주택에 설치한 온돌 마루 및 붙박이 가구에서 발생하는 휘발성유기화합물의 농도 감소 예측

Prediction of Concentration Decay of Volatile Organic Compounds from Ondol Floor and Furniture

  • 조현 (대림산업주식회사 기술연구소) ;
  • 방승기 (경민대학 실용건축과) ;
  • 백용규 (서일대학 건축과) ;
  • 손장열 (한양대학교 건축대학)
  • 발행 : 2005.03.30

초록

In this study, time-dependent concentration variations of VOCs from fixed furniture and Ondol floor widely used as finishing material of the floor were measured, and prediction equations were developed based on the measured results. VOCs were measured and analyzed based on EPA TO-17 and NIOSH 1500, 1501 method respectively, and GC/FID were used for the analysis of VOCs concentration. Measurements were carried out for 10 days after the installation of furniture and for 40 days after the installation of the floor in the residence constructed more than 10 years ago. In both case of floor and furniture installation, time-dependent concentration decay of VOCs can be properly converted into logarithmic scale. Especially in case of furniture, toluene showed the highest concentration and took longest time to decay. As a result of the prediction of VOCs concentration decay under different air change rate using estimated equations, concentration decay rate of indoor VOCs increased rapidly as the air change rate also increased.

키워드

참고문헌

  1. 방승기, 손장열, 백용규, 조현, 오염물질 방출량 측정챔버 제작 및 경량 칸막이벽의 VOCs 방출특성, 한국생활환경학회지. Vol.11, No.1, 2004.11
  2. 손장열, 이철구, 백용규, 방승기, 조현, 고층아파트에서 환기조건에 따른 실내 VOCs 농도변화에 관한 연구, 대한건축학회 춘계학술발표대회논문집. Vol.22, No.1, 2003.04
  3. ASTM D 5116-97, Small Scale Environmental Chamber Determination of Organic Emissions From Indoor Materials/Products, 1997
  4. ASTM D 6670-01, Standard Practice for Full Scale Chamber Determination of Volatile Organic Emissions from Indoor materials /Products, 2001
  5. EPA, Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air. Compendium Method TO-17, Determination of Volatile Organic Compounds in Ambient Air Using Active Sampling Onto Sorbent Tubes. Second Edition, 1999
  6. NIOSH 1501, Hydrocarbons, Aromatic, NIOSH Manual of Analytical Methods, Forth Edition. 2003