Journal of Industrial Technology (산업기술연구)
- Volume 25 Issue B
- /
- Pages.157-164
- /
- 2005
- /
- 1229-9588(pISSN)
- /
- 1598-1371(eISSN)
Comparison of Bin Averaging Method and Least Square Method for Site Calibration
단지교정을 위한 빈평균방법과 최소자승법의 비교
Abstract
Two methods, the bin averaging method and least square method, are often used in calibrating wind turbine test sites. The objective of this work was to determine a better method to predict the wind speed at wind turbine installing point. The calibration was done at the test site on a complex terrain located in Daegwallyeong, Korea. It was performed for two different cases based on the IEC 61400-12 power performance measurement standard. The wind speeds averaged for 10 minutes ranged between 4 m/s and 16 m/s. The wind-direction bins of each meteorological mast were 10 degrees apart, and only the bins having data measured for more than 24 hours were employed for the test site calibration. For both cases, the two methods were found to yield almost same results which estimated real wind speed very closely.