초록
In order to get basic information on the reference electrode material for the long life Al concentration sensor in zinc galvanizing melt, the workability and stability of fluorine potential cell with $CaF_2$ single crystal electrolyte were examined carefully at constant temperature for six kinds of reference materials (Zn, Sn, Cd, Bi, Pb, Al-Sn alloy + fluorides). Good workability and stability of the sensor were found in sensor with $Bi+BiF_3$ reference electrode. The Al sensor with $Bi+BiF_3$ reference electrode was assembled and was tested in Zn-Al melt with different Al concentration. The EMF was changed rapidly with the change of Al concentration and was stabilized in a short time. Thus the response of EMF was satisfactory for $CaF_2$ sensor. The correlationship between EMF from the sensor and logarithm of Al concentration has been derived from the least square regression method. E/mV=57.515log[wt% Al]+1883.3 R=0.9717 ($0.013{\leq}[wt% Al]{\leq}0.984$) The EMF from Al sensor was increased linearly against logarithm of [wt% Al]. The fluorine potential of Zn-Al melt was also calculated to be in the range of $10^{-60}{\sim}10^{-61}$ Pa for the present experiemental condition.