DOI QR코드

DOI QR Code

체내동태 연구를 위한 혈청 중 펜톡시필린의 HPLC 정량법 개발 및 검증

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Pentoxifylline in Human Serum

  • 조혜영 (전남대학교 약학대학 부속 생물학적동등정 및 가교실험연구소, 전남대학교 병원 임상시험센터) ;
  • 강현아 (전남대학교 약학대학 부속 생물학적동등정 및 가교실험연구소, 전남대학교 병원 임상시험센터) ;
  • 류희두 (전남대학교 약학대학 부속 생물학적동등정 및 가교실험연구소, 전남대학교 병원 임상시험센터) ;
  • 이화정 (이화여자대학교 약학대학) ;
  • 문재동 (전남대학교 의과대학) ;
  • 이용복 (전남대학교 약학대학 부속 생물학적동등정 및 가교실험연구소, 전남대학교 병원 임상시험센터)
  • Cho, Hea-Young (Institute of Bioequivalence and Bridging Study, College of Pharmacy, Chonnam National University, Clinical Trial Center, Chonnam National University Hospital) ;
  • Kang, Hyun-Ah (Institute of Bioequivalence and Bridging Study, College of Pharmacy, Chonnam National University, Clinical Trial Center, Chonnam National University Hospital) ;
  • Yoo, Hee-Doo (Institute of Bioequivalence and Bridging Study, College of Pharmacy, Chonnam National University, Clinical Trial Center, Chonnam National University Hospital) ;
  • Lee, Hwa-Jeong (College of Pharmacy Ewha Womans University) ;
  • Moon, Jai-Dong (Medical School, Chonnam National University) ;
  • Lee, Yong-Bok (Institute of Bioequivalence and Bridging Study, College of Pharmacy, Chonnam National University, Clinical Trial Center, Chonnam National University Hospital)
  • 발행 : 2006.04.20

초록

A selective and sensitive reversed-phase HPLC method for the determination of pentoxifylline in human serum was developed, validated, and applied to the pharmacokinetic study of pentoxifylline. Pentoxifylline and internal standard, chloramphenicol, were extracted from the serum by liquid-liquid extraction with dichloromethane and analyzed on a Luna CI8(2) column with the mobile phase of acetonitrile-0.034 M phosphoric acid (25:75, v/v, adjusted to pH 4.0 with 10 M NaOH). Detection wavelength of 273 nm and flow rate of 0.8 mL/min were used. This method showed linear response over the concentration range of 10-500 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of the serum was 10 ng/mL, which was sensitive enough for pharmacokinetic studies of pentoxifylline. The overall accuracy of the quality control samples ranged from 89.3 to 92.7% for pentoxifylline with overall precision (% C.V.) being 4.1-9.2%. The relative mean recovery of pentoxifylline for human serum was 105.8%. Stability (stock solution, short and long-term) studies showed that pentoxifylline was not stable during storage. But three freeze-thaw cycles and extracted serum samples were stable. This method showed good ruggedness (within 15% C.V.) and was successfully applied for the analysis of pentoxifylline in human serum samples for the pharmacokinetic studies of orally administered $Trental^{\circledR}$ tablet (400 mg pentoxifylline), demonstrating the suitability of the method.

키워드

참고문헌

  1. D.M. Aviado and H.R. Dettelbach, Pharmacology of pentoxifylline, a hemorheologic agent for the treatment of intermittent claudication. Angiology, 35(7), 407-417 (1984) https://doi.org/10.1177/000331978403500703
  2. I. Raz, Z. Hussein, E. Samara and J. Ben-David, Comparative pharmcokinetic analysis of novel sustained-release dosage forms of pentoxifylline in healthy subjects, Int. J. Clin. Pharmacol. Ther. Toxicol., 26(5), 246-248 (1988)
  3. USP 26/NF 21, The Official Compendia of Standards Volume , p. 2371 (2003)
  4. 식품의약품안전청 고시 제 2002-60호, 생물학적동등성시험기준 (2002.11.22)
  5. J.W. Wong, K.H. Yuen and K.K. Peh, Simple high-performance liquid chromatographic method for determination of pentoxifylline in human plasma, J. Chromatogr. B, 716, 387-391 (1998) https://doi.org/10.1016/S0378-4347(98)00322-3
  6. G. Musch, T. Hamoir and D.L. Massart, Determination of pentoxifylline and its 5-hydroxy metabolite in human plasma by solid-phase extraction and high performance liquid chromatography with ultraviolet detection, J. Chromatogr., 495, 215-226 (1989) https://doi.org/10.1016/S0378-4347(00)82623-7
  7. A. Mancinelli, S. Pace, A. Marzo and E. A. Martelli, Determination of pentoxifylline and its metabolites in human plasma by high performance liquid chromatography with solid-phase extraction, J. Chromatogr., 575, 101-107 (1992) https://doi.org/10.1016/0378-4347(92)80509-O
  8. R.V. Smith, S.K. Yang, P.J. Davis and M.T. Bauza, Determination of pentoxifylline and its major metabolites in microbial extracts by thin-layer and high-performance liquid chromatography, J. Chromatogr., 23, 281-287 (1983)
  9. $WinNonlin^{TM}$ Users Guide, Ver. 3.0, Pharsight Corp., Mountain View, CA, USA (1998-1999)