Design of Magneto-Rheological Fluid Based Device


초록

The effect of power supply voltage on the performance limits in a laboratory magneto-rheological fluid based device was identified by experiments. It suggests that the frequency range of motion for control is limited by the voltage attenuation due to the coil inductance and the maximum power supply voltage set for practical use of an MRF devices. In this work, the magnetic and electrical characteristics of the MRF device are investigated and a design procedure is formulated to achieve the desired performance for a given power supply.

키워드

참고문헌

  1. Ahn, Y. K., Morishita, S.and Yang, B. S., 1998, 'Directionally Controllable Squeeze Film Damper Using Liquid Crystal,' KSME International Journal, Vol. 12, No. 6, pp. 1097-1103
  2. Carlson, J. D., Chrzan, M. J. and James, F. O., 1994, 'Magnetorheological Fluid Devices,' U. S. Patent #5284330
  3. Carlson, J. D., Catanzarite, D. M. and St. Clair, K. A., 1996, 'Commercial Magneto-Rheological Fluid Devices,' Proceedings of 5th International Conference on Electro-Rheological Fluids, Magneto-Rheological Suspensions and Associated Thchnology. pp. 20-28
  4. Choi, S. B. and Choi, Y. T., 1999, 'Sliding Mode Control of a Shear-Mode Type ER Engine Mount,' KSME International Journal, Vol. 13, No. 1, pp. 26-33
  5. Duclos, T. G., 1988, 'Design of Devices Using Electrorheological Fluid, Society of Automotive Engineering,' SAE Paper #881134
  6. Jung, B. B. and Park, Y., 1998, 'Electronically Controlled Power Steering by Magneto Pheological Fluid,' Proceedings of the 13th Korea Automatic Control Conference, pp. 1173-1176
  7. Jung, B. B. and Park, Y., 1999, 'Development of Damper for Electronically Controlled Power Steering by Magneto-Rheological Fluid,' Proceedings of the KSAE Spring Conference, pp. 587-591
  8. Kim, J. H., Lee, C. W. and Lee, S. K., 1996, 'Modelling of Magneto-rheological Fluid Based Semi-active Mount,' Proceedings of 3rd International Conference on Motion and Vibration Control, Vol. 3, pp. 164-169
  9. Lord Material Division, November 1999, 'Magnetic Circuit Design,' Engineering Note
  10. Lord Materials Division, December 1999, 'Designing with MR Fluids,' Engineering Note
  11. Maslen, E., Hermann, P., Scott, M. and Humphris, R. R., 1989, 'Practical Limits to the Performance of Magnetic Bearings: Peak Force, Slew Rate, and Displacement Sensitivity,' Transactions of ASME, Journal of Tribology, Vol. 111, pp. 331-336
  12. Rankin, P. J., Ginder, J. M. and Klingenberg, D. J., 1998, 'Electro- and Magneto-rheology,' Current Optinion in Colloid & Interface Science, Vol. 3, pp. 373-381
  13. Weiss, K. D., Duclos, T. G., Carlson, J. D., Chrzan, M. J. and Margida, A. J., 1993, 'High Strength Magneto- and Electro-rheological Fluid,' SAE Paper #932451