DOI QR코드

DOI QR Code

Bioequivalence of Lornocam Tablet to Xefo® Tablet (Lornoxicam 4 mg)

제로 정(로녹시캄 4 mg)에 대한 로노캠 정의 생물학적 동등성

  • Kang, Hyun-Ah (Institute of Bioequivalence and Bridging Study, College of Pharmacy, Chonnam National University, Clinical Trial Center, Chonnam National University Hospital) ;
  • Cho, Hea-Young (Institute of Bioequivalence and Bridging Study, College of Pharmacy, Chonnam National University, Clinical Trial Center, Chonnam National University Hospital) ;
  • Lee, Yong-Bok (Institute of Bioequivalence and Bridging Study, College of Pharmacy, Chonnam National University, Clinical Trial Center, Chonnam National University Hospital)
  • 강현아 (전남대학교 약학대학 부속 생물학적동등성 및 가교시험연구소, 전남대학교 병원임상시험센터) ;
  • 조혜영 (전남대학교 약학대학 부속 생물학적동등성 및 가교시험연구소, 전남대학교 병원임상시험센터) ;
  • 이용복 (전남대학교 약학대학 부속 생물학적동등성 및 가교시험연구소, 전남대학교 병원임상시험센터)
  • Published : 2006.02.20

Abstract

Lornoxicam is a nonsteroidal anti-inflammatory drug that decreases prostaglandin synthesis by inhibiting cyclooxygenase. It has analgesic, antipyretic and antiinflammatory effects. The purpose of the present study was to evaluate the bioequivalence of two lornoxicam tablets, $Xefo^{\circledR}$ (Hyundai Pharmaceutical Ind. Co., Ltd.) and Lornocam (Samchundang Pharmaceutical Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of lornoxicam from the two lornoxicam formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty eight healthy male subjects, $24.39{\pm}1.95$ years in age and $68.63{\pm}7.25$ kg in body weight, were divided into two groups and a randomized $2\;{\time}\;2$ cross-over study was employed. After a single tablet containing 4 mg as lornoxicam was orally administered, blood samples were taken at predetermined time intervals and the concentrations of lornoxicam in serum were determined using HPLC with UV detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t,\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Xefo^{\circledR},$ were -1.56%, 2.16% and -17.12% for $AUC_t,\;C_{max}\;and\;T_{max},$ respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., $log\;0.90{\sim}log\;1.05$ and $log\; 0.88{\sim}log\;1.17$ for $AUC_t\;and\;C_{max},$ respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Lornocam tablet was bioequivalent to $Xefo^{\circledR}$ tablet.

Keywords

References

  1. Lornoxicam, Drugs Fut., 17(8), 683-686 (1992) https://doi.org/10.1358/dof.1992.017.08.179585
  2. Neil M. Skjodt, Neal M. Davies, Clinical pharmacokinetics of lornoxicam, Clin. Pharmacokinet., 34(6), 421-428 (1998) https://doi.org/10.2165/00003088-199834060-00001
  3. S.I. Ankier, A.E. Brimelow, P. Crome, A. Johnston, S.J. Warrington, P. Turner, H.P. Ferber, Chlortenoxicam pharmacokinetics in young and elderly human volunteers, Postgrad. Med. J., 64(756), 752-754 (1988) https://doi.org/10.1136/pgmj.64.756.752
  4. K.T. Olkkola, A.V. Brunetto, M.J. Mattila, Pharmacokinetics of oxicam nonsteroidal anti-inflammatory agents, Clin. Pharmacokinet., 26(2), 107-120 (1994) https://doi.org/10.2165/00003088-199426020-00004
  5. 식품의약청안전청 고시 제 2002-60호, 생물학적동등성시험기준 (2002. 11. 22)
  6. 식품의약청안전청 고시 제 1999-67호, 의약품임상시험관리기준 (2000. 1. 4)
  7. S. Radhofer-Welte, P. Dittrich, Determination of the novel non-steroidal anti-inflammatory drug lornoxicam and its main metabolite in plasma and synovial fluid, J. Chromatography B, 707, 151-159 (1998) https://doi.org/10.1016/S0378-4347(97)00597-5
  8. T. Suwa, H. Urano, Y. Shinohara, J. Kokatsu, Simultaneous high-performance liquid chromatographic determination of lornoxicam and its 5'-hydroxy metabolite in human plasma using electrochemical detection, J. Chromatography, 617(1), 105-110(1993) https://doi.org/10.1016/0378-4347(93)80427-6
  9. Statistical Solutions Ltd., Equiv $Test^{circledR}$ 2.0, U.K. (2001)