DOI QR코드

DOI QR Code

Characterization of wind-induced vibrations in transmission lines by single-channel field data analysis

  • Yamaguchi, Hiroki (Department of Civil and Environmental Engineering, Saitama University) ;
  • Gurung, Chandra B. (Department of Civil and Environmental Engineering, Saitama University) ;
  • Yukino, Teruhiro (Technical Research Center, Kansai Electric Power Co.)
  • 투고 : 2004.01.13
  • 심사 : 2004.09.21
  • 발행 : 2005.04.25

초록

Wind-induced vibrations measured in the Tsuruga Test Line are characterized in this paper by single-channel data analysis based on piecewise application of Prony's method. Some of events were identified as galloping, while most of events were buffeting responses, which were confirmed partly by the buffeting analysis. Effects of end condition etc. on the response characteristics are also discussed.

키워드

참고문헌

  1. Davenport, A.G. (1962), "Buffeting of suspension bridge by storm winds", J. Struct. Div., ASCE, 88(3), 233-268.
  2. Gurung, C.B., Yamaguchi, H. and Yukino, T. (2001), "Identification of galloping and buffeting in transmission lines", Proceedings of 4th Internatiional Symposium on Cable Dynamics, Montreal, Canada, 211-218.
  3. Gurung, C.B., Yamaguchi, H. and Yukino, T. (2002), "Identification of large amplitude wind-induced vibration of ice-accreted transmission lines based on field observed data", Eng. Struct., 24(2), 179-188. https://doi.org/10.1016/S0141-0296(01)00089-X
  4. Gurung, C.B., Yamaguchi, H. and Yukino, T. (2003), "Identification and characterization of galloping of Tsuruga Test Line based on multi-channel modal analysis of field data", J. Wind Eng. Ind. Aerodyn., 91(7), 903-924. https://doi.org/10.1016/S0167-6105(03)00018-7
  5. Keutgen, R. (1998), "Galloping phenomena a finite element approach", Ph.D. Thesis, University of Liege, Belgium.
  6. Simiu, E. (1974), "Wind spectra and dynamic along wind response", J. Struct. Div., ASCE, 100(9), 1897-1910.
  7. Yamaguchi, H., Xie, X. and Yukino, T. (1997), "Galloping analysis of transmission lines with bundle conductors", Proceedings of 3rd International Symposium on Cable Dynamics, Trondheim, Norway, 61-66.
  8. Yukino, T., Fujii, K. and Hayase, I. (1995), "Galloping phenomena of large bundle conductors observed on the full-scale test line", Proceedings of 1st International Symposium on Cable Dynamics, Liege, Belgium, 557-563.
  9. Yukino, T. and Kuze, T. (2001), "Vibration characteristics in the long span 4 bundled conductors of transmission line", Proceedings of 5th Asia-Pacific Conference on Wind Engineering, Kyoto, Japan, 193-196.

피인용 문헌

  1. Dynamic Responses and Vibration Control of the Transmission Tower-Line System: A State-of-the-Art Review vol.2014, 2014, https://doi.org/10.1155/2014/538457
  2. Full Scale Experiment for Vibration Analysis of Ice-Coated Bundled-Conductor Transmission Lines vol.26, pp.1, 2022, https://doi.org/10.1007/s12205-021-0814-2