Bae TS, Jin YC. A study on the biocompatibility of anodized titanium. Journal of KOSOMOMBE 1993;14:333-339
- Lemons JE. Hydroxyapatite coating. Clin Orthop 1988; 235: 220-223
- Wang BC, Lee TM, Chang E, Yang CY. The shear strength and failure mode of plasma-sprayed hydroxyapatite coating to bone: the effects of coating thickness. J Biomed Mater Res 1993;27:1315-1327 https://doi.org/10.1002/jbm.820271012
- Hayashi K, Inadome T, Mashima T, Sugioka Y. Comparison of bone-implant interface shear strength of soild hydroxyapatite and hydroxyapatite-coated titanium implants. J Biomed Mater Res 1993;27:557-563 https://doi.org/10.1002/jbm.820270502
- Kokubo T, Mijaji F, Kim HM, Nakamura T. Spontaneous apatite formation on chemically surface treated Ti. J Am Ceram Soc 1996;79:1127-1129 https://doi.org/10.1111/j.1151-2916.1996.tb08561.x
- Yan WQ, Nakamura T, Kobayashi M, Kim HM, Mijaji F. Bonding of chemically treated titanium implants to bone. J Biomed Mater Res 1996;37: 267-275 https://doi.org/10.1002/(SICI)1097-4636(199711)37:2<267::AID-JBM17>3.0.CO;2-B
- Kim HM, Mijaji F, Kokubo T, Nakamura T. Bonding strength of bonelike apatite layer to Ti metal substrate. J Biomed Mater Res 1997;38:121-127 https://doi.org/10.1002/(SICI)1097-4636(199722)38:2<121::AID-JBM6>3.0.CO;2-S
- Chung HW, Won DH, Bae TS, Lee MR. Effect of potassium hydroxide treatment of titanium implant on the precipitation of calcium phosphate and tissue compatibility. J Korean Res Soc Dent Mater 2001;28:223-233
- Hanawa T, Ukai H, Murakami K. X-ray photoelectron spectroscopy of calcium-ion- implanted titanium. J Electron Spectrosc 1993;63:347-354 https://doi.org/10.1016/0368-2048(93)80032-H
- Hanawa T, Ukai H, Murakami K, Asaoka K. Structure of surface-modified layers of calciumion-implanted Ti-6AI-4V and Ti-56Ni. Mater Trans JIM 1995;36:438- 444 https://doi.org/10.2320/matertrans1989.36.438
- Hanawa T, Asarni K, Asaoka K. Microdissolution of calcium ions from calcium-ion- implanted titanium. Corros Sci 1996;38:1579-1594 https://doi.org/10.1016/0010-938X(96)00053-4
- Ducheyne P, Van Raemdonck W, Heughebaert JC, Heughebaert M. Structural analysis of hydroxyapatite coating on titanium. Biomaterials 1986;7:97-103 https://doi.org/10.1016/0142-9612(86)90063-3
- Ban S, Maruno S, Harada A, Hattori M, Narita K, Hasegawa J. Effect of temperature on morphology of electrochemically-deposited calcium phosphates. Dent Mater J 1996;15:31-38 https://doi.org/10.4012/dmj.15.31
- Cho KH, Kim MY, Song KY, Bae TS, Lee MH. Effect of electrochemical treatment of titanium on the precipitation of calcium phosphate in a simulated body fluid. J Korean Res Soc Dent Mater 2002;29:263-269
- Ishizawa H, Fujino M, Ogino M. Mechanical and histological investigation of hydrothermally treated and untreated anodic titanium oxide films containing Ca and P. J Biomed Mater Res 1995;29:1459-68 https://doi.org/10.1002/jbm.820291118
- Ishizawa H, Ogino M. Formation and characterization of anodic titanium oxide films containing Ca and P. J Biomed Mater Res 1995a;29:65-72 https://doi.org/10.1002/jbm.820290110
- Ishizawa H, Ogino M. Characterization of thin hydroxyapatite layers formed on anodic titanium oxide films containing Ca and P by hydrothermal treatment. J Biomed Mater Res 1995b;29:1071-1079 https://doi.org/10.1002/jbm.820290907
- Fini M, Cigada A, Rondelli G, Chiesa R, Giardino R, Giavaresi G, Aldini NN, Toricelli P, Vicentini B. In vitro and in vivo behavior of Ca- and P-enriched anodized titanium. Biomaterials 1999;20:1587-1594 https://doi.org/10.1016/S0142-9612(99)00060-5
