Evaluation of Design Formulae for T-joints on the Branch Plate and Hollow Steel Sections welded connections

지관 플레이트가 주관에 용접된 각형강관 접합부의 설계내력 평가에 관한 연구

  • Received : 2005.07.05
  • Accepted : 2005.09.29
  • Published : 2005.10.27

Abstract

This paper proposes a design formulae that evaluates the design strength of T-joints made of cold-formed square hollow steel sections with longitudinal branch plate. The T-joints had a configuration that a branch member used to longitudinal plate to the main chord in the plane. This study focused on the branch plate T-joints governed by the main chord flange failure mode among the experimental results. Based on the test results of the longitudinal branch plate T-joint in the square hollow sections, the ultimate strength on the T-joints was defined as 1.5 times the load at 1% B the strength of joints that governed the serviceability in control for $16.7{\leq}2\gamma(B/T){\leq}31.3$ and $0.20{\leq}{\beta}(b1/B){\leq}0.75$. Existing yield line models for normal T-joints were investigated to be the main chord flange failure for the branch plate T-joint, and this proposal design formula was based on the theory of the yield line model. Finally, the value of the finite element method compared with the value of the test and theory for the T-joints verified the validity of the design formulae.

본 논문의 목적은 지관이 종방향 플레이트인 냉간성형 각형강관 T형 접합부의 최대내력 평가를 통하여 설계내력식을 제안하는 것이다. 이러한 T형 접합부의 형상은 지관에 플레이트를 이용하여 각형강관 주관면에 길이방향으로 용접하는 형상이고, 지관 플레이트를 갖는 각형강관 T형 접합부 실험결과 중에서 주관 플랜지 휨파괴가 지배하는 접합부만을 대상으로 하였다. $16.7{\leq}2{\gamma}(B/T){\leq}31.3$ 이고 $0.20{\leq}{\beta}(b1/B){\leq}0.75$ 범위의 지관 플레이트를 갖는 T형 접합부에 대하여, 접합부의 내력은 강도보다는 사용성이 지배하는 나타나 최대내력을 주관폭(B)의 1.5 P1%B로 정의하였다. 기본 접합부 형상에 대해 제안된 항복선모델을 참조하여 지관 플레이트를 갖는 접합부 형상에 대한 새로운 수정된 항복선 모델을 제안하였다. 최종적으로 유한요소해석과 항복선 해석에 근거한 제안 설계내력식과 실험결과를 비교하여 타당성을 검증하였다.

Keywords

References

  1. 배규웅, 박금성, 강창훈, 문태섭(2002a) 냉간성형 각형강관 모살용접 T형 접합부의 최대내력(I)-주관 플랜지 파괴 모드, 한국강구조학회논문집, 한국강구조학회, 14권 2호, pp.311-318
  2. 배규웅, 박금성, 강창훈, 문태섭(2002b) 냉간성형 각형강관 모살용접 T형 접합부의 최대내력(II)-주관 웨브 파괴모 드, 한국강구조학회논문집, 한국강구조학회, 14권 3호, pp. 403-411
  3. 정상민, 박금성, 배규웅, 문태섭(2005) 종방향 지관 플레이트 각형강관 T형 접합부의 구조적 거동, 대한건축학회논문집 구조계, 대한건축학회, 20권 12호, pp. 53-60
  4. J.J. Cao, J.A. Packer, N. Kosteski(1998) Design guidelines for longitudinal plate to HSS connections, Journal of structural engineering, pp. 784-791
  5. CIDECT(1986) The strength and behavior of statically loaded welded connections in structural hollow sections, CIDECT Monograph No. 6, Corby, England
  6. J.L. Dawe, S.J. Guravich(1993) Branch plate to reinforced HSS connections in tension and compression, Can.J.Civ.Eng.20, pp. 631-641
  7. International Institute of Welding(1989) Design recommendation for hollow section jointspredominantly statically loaded, IIW Doc. V-701-89, 2nd edition
  8. Kato, B., Nishiyama I.(1980) T-joints made of rectangular tubes. Proceeding of the 5th International Conference on Cold-Formed Steel Structures, St. Louis (MI, USA)
  9. Lu, L.H., de Winkel, G.D., Yu, Y., Wardenier, J. (1994) Deformation limit for the ultimate strength of hollow section joints, Tubular Structure Ⅵ, Rotterdam; Balkema, pp. 341-7
  10. Lu, L.H.(1997) The static strength of I-beam to rectangular hollow section connection, phD thesis, Delft University of Technology, The Netherlands
  11. N. Kosteski, J.A. Packer, R.S. Puthli (2003) A finite element method based yield load determination procedure for hollow structural, Journal of Constructional Steel Research, 59 453-471 https://doi.org/10.1016/S0143-974X(02)00066-4
  12. N. Kosteski, J.A. Packer(2003) Longitudinal Plate and Through Plate-to-Hollow Structural Section Welded Connections, Journal of Structural Engineering, ASCE, pp. 478-486
  13. Packer, J.A., Wardenier, J., Kurobane, Y., Dutta, D (1992) Design guide for rectangular hollow section (RHS) joints under predominantly static loading., Köln, Verlag TUV Rheinland. Swanson Analysis Systems. ANSYS release 9.0
  14. Yura J.A., Zettlemoyer N., Edwards I.F(1980) Ultimate capacity equation for tubular joints, OTC Proceedings
  15. Zhao, X.L.(2000) Deformation limit and ultimate strength of welded T-joints in cold-formed RHS sections, Journal of constructional steel research, 53 ; pp.149-165
  16. Journal of constructional steel research v.53 Deformation limit and ultimate strength of welded T-joints in cold-formed RHS sections Zhao, X.L.