In this paper, we studied resolution to the FBP(Filtered Back-Propagation) tomographic image reconstruction algorithms. In order to analyze the resolution to the tomographic images, we derived ambiguity function to this algorithm which can be reconstructed from the improved FBP image reconstruction algorithm by using fixed coordinate system practically. Through simulation using this function, we determined the lateral and depth resolution quantitively and then analyzed respectively. Simulation results show that the lateral and depth resolution to the improved FBP image reconstruction algerian was determined $0.27\lambda\;and\;0.70\lambda$ at the 3dB, and also $0.89\lambda\;and\;0.96\lambda$ at the 6dB respectively. This results proved that improved FBP reconstruction algorithms for diffraction tomography of incident planar wave is useful to developed the tomographic image system, analyze the resolution to the tomographic images, we derived ambiguity function to this algerian which can be reconstructed from the improved FBP image reconstruction algorithm by using fixed coordinate system.

본 논문은 토모그라픽 영상시스템에 적합한 FBP 토모그라픽 영상복원 알고리즘의 분해능에 관하여 연구하였다. 고정좌표계를 이용하는 개선된 FBP 토모그라픽 영상복원 알고리즘으로부터 분해능을 분석할 수 있는 모호함수를 유도하였고, 이를 이용한 모의실험을 통하여 얻은 진폭분포로부터 측방향 및 축방향 분해능을 정량적으로 결정하였다. 개선된 FBP 토모그라픽 영상복원 알고리즘을 통해 기존의 SAM(Scanning Acoustic Microscope)시스템으로부터 얻을 수 있는 3dB와 6dB 축방향 분해능에 대해서도 각각 0.70 파장과 0.96 파장으로 SAM 영상의 3dB 축방향 분해능인 7 파장에 비하여 매우 개선된 분해능을 얻을 수 있음을 확인하였다. 평면 입사파의 회절 토모그라픽 영상복원을 위한 개선된 FBP 토모그라픽 영상복원 알고리즘은 미세하고 복잡한 다층 박막구조를 갖는 시료에 대하여 좋은 분해능을 갖는 토모그라픽 영상시스템을 개발하는데 유용하게 활용할 수 있도록 하였다.

Keywords