A Study on the Vibration Level of Low Vibration Kinecker

미진동 Kinecker 진동수준에 관한 연구

  • 김희도 (㈜고려노벨화학 기술영업팀) ;
  • 안봉도 (㈜고려노벨화학 기술영업팀) ;
  • 최성현 (㈜고려노벨화학 기술영업팀)
  • Published : 2006.12.30

Abstract

Blast vibrations produced by emulsion explosives, controlled explosives and no vibration Kinecker through test blasting have been analyzed. Test area is mainly composed of andesite of which uniaxial compressive strength is $1,260kg/cm^2$. The empirical scaling formula from a logarithmic plot of peak particle velocity versus scaled distance have been determined and particle velocities with scaled distance have been evaluated for each explosive type. Vibration level of no vibracon KINECKER is lower than one of the controlled vibration blasting by about 30.71% and also lowers than one of the blasting of medium by about 50.94%.

일반 에멀젼폭약과 정밀폭약 및 미진동 Kinecker를 시험 발파하여 각각의 진동 특성을 분석하였다. 시험발파 대상 지역은 안산암이 주종을 이루며, 안산암의 일축압축강도는 $1,260kg/cm^2$로 나타났다. 각 발파패턴별로 시험 발파하여 측정한 진동 자료를 회귀 분석하여 환산거리별 진동속도를 비교한 결과 미진동 Kinecker 발파공법이 정밀진동제어발파보다 평균 30.71%, 진동제어중규모발파보다는 평균 50.94%정도의 진동이 낮게 전파됨을 볼 수 있었다.

Keywords

References

  1. 건설교통부, 2003, 암발파 설계 및 시험발파 잠정지침(안)중 암발파 설계요령, 건설교통부, p. 5
  2. 대한주택공사, 1997, 부산구평지구 대지조성 및 도시기반 시설공사 설계용역 보고서, 대한 주택공사, pp. 15-20
  3. 양형식, 최미진, 2006, 발파진동 추정식의 비교 분석, 2006 대한화약발파공학회 춘계학술발표회, pp. 52-54
  4. 윤철헌, 1996, 최신 화약발파해석, 구미서관, 서울, p. 99