DOI QR코드

DOI QR Code

손동작에 따른 손체표 길이 변화를 적용한 장갑 설계 평가

Evaluation of Glove Designs Applying Change in Hand Length Dimensions by Hand Motion

  • 권오채 (삼성전자 무선통신사업부) ;
  • 선미선 (한국국방연구원 자원관리연구센터) ;
  • 정기효 (포항공과대학교 기계산업공학부) ;
  • 이민정 (포항공과대학교 기계산업공학부) ;
  • 연수민 (경북대학교 의류학과) ;
  • 유희천 (포항공과대학교 기계산업공학부) ;
  • 김희은 (경북대학교 의류학과)
  • 발행 : 2005.11.30

초록

Use of a glove made of materials with a low elasticity decreases the performance of the hand such as agility, dexterity, range of motion, and grip strength. The present study examined if the adverse effects of a low-elastic glove can be reduced by a design which accommodates the changes of hand surface lengths by hand motion. Two glove designs which provide patches of elastic cloth and pleats at the finger joints and knuckle were developed by considering the hand surface length changes, and then compared with two conditions(bare hand and conventional glove design that does not consider the dynamic characteristics of the hand dimensions) in terms of completion time in peg board insertion task, maximum grip strength, discomfort in hand motion, discomfort in force exertion, and overall discomfort by 24 right-handed participants. The test results confirmed that wearing of a glove significantly reduced the agility and grip strength capability of the hand and indicated that the novel designs were effective to lessen the performance decreases compared to the conventional design. Also, of the glove designs, the pleat glove design was found most preferred for both better hand performance and less subjective discomfort.

키워드

참고문헌

  1. 권오채, 정기효, 선미선, 유희천, 김희은, 손측정 변수들간의 연관성 분석을 이용한 장갑 설계의 중요 변수 결정 및 장갑 치수 체계 적용. 대한인간공학회지, 23(3), 25-38, 2004
  2. 선미선, 권오채, 이민정, 정기효, 연수민, 유희천, 김희은, 장갑 설계 적용을 위한 손동작에 따른 손체표의 길이 변화율 측정. 대한인간공학회, 추계학술대회지, 2004
  3. 한국표준과학연구원, 산업제품의 표준치 설정을 위한 국민표준체위 조사 보고서. 국립기술품질원, 1997
  4. Adams, S. K., and Peterson, P. J., Maximum voluntary hand grip torque for circular electrical connectors. Human Factors, 30(6), 733-745, 1988 https://doi.org/10.1177/001872088803000609
  5. Batra, S., Bronkema, L. A., Wang, M. J., and Bishu, R. R., Glove attributes: Can they predict performance? International Journal of Industrial Ergonomics, 14, 201-209, 1994 https://doi.org/10.1016/0169-8141(94)90096-5
  6. Bellinger, T. A., and Slocum, A. C., Effect of protective gloves on hand movement: An exploratory study. Applied Ergonomics, 24(4), 244-250, 1993 https://doi.org/10.1016/0003-6870(93)90458-L
  7. Bensel, C. K., The effect of various thicknesses of chemical protective gloves on manual dexterity. Ergonomics, 36(6), 687-696, 1993 https://doi.org/10.1080/00140139308967930
  8. Borg, G., Borg's Perceived Exertion and Pain Scales. Champaign: Human Kinetics, 1998
  9. Caldwell, L. S., Chaffin, D. B., Dukes-Dobos, F. N., Kroemer, K. H. E., Laubach, L. L., Snook, S. H., and Wasserman, D. E., A proposed standard procedure for static muscle strength testing. American Industrial Hygiene Association Journal, 35(4), 201-206, 1974 https://doi.org/10.1080/0002889748507023
  10. Greiner, T. M., Hand Anthropometry of U.S. Army Personnel. U.S. Army Natick Research, Development and Engineering Center. Natick: MA. (NTIS No. ADA244533), 1991
  11. Muralidhar, A., Bishu, R. R., and Hallbeck, M. S., The development and evaluation of an ergonomic glove. Applied Ergonomics, 30(6), 555-563, 1999 https://doi.org/10.1016/S0003-6870(99)00005-8
  12. Nelson, J. B., and Mital, A., An ergonomic evaluation of dexterity and tactility with increase in examination/surgical glove thickness. Ergonomics, 38, 723-733, 1995 https://doi.org/10.1080/00140139508925144
  13. Tsaousidis, N., and Freivalds, A., Effect of gloves on maximum force and the rate of force development in pinch, wrist flexion and grip. International Journal of Industrial Ergonomics, 21(5), 353-360, 1998 https://doi.org/10.1016/S0169-8141(96)00086-8
  14. You, H., Kumar, A., Young, R., Veluswamy, P., and Malzahn, D. E., An ergonomic evaluation of manual Cleco plier designs: Effects of rubber grip, spring recoil, and worksurface angle. Applied Ergonomics, 36, 575-583, 2005 https://doi.org/10.1016/j.apergo.2005.01.014