- Hirata T, Nakamura T, Takashima F, Maruyama T, Taira M, Takahashi J. Studies on polishing of Ag-Pd-Cu-Au alloy with five dental abrasives. J Oral Rehabil 2001;28: 773-777 https://doi.org/10.1046/j.1365-2842.2001.00737.x
- Kawazoe T, Suese K. Clinical Application of titanium crowns. J Dent Med 1989;30:317-328
- Kuroiwa A, Igarashi Y. Application of pure titanium to metal framework. J Jpn Prosthodont Soc 1998;42:547- 558 https://doi.org/10.2186/jjps.42.547
- Cai Z, Shafer T, Watanabe I, Nunn ME, Okabe T. Electrochemical characterization of cast titanium alloys. Biomaterials 2003;24:213-218 https://doi.org/10.1016/S0142-9612(02)00293-4
- Iijima D, Toneyama T, Doi H, Hamanaka H, Kurosaki N. Wear properties of Ti and Ti-6Al-7Nb castings for dental protheses. Biomaterials 2003;24:1519-1524 https://doi.org/10.1016/S0142-9612(02)00533-1
- Hanawa T. Characterization of surface fihns formed on titanium in electrolytic solutions. J Jpn Soc Dent Mater Dev 1989;8:832-844
- Ask M, Lausmaa J, Kasemo B. Preparation and surface spectroscopic characterization of oxide film on Ti-6Al- 4V. Appl Surf Sci 1989;35:283-301 https://doi.org/10.1016/0169-4332(89)90013-5
- Khan M, Williams R, Williams D. The corrosion behaviour of Ti-6Al-4V, Ti-6AI-7Nb and Ti-13Nb-13Zr in protein solutions. Biomaterials 1999;20:631-637 https://doi.org/10.1016/S0142-9612(98)00217-8
- Niinomi M. Fatigue performance and cyto-toxity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr. Biomaterials 2003;24:2673-2683 https://doi.org/10.1016/S0142-9612(03)00069-3
- Sarinnaphakom L, Yoneyama T, Doi H, Kobayashi E, Hamanaka H. Elastic property of Ti-6Al-7Nb alloy castings for removable partial denture. Proceedings of the 5th ISTD, 2oo1;p12
- Nakagawa M, Matsuya S, Udoh K, Ohta M. Development of titanium alloys with high corrosion resistance in fluoride containing solution. Proceedings of the 5th ISTD, 2oo1;p16
- Schreckenbath JP, Marx G. Characterization of anodic spark-converted titanium surfaces for biomedical applications. J Mater Sci: Mater Med 1999;10:453-457 https://doi.org/10.1023/A:1008988706980
- Albrektsson T, Branemark P-I, Hansson HA, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a long lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand 1981;52:155-170 https://doi.org/10.3109/17453678108991776
- Chehroudi B, Gould TRL, Brunette DM. Effect of grooved titanium coated implant surface on epithelial cell behavior in vitro and in vivo. J Biomed Mater Res 1989;23:1067-85 https://doi.org/10.1002/jbm.820230907
- von Recum AF. New aspects of biocompability: Motion at the interface. In: Heimke G, Soltesz U, Lee AJC (eds). Clinical Implant Materials, Advances in Biomaterials vol 9, Elsevier Science Publishers BV, Amsterdam 1990, pp297-302
- Mattsson L, Rolander U. Structure and morphology of anodic oxide films on titanium-preparation technique and electron microscopy. Gothenburg Institute of Physics Resport, No GIPR-264,1985, Goteborg, Sweden
-
Kokubo T, Ito S, Sakka S, Yamamuro T. Formation of a high-strength bioactive glass-ceramic in the system MgO-CaO-
$SiO_2-P_2O_5$ . J Mater Soc 1986;21:536-540 https://doi.org/10.1007/BF01145520 -
Kim KN, Bae TS, So JM. Comparison on the calcium phosphate precipitation of NaOH-treated titanium and bioglass-ceramic CaO-
$P_2O_5$ system. J Korean Res Soc Dent Mater 2001;28:247-252