DOI QR코드

DOI QR Code

The Performance of Concrete Used High Strength Development Polycarboxylate Superplasticizer

고강도용 폴리카르본산계 고성능 감수제가 사용된 콘크리트의 성능

  • 이완조 (명지대학교 세라믹공학과) ;
  • 강성구 (명지대학교 세라믹공학과) ;
  • 황인동 (세일콘(주) 부설연구소) ;
  • 이재용 (금성개발(주)) ;
  • 박성 (명지대학교 세라믹공학과) ;
  • 정윤중 (명지대학교 세라믹공학과)
  • Published : 2005.03.01

Abstract

There are many kinds of polycarboxylate superplasticizer as a functional classification which are introduced to domestic; Water Reducer, Retention, Ultra High Strength Superplasicizer. These are showed different physical behaviors because of the difference in the chemical system and the manners after cement mixing. In the case of water reducer, when $1.2\% of cement weight used, water reducing which is over $30\% is observed, but it take with segregation and the reduction of slump flow shows over 30 cm after 45 min of concrete produce. In the case of retention, when the same quantity used, water reducing which is about $25\% is observed and slump flow which is up to 45 min shows under 15 cm. And in the case of ultra high strength, when $1.2\% of cement weight used, water reducing which is over $30\% is observed, and slump flow which is up to 45 min recorded fewer than 15 cm. Compressive strength of ultra high strength superplasticizer has take effect of early age strength, and in the condition of specific mixing, 18 h-compressive strength is insured for more than $60\;Kgf/cm^2$ and 24 h-compressive strength is insured for more than $80\;Kgf/cm^2$.

최근 국내에 소개된 폴리카르본산계의 종류는 기능적 분류로 감수용, 유지용, 초고강도용 등으로 소개되고 있으며 이들은 각기 화학적 구조의 차이와 시멘트와 혼합 후 거동의 차이에 의하여 각기 다른 물리적 특성을 보였으며 감수용의 경우 시멘트 중량의 $1.2\%의 사용시 $30\% 이상의 높은 감수율을 보였으나 골재분리를 동반하였으며 콘크리트 제조 후 45분 경과시 슬럼프 플로우의 감소가 약 30cm 이상 발생하였으며 유지용의 경우 롱일 사용량에서 약 $25\% 감수율을 보였으며 45분까지의 슬림프 플로우의 경시 변화는 15cm 이하로 관찰되었다. 초고강도용의 경우 시멘트 중량의 $1.2\%를 사용한 경우 $30\% 이상의 감수율로 관찰되었으며 슬럼프 플로우의 45분 후의 경시변화는 100m 이하로 측정되었다. 압축갔도의 경우 초고강도용의 경우 탁월한 조기 강도 증진 효과를 보였으며 특정배합에서의 18시간 압축강도는 약 $60\;Kgf/cm^2$ 이상이 확보될 수 있었으며 24시간에서 $80\;Kgf/cm^2$이상이 확보될 수 있었다.

Keywords

References

  1. F. J. W. Tang and E. M. Garter, 'Influence of Sulfate Source on Potrland Cement Hydration,' Adv. in Cement Res., 1 [2] 67-74 (1988) https://doi.org/10.1680/adcr.1988.1.2.67
  2. K. Yamada, S. Ogawa, and T. Takahashi, 'Improvement of the Compatibility between Cement and Superplasticizer by Optimizing the Chemical Structure of the Proceedings of the Second International Symposium on Self-Compacting Concrete,' Tokyo, Japan, K. Ozawa and M. Ouchi, Editors, pp. 159-67, 2001
  3. V. S. Ramachandran, 'Influence of Superplasticizers on the Hydration of Cement,' 3rd International, Congress on Polymers in Concrete, Japan, pp. 1071-81, 1981
  4. K. Yamada, S. Ogawa, and S. Hanehara, 'Controlling of the Adsorption and Dispersing Force of Polycarboxylate-Type Superplasticizer by Sulfate Ion Concentration in Aqueous Phase,' Cement and Cone. Res., 31 375-83 (2001) https://doi.org/10.1016/S0008-8846(00)00503-2
  5. Y. C. Tseng, W. L. Wu, H. L. Huang, C. T. Wang, and K. C. Hsu, 'New Carboxylic Aced-Based Superplasticizer for High-Performance Concrete,' Proceedings of the 6th CANMET/ACI Conference on Super plasticizers in Concrete, Nice, France, V. M. Malhotra, Editor, ACI SP-195, pp. 401-12, 2000
  6. S. M. Khalil and M. A. Word, 'Effect of Sulfate Content of Cement on Slump Loss of Concrete Containing High-Range Water Reducers(Superplasticizers),' Magazine of Concrete Research, 32 28-38 (1980) https://doi.org/10.1680/macr.1980.32.110.28
  7. E. Sakai, K. Yamada, and A. Ohta, 'Molecular Structure and Dispersion-Adsorption Mechanisms of Comb-Type Superplasticizers Used in Japan,' J. of Adv. Conc. Tech., 1 [1] 16-25 (2003) https://doi.org/10.3151/jact.1.16