This study was conducted to evaluate the grit removal efficiency of tornado block-type vortex grit separator. Vortex grit separator was manufactured for this study, and it was characterized by the impeller and tornado block installed in separator. Impeller was installed to increase water velocity in the separator and tornado block was installed to increase the grit lifting efficiency. Pilot study was also conducted in A sewage treatment plant (STP) in Gyeonggi province from November 2003 to May 2004 (64 days). Major findings are as follows. 1. Impeller was proven to increase water velocity in the grit separator, especially in low flow rate. This influence will increase separation ratio of organics from grits, preventing those organics from sedimentation. 2. Sand (with 0.2~0.3mm size) removal efficiency was over 98 % and 96 %, at the flow rate of $500m^3/day$ and $750m^3/day$ under the condition that impeller rotation velocity kept at 15 rpm. Originally that grit separator was designed to have the capacity of $500m^3/day$. $750m^3/day$ was tried to investigate the performance of this type of grit separator under overload condition. Stable grit removal was still available to the extent of 150% of designed capacity. 3. It took less than 3 minutes for the grit separator to completely lift out 3 kgs of 0.2-0.3 mm sized, settled sand at the bottom to 2,060 mm high above water surface. But it showed the tendency to spend a little more time on lifting the grit as the grit size and the vertical height of the lift increased. 4. During experimental duration in A STP, it was found that the average amount of inlet grit was about 981 g/day (160~1,685 g/day) under $500m^3/day$ of operation condition, but it varied so severely during the experimental duration. After classification of discharged grit according to its size, grit with 0.3-0.42 mm size was found as largest part of output.

Keywords

References

  1. 환경부 (1998) 하수도시설기준
  2. 염철민, 신경무, 박노연 (2004) 하수처리장에서 수력학적 와류형 분리장치를 이용한 침사제거, 상하수도학회지, 18(2), pp 94-98
  3. Andoh, R.Y.G. and Harper, I. (1993) The $Swirl-FIo^{TM}$ Process for High Rate Physico-Chemical Treatment at Wastewater Treatment Works. London: Hydro Research and Development Ltd. Publications
  4. Andoh, R.Y.G. and Smission, R.P.M. (1994) High Rate Sedimentation in Hydrodynamic Separafors. In Proceedings of the 2nd international Conference on Hydraulic Modeling Development and Application of Physical and Mathematical Models, Stratford, UK, pp. 341-358
  5. Andoh, R.Y.G. (1998) Improving Environmental Quality Using Hydrodynamic Vortex Separafors. Water Quality International. January/February
  6. Brombach, H. (1992) Solids Removal from Combined Sewer Overflows with Vortex Separafors. In International Conference on Innovative Technologies in the Domain of Urban Sform Drainage, NOVATEC 92, Lyon, France
  7. Brombach, H., Xanthopoulos, C., Hahn, H.H., and Pisano, W.C. (1993) Experience with Vortex Separafors for Combined Sewer Overflow Control. Wat. Sci. Tech., 27(5-6), pp. 93-104
  8. Fagan, G.W. (1993) A Quality Assessment of Dynamic Experiences: the UK experience. In International Conference on Urban Sform Drainage (lCUSD)
  9. Gardner, P. and Deamer, A. (1996) An Evaluation of Methods for Assessing the Removal Efficiency of a Grit Separation Device, Wat. Sci. Tech., 33(9), pp. 269-275
  10. Hedges, P.D. (1991) The Performance of the Hydrodynamic Separafor Combined Sewer Overflow. Hydro Research and Development Ltd. Conference on Practice and Performance, London, UK
  11. Hides, S. P. (1999) Grit Removal at Municipal Wastewater Treatment Plants, Proc. the Florida Water Resources Conf., Tallahassee FL
  12. Mecalf and Eddy (1991) Wastewater Engineering Treatment, Disposal and Reuse, McGraw-Hill, Inc.
  13. Smission, B. (1967) Design, Construction and Performance of Vortex Overflows. In Symposium on Sform Sewage Overflows, Institution of Civil Engineers (lCE), London, pp. 99-110