안와첨부 이물 육아종의 치험례

Clinical Experience of Foreign Body Granuloma in the Apex of Orbit

  • 백혜원 (가톨릭대학교 의과대학 성형외과학교실) ;
  • 최종우 (가톨릭대학교 의과대학 성형외과학교실) ;
  • 정현권 (가톨릭대학교 의과대학 성형외과학교실) ;
  • 이백권 (가톨릭대학교 의과대학 성형외과학교실) ;
  • 안상태 (가톨릭대학교 의과대학 성형외과학교실)
  • Paik, Hye Won (Department of Plastic Surgery Our Lady of Mercy Hospital, College of Medicine, The Catholic University of Korea) ;
  • Choi, Jong Woo (Department of Plastic Surgery Our Lady of Mercy Hospital, College of Medicine, The Catholic University of Korea) ;
  • Chong, Hyun Kwon (Department of Plastic Surgery Our Lady of Mercy Hospital, College of Medicine, The Catholic University of Korea) ;
  • Lee, Paik Kwon (Department of Plastic Surgery Our Lady of Mercy Hospital, College of Medicine, The Catholic University of Korea) ;
  • Ahn, Sang Tae (Department of Plastic Surgery Our Lady of Mercy Hospital, College of Medicine, The Catholic University of Korea)
  • 투고 : 2004.05.23
  • 발행 : 2005.01.10

초록

It is often difficult to identify and localize intraorbital foreign bodies despite of modern high-resolution imaging investigation. Especially, posteriorly located foreign bodies have increased risks of morbidity that surgical approach is often complicated. No matter how trivial it seems, retained foreign body, particularly organic in nature, may give rise to severe orbital and cerebral complications. High clinical suspicion, proper diagnostic studies, timely referral to a skilled orbital surgeon are mandatory. We report a case of intraorbital wooden foreign body that required two separate exploration for removal. Initial exploration failed to identify and locate the foreign body completely. After the operation, fistula formation and purulent discharge were developed and the imaging investigation results were equivocal, complicating the management. A second exploration yielded multiple intraorbital wooden foreign body in the apex of orbit. The patient fully recovered without complication. The evaluations and the details of management strategy are discussed.

키워드

참고문헌

  1. Fulcher TP, McNab AA, Sullivan TJ: Clinical features and management of intraorbital foreign bodies. Ophthalmology 109: 494, 2002 https://doi.org/10.1016/S0161-6420(01)00982-4
  2. Kim HK, Chung WS: Clinical experience of intraorbital foreign body. J Korean Ophthalmol Soc 38: 177, 1997
  3. Cartwright MJ, Kurumety UR, Frueh BR: Intraorbital wood foreign body. Ophthal Plast Reconst Surg 11: 44, 1995 https://doi.org/10.1097/00002341-199503000-00008
  4. Reshaf PS, Ossoinig KC, Nerad JA: Diagnosis and intraoperative localization of a deep orbital organic foreign body. Orbit 6: 3, 1987 https://doi.org/10.3109/01676838709036066
  5. Uchino A, Kato A, Takase Y, Kudo S: Intraotbital wooden and bamboo foreign bodies: CT. Neuroradiology 39: 213, 1997 https://doi.org/10.1007/s002340050396
  6. Macrae JA: Diagnosis and management of a wooden orbital foreign body: case report. Br J Ophthalmol 14: 176, 1977
  7. Green BF, Kraft SP, Carter KD, Buncic JR, Nerad JA, Amstrong D: Intraorbital wood. Ophthalmolgy 97: 608, 1990