References
- Shapiro PA, Kokich VG. Uses of implants in orthodontics. Dent Clin North Am 1988;32:539-50
- Roberts WE, Nelson CL, Goodacre CJ. Rigid implant anchorage to close a mandibular first molar extraction site. J Clin Orthod 1994;28:693-704
- Creekmore TD, Eklund MK. The possibility of skeletal anchorage. J Clin Orthod 1983;17:266-9
- Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 1997;31:763-7
- Park HS. The skeletal cortical anchorage using titanium microscrew implants. Korean J Orthod 1999;29:699-706
- Park HS. The use of Micro-implant as orthodontic anchorage. Seoul, Korea: Nare Publication; 2001. p. 5-124
- Park HS, Bae SM, Kyung HM, Sung JH. Micro-implant anchorage for treatment of Skeletal Class I bialveolar protrusion. J Clin Orthod 2001;35:417-22
- Park, HS, Kwon TG, Sung JH. Nonextraction treatment with Microscrew implant. Angle Orthod 2004;74:539-49
- Lee JS, Kim DH, Park YC, Kyung SH, Kim TK. The efficient use of midpalatal miniscrew implants. Angle Orthod 2004;74:711-4
- Chung K, Kim SH, Kook Y. C-orthodontic microimplant for distalization of mandibular dentition in Class III correction. Angle Orthod 2005;75:119-28
- Sowden D, Schmitz JP. AO self-drilling and self-tapping screws in rat calvarial bone: an ultrastructural study of the implant interface. J Oral Maxillofac Surg 2002;60:294-9 https://doi.org/10.1053/joms.2002.30585
- Heidemann W, Gerlach KL, Grobel KH, Kollner HG. Drill free screws: a new form of osteosynthesis screw. J Craniomaxillofac Surg 1998;26: 163-8 https://doi.org/10.1016/S1010-5182(98)80007-3
- Heidemann W, Gerlach KL. Clinical applications of drill free screws in maxillofacial surgery. J Craniomaxillofac Surg 1999;27:252-5 https://doi.org/10.1016/S1010-5182(99)80037-7
- Heidemann W, Terheyden H, Gerlach KL. Analysis of the osseous/metal interface of drill free screws and self tapping screws. J Craniomaxillofac Surg 2001;29:69-74 https://doi.org/10.1054/jcms.2000.0179
- Kerawala CJ, Martin IC, Allan W, Williams ED. The effects of operator technique and bur design on temperature during osseous preparation for osteosynthesis self-tapping screws. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1999;88:145-50 https://doi.org/10.1016/S1079-2104(99)70108-3
- O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res 2004;15:474-80 https://doi.org/10.1111/j.1600-0501.2004.01041.x
- Sennerby L, Thomsen P, Ericson LE. A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. Int J Oral Maxillofac Implants 1992;7: 62-71
- Phillips JH, Rahn BA. Comparison of compression and torque measurements of self-tapping and pre-tapped screws. Plast Reconstr Surg 1989;83:447-58 https://doi.org/10.1097/00006534-198903000-00007
- Trisi P, Rebaudi A. Progressive bone adaptation of titanium implants during and after orthodontic load in humans. Int J Periodontics Restorative Dent 2002;22:31-43
- Roberts WE, Smith RK, Zilberman Y, Mozsary PG, Smith RS. Osseous adaptation to continuous loading of rigid endosseous implants. Am J Orthod 1984;86:95-111 https://doi.org/10.1016/0002-9416(84)90301-4
- Frost HM. Mathematical elements of bone remodeling. Springfield, IL: CC Thomas; 1964
- Hitchon PW, Brenton MD, Coppes JK, From AM, Torner JC. Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws. Spine 2003;28:9-13 https://doi.org/10.1097/00007632-200301010-00004
- Ivanoff CJ, Sennerby L, Lekholm U. Influence of initial implant mobility on the integration of titanium implants: an experimental study in rabbits. Clin Oral Implants Res 1996;7:120-7 https://doi.org/10.1034/j.1600-0501.1996.070205.x
- Schulten AJ, Zimmermann CE, Glowacki J. Osteoclastic bone resorption around intraosseous screws in rat and pig mandibles. Microsc Res Tech 2003;61:533-9 https://doi.org/10.1002/jemt.10376
- Park HS, Jeoung SH, Kwon OH. Factors affecting the clinical success of mini- or microscrew implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2006;130:18-25 https://doi.org/10.1016/j.ajodo.2004.11.032
- Kim JW, Chang YI. Effects of drilling process in stability of micro-implants used for the orthodontic anchorage. Korean J Orthod 2002;32:107-15
- Lohr J, Gellrich NC, Buscher P, Wahl D, Rahn BA. Comparative in vitro studies of self-boring and self-tapping screws. Histomorphological and physical-technical studies of bone layers. Mund Kiefer Gesichtschir 2000;4:159-63 https://doi.org/10.1007/s100060050189
- Eriksson A, Albrektsson T, Grane B, McQueen D. Thermal injury to bone. A vital-microscopic description of heat effects. Int J Oral Surg 1982;11:115-21 https://doi.org/10.1016/S0300-9785(82)80020-3
- Eriksson RA, Adell R. Temperatures during drilling for the placement of implants using the osseointegration technique. J Oral Maxillofac Surg 1986;44:4-7 https://doi.org/10.1016/0278-2391(86)90006-6
- Yacker MJ, Klein M. The effects of irrigation on osteotomy depth and bur diameter. Int J Oral Maxillofac Implants 1996;11:634-8
- Brisman DL. The effects of speed, pressure, and time on bone temperature during the drilling of implant sites. Int J Oral Maxillofac Implants 1996;11:35-7
- Oktenoglu BT, Ferrara LA, Andalkar N, Ozer AF, Sarioglu AC, Benzel EC. Effects of hole preparation on screw pullout resistance and insertional torque: a biomechanical study. J Neurosurg 2001;94:91-6
- Frost HM. A 2003 update of bone physiology and Wolff's Law for clinicians. Angle Orthod 2004;74:3-15