References
- AISC (1989), Manual of Steel Construction: Allowable Stress Design, 9th Edition, American Institute of Steel Construction, Chicago, III
- AISC (2001), Manual of Steel Constrnction: Load and Resistance Factor Design (LRFD), 3rd Edition, American Institute of Steel Construction, Chicago, III
- Aristizabal-Ochoa, J.D. (1997), 'Storey stability of braced, partially braced, and unbraced frames: Classical approach,' J. Struct. Eng., ASCE, 123(6), 799-806 https://doi.org/10.1061/(ASCE)0733-9445(1997)123:6(799)
- Bjorhovde, R. (1984), 'Effect of end restraint on column strength - Practical applications', Eng J., AISC, 21(1), 1-13
- Bridge, R.Q. and Fraster, D.J. (1987), 'Improved G-factor method for evaluating effective lengths of column', J. Struct. Eng, ASCE, 113(6), 1341-1356 https://doi.org/10.1061/(ASCE)0733-9445(1987)113:6(1341)
- Chen, W.F. and Lui, E.M. (1987), Structural Stability - Theory and Implication, Elsevier Science Publishing Co., Inc., New York
- Duan, L. and Chen, W.F. (1989), 'Effective length factor for columns in unbraced frames', J. Struct. Eng., ASCE, 115(1), 149-165 https://doi.org/10.1061/(ASCE)0733-9445(1989)115:1(149)
- Julian, O.G. and Lawrence, L.S. (1959), Notes on J and L nomographs for determination of effective lengths, Unpublished Report
- LeMessurier, W.J. (1977), 'A practical method of second order analysis, Part 2-rigid frame', Eng. J., AISC, 14(2), 49-67
- Livesley, R.K. (1975), Matrix Methods of Structural Analysis, 2nd Ed., Pergamon Press Ltd., Headington Hill Hall, Oxford
- Lui, E.M. (1992), 'A novel approach for K factor determination', Eng. J., AISC, 29(4), 150-159
- Majid, K.I. (1972), Non-Linear Structures, Butterworth & Co. Ltd.
- Roddis, W.M.K., Hamid, H.A. and Guo, C.Q. (1998), 'K factor for unbraced frames: Alignment chart accuracy for practical frame variations', Eng. J., AISC, 35(3), 81-93
- Shanmugam, N.E. and Chen, W.F. (1995), 'An assessment of K factor formulas', Eng. J., AISC, 32(1), 3-11
- Xu, L. and Liu, Y. (2002), 'Storey-based effective length factors for unbraced PR frames', Eng. J., AISC, 39(1), 13-29
- Xu, L., Liu, Y. and Chen (2001), 'Stability of unbraced frames under non-proportional loading', Struct. Eng. Mech., 11(1), 1-16 https://doi.org/10.12989/sem.2001.11.1.001
- Yura, J.A. (1971), 'The effective length of column in unbraced frame', Eng. J., AISC, 8(2), 37-42
Cited by
- Storey-based stability of unbraced steel frames at elevated temperature vol.78, 2012, https://doi.org/10.1016/j.jcsr.2012.06.010
- Effective buckling length of steel column members based on elastic/inelastic system buckling analyses vol.26, pp.6, 2007, https://doi.org/10.12989/sem.2007.26.6.651
- System buckling analysis for multi-story frames subjected to nonconservative forces vol.15, pp.2, 2015, https://doi.org/10.1007/s13296-015-6003-8
- Hybrid-member stiffness matrix accounting for geometrical nonlinearity and member inelasticity in semi-rigid frameworks vol.31, pp.12, 2009, https://doi.org/10.1016/j.engstruct.2009.07.014
- A numerical method for buckling analysis of built-up columns with stay plates vol.26, pp.4, 2007, https://doi.org/10.12989/sem.2007.26.4.441
- Exact buckling load of a restrained RC column vol.27, pp.3, 2007, https://doi.org/10.12989/sem.2007.27.3.293
- Improving the Reliability of Measuring Critical Buckling Load in Sway Mode Frames vol.56, pp.2, 2016, https://doi.org/10.1007/s11340-015-0098-x
- Stochastic finite element analysis of structural systems with partially restrained connections subjected to seismic loads vol.9, pp.6, 2009, https://doi.org/10.12989/scs.2009.9.6.499
- Seismic Performance and Storey-Based Stability of Suspended Buildings vol.17, pp.10, 2014, https://doi.org/10.1260/1369-4332.17.10.1531
- Storey-based column effective length factors with accounting for initial geometric imperfections vol.30, pp.12, 2008, https://doi.org/10.1016/j.engstruct.2008.05.015
- Stability of multi-storey unbraced steel frames subjected to variable loading vol.63, pp.11, 2007, https://doi.org/10.1016/j.jcsr.2007.01.010
- Buckling of restrained steel columns due to fire conditions vol.8, pp.2, 2005, https://doi.org/10.12989/scs.2008.8.2.159
- Semi-rigid connection modeling for steel frameworks vol.35, pp.4, 2005, https://doi.org/10.12989/sem.2010.35.4.431
- Storey-based stability of unbraced steel frames under piece-linear temperature distributions vol.194, pp.None, 2019, https://doi.org/10.1016/j.engstruct.2019.05.064
- Story-Based Stability of Multistory Steel Semibraced and Unbraced Frames with Semirigid Connections vol.147, pp.1, 2005, https://doi.org/10.1061/(asce)st.1943-541x.0002874
- Tensile Buckling of a Rod with an End Moving along a Circular Guide: Improved Experimental Investigation Based on a Dynamic Approach vol.11, pp.16, 2005, https://doi.org/10.3390/app11167277
- Analysis and verification of cable pretension effect on the buckling load of a single-link flexible mechanism vol.104, pp.None, 2005, https://doi.org/10.1016/j.apm.2021.11.034