References
- Architectural Institute of Japan (1996), AIJ Recommendations for Loads on Buildings, Japan.
- Cheung, J.C.K., Palmer, T.R. and Melbourne, W.H. (1993), Aeroelastic Wind Tunnel Model Tests on Tien Ho Commercial Development, Guangzhou, PRC, MEL Consultant Report 14/93, Monash University.
- China National Standard (1987), GBJ9 Load Code for Building Structures, Beijing.
- Davenport, A.G. (1967), "Gust loading factors", J. Struct. Div., ASCE, 93(ST3), 11-34.
- Holmes, J.D. (2001), Wind Loading of Structures, E & FN Spon.
- Islam, M.S. (1988), "Modal coupling and wind-induced vibration of tall building", Ph.D. Dissertation, The John Hopkins University.
- Kareem, A. (1985), "Lateral-torsional motion of tall buildings to wind loads", J. Struct. Eng., ASCE, 111(10), 2479-2496. https://doi.org/10.1061/(ASCE)0733-9445(1985)111:11(2479)
- Kijewski, T. and Kareem, A. (1998), "Dynamic wind effects: a comparative study of provisions in codes and standards with wind tunnel data", Wind and Structures, An Int. J., 1(1), 77-109. https://doi.org/10.12989/was.1998.1.1.077
- Kwok, K.C.S. (1977), "Cross-wind response of structures due to displacement dependent excitations", Ph.D. Thesis, Dept. of Mech. Eng., Monash University.
- Li, Q.S. (2000), "Evaluation of wind-induced vibration of tall buildings and reliability analysis: a case study", Hong Kong Institution of Engineers, Transactions, 7(1), 47-50.
- Li, Q.S., Cao, H. and Li, G. (1994), "Analysis of free vibrations of tall buildings", J. Eng. Mech., ASCE, 120(9), 1861-1876. https://doi.org/10.1061/(ASCE)0733-9399(1994)120:9(1861)
- Li, Q.S., Cao, H. and Li, G. (1996), "Static and dynamic analysis of straight bars with variable cross-section", Comput. & Struct., 59(6), 1185-1191. https://doi.org/10.1016/0045-7949(95)00333-9
- Li, Q.S., Fang, J.Q., Jeary, A.P., Wong, C.K. and Liu, D.K. (2000), "Evaluation of wind effects on a super tall building based on full scale measurements", Earthq. Eng. Struct. Dyn., 29(12), 1845-1862. https://doi.org/10.1002/1096-9845(200012)29:12<1845::AID-EQE995>3.0.CO;2-Q
- Li, Q.S., Xiao, Y.Q., Wong, C.K. and Jeary, A.P. (2004), "Field measurements of typhoon effects on a super tall building", Eng. Struct., 26, 233-244. https://doi.org/10.1016/j.engstruct.2003.09.013
- Li, Q.S., Yang, K., Wong, C.K. and Jeary, A.P. (2003), "The effect of amplitude-dependent damping on windinduced vibrations of s super tall building", J. Wind Eng. Ind. Aerodyn., 91, 1175-1198. https://doi.org/10.1016/S0167-6105(03)00080-1
- Liang, S.G., Li, Q.S., Liu, S.C., Zhang, L.L. and Gu, M. (2003), "Torsional dynamic wind loads on rectangular tall buildings", Eng. Struct., 26, 129-137.
- Liang, S.G., Liu, S.C., Li, Q.S., Zhang, L.L. and Gu, M. (2002), "Mathematical model of acrosswind dynamic loads on rectangular tall buildings", J. Wind Eng. Ind. Aerodyn., 90, 1757-1770. https://doi.org/10.1016/S0167-6105(02)00285-4
- Melbourne, W.H. (1975), "Cross-wind response of structures to wind action", Proceedings of the 4th International Conference on Wind Effects on Buildings and Structures, Cambridge University Press, 343-358.
- National Building Code of Canada (1995), Canadian commission on building and fire codes, Canada.
- Reinhold, T.A. (1977), "Measurement of simultaneous fluctuating loads at multiple levels on a model of a tall building in a simulated urban boundary layer", Ph.D. Thesis, Virginia Polytechnic Institute and State University, Blacksburg, Virginia.
- Solari, G. (1985), "Mathematical model to predict 3-D wind loading on buildings", J. Eng. Mech., ASCE, 111(2), 254-275. https://doi.org/10.1061/(ASCE)0733-9399(1985)111:2(254)
- Tallin, A. and Ellingwood, B. (1984), "Serviceability limit states: wind induced vibrations", J. Struct. Eng., ASCE, 110(10), 2424-2437. https://doi.org/10.1061/(ASCE)0733-9445(1984)110:10(2424)
- Vickery, B.J. and Steckley, A. (1993), "Aerodynamic damping and vortex shedding on an oscillating prism in turbulent shear flow", J. Wind Eng. Ind. Aerodyn., 49, 121-140. https://doi.org/10.1016/0167-6105(93)90009-D
Cited by
- Integrated wind-induced response analysis and design optimization of tall steel buildings using Micro-GA vol.20, pp.8, 2011, https://doi.org/10.1002/tal.569
- Wind-induced lateral-torsional coupled responses of tall buildings vol.11, pp.2, 2008, https://doi.org/10.12989/was.2008.11.2.153
- Spectral characteristics and correlation of dynamic wind forces on a super‐tall building vol.17, pp.2, 2008, https://doi.org/10.1002/tal.364
- Empirical formulations for evaluation of across-wind dynamic loads on rectangular tall buildings vol.16, pp.6, 2013, https://doi.org/10.12989/was.2013.16.6.603
- Wavelet-transform-based damping identification of a super-tall building under strong wind loads vol.19, pp.4, 2014, https://doi.org/10.12989/was.2014.19.4.353
- Application of the high-frequency base balance technique to tall slender structures considering the effects of higher modes vol.151, 2017, https://doi.org/10.1016/j.engstruct.2017.08.005
- Structure Strength Analysis on a Steel Chimney Outer Wall with Three Spiral Guide Plates vol.513-517, pp.1662-7482, 2014, https://doi.org/10.4028/www.scientific.net/AMM.513-517.2625
- A practical combination method for wind-induced responses of high-rise buildings: Based on the correlation of extremes vol.36, pp.None, 2005, https://doi.org/10.1016/j.istruc.2021.12.016