Electrosorption of U(VI) by Surface-Modified Activated Carbon Fiber

표면처리 활성탄소섬유에 의한 U(VI)의 전기흡착

  • Lee, Yu Ri (Department of Chemical Engineering, Chungnam National University) ;
  • Jung, Chong Hun (Korea Atomic Energy Research Institute) ;
  • Ryu, Seung Kon (Department of Chemical Engineering, Chungnam National University) ;
  • Oh, Won Zin (Korea Atomic Energy Research Institute)
  • 이유리 (충남대학교 화학공학과) ;
  • 정종헌 (한국원자력연구소 제염해체기술연구개발부) ;
  • 유승곤 (충남대학교 화학공학과) ;
  • 오원진 (한국원자력연구소 제염해체기술연구개발부)
  • Received : 2004.09.09
  • Accepted : 2004.10.10
  • Published : 2005.02.28

Abstract

The electrosorption of U(VI) from waste water was carried out by using activated carbon fiber(ACF) felt electrode in a continuous electrosorption cell. In order to enhance the electrosorption capacity at lower potential, ACF felt was chemically modified in acidic, basic and neutral solution. Pore structure and functional groups of chemically modified ACF were examined, and the effect of treatment conditions was studied for the adsorption of U(VI). Specific surface area of all ACFs decreases by this treatment. The amount of acidic functional groups decreases with basic and neutral salt treatment, while the amount increases a lot with acidic treatment. The electrosorption capacity of U(VI) decreases on using the acid treated electrode due to the shielding effect of acidic functional groups. Base treated electrode enhances the capacity due to the reduction of acidic functional groups. The electrosorption amount of U(VI) on the base treated electrode at -0.3 V corresponds to that of ACF electrode at -0.9 V. Such a good adsorption capacity was not only due to the reduction of shielding effect but also the increase of $OH^-$ in the electric double layer on ACF surface by the application of negative potential.

연속적 전기흡착 셀에서 활성탄소섬유 부직포 전극을 사용하여 U(VI) 함유 폐액을 처리하였다. 더 낮은 전위에서 U(VI)의 전기흡착 효율을 높이기 위하여 ACFs를 화학약품으로 표면처리하고 그의 세공구조 및 관능기의 변화를 조사하였으며 처리조건이 U(VI)의 흡착에 미치는 영향을 고찰하였다. 표면처리한 모든 ACFs의 비표면적은 감소하였다. 중성염 및 염기성 용액으로 처리한 ACFs의 산성관능기는 감소했지만 산성 용액으로 처리한 ACFs의 산성관능기는 증가하였다. 산성관능기는 U(VI)의 흡착을 차단하여 산성용액 처리 ACFs 전극은 처리하지 않은 ACFs 전극에 비하여 U(VI)의 흡착용량이 감소했다. 중성염과 염기성 용액으로 처리한 ACFs 전극은 흡착용량이 크게 증가하여 -0.3 V의 낮은 전위에서도 처리하지 않은 ACFs 전극의 -0.9 V에 상응하는 결과를 얻었다. 이러한 결과는 ACFs 표면의 산성관능기 감소에 의한 이온의 차단효과(Shielding effect)가 줄어들 뿐만 아니라 음전위 가용에 의한 전기이중층 내에서의 $OH^-$의 증가로 U(VI) 흡착이 효율적으로 진행되었기 때문이다.

Keywords

Acknowledgement

Supported by : 한국과학기술기획평가원

References

  1. Carley-Macauy, K. W. and Gutman, R. G., Radioactive Waste: Advanced management methods for Medium Active Liquid Waste, Harwood Academic Pub(1981)
  2. Woodard, F. E., McMackins, D. E. and Jansson, R. E. W., 'Electrosorption of Organic on Three Dimensional Carbon Fiber Electrode,' J. Electroanal. Chem., 214, 303-330(1986) https://doi.org/10.1016/0022-0728(86)80105-X
  3. Oren, Y. and Soffer, A., 'Water Desalting by Means Of Electrochemical Parametric Pumping,' J. Applied Electrochemistry, 13, 473-484(1983) https://doi.org/10.1007/BF00617522
  4. Jayson, G. G., Sangster, J. A., Thompson, G. and Wilkinson, M. C., 'Adsorption an Electrosorption of Mercury(II) Acetate onto Activated Charcoal Cloth from Aqueous Solution,' Carbon, 25, 523-531(1987) https://doi.org/10.1016/0008-6223(87)90193-X
  5. Oren, Y. and Soffer, A., 'Graphite Felts as an Efficient Porous Electrode for Impurity Removal and Recovery of Metals,' Electrochemica Acta., 28, 1649-1654(1983) https://doi.org/10.1016/0013-4686(83)85230-X
  6. Ryu, S. K., 'Porosity of Activated Carbon Fiber,' High Temperature-High Presure, 22, 345-354(1990)
  7. Marsh, H., Heintz, E. A. and Rodriguez-Reinoso, F., 'Introduction to Carbon Technologies,' University of Alicante, 42-45(1997)
  8. Park, S. J., Park, B. J. and Ryu, S. K., 'Electrochemical Treatment on Activated Carbon Fibers for Increasing the Amount and Rate of Cr(VI) Adsorption,' Carbon, 37, 1223-1226(1999) https://doi.org/10.1016/S0008-6223(98)00318-2
  9. Hong, L. I., Moshonov, A. and Muzzy, J. D., 'Electrochemical Polymerization of Xylene Derivatives on Carbon Fiber,' Polym. Compos., 12, 191-201(1991) https://doi.org/10.1002/pc.750120309
  10. Drzal, L. T. and Madhukar, M., 'Fibre-Matrix Adhesion and its Relationship to Composite Mechanical Properties,' J. Mater. Sci., 28, 569(1993) https://doi.org/10.1007/BF01151234
  11. Brunauer, S., Emmett, P. H. and Tellet, E., 'Adsorption of Gases in Multimolecular Layers,' J. Am. Chem. Soc., 60, 309(1938) https://doi.org/10.1021/ja01269a023
  12. Boehm, H. P., 'Chemisty of Heteroatoms on the Surface of Carbon(Plenary Lecure)', Carbon, 7, 715(1969)
  13. Park, S. J., Interfacial forces and field: theory and application, 1st ed, J. P. Hsu, Marcel Dekker, New York(1999)
  14. Shim, J. W., Park, S. J. and Ryu, S. K., 'Effect of Modification with $HNO_3$ and NaOH on Metal Adsorption by Pitch-Based Activated Carbon Fibers,' Carbon, 39, 1635-1642(2001) https://doi.org/10.1016/S0008-6223(00)00290-6
  15. Jr. Pittman, C. U., He, G. R., Wu, B. and Garner, S. D., 'Chemical Modification of Carbon Fiber Surfaces by Nitric Acid Oxidation Followed by Reaction with Tetraethylenepentamine', Carbon, 35, 317-331(1997) https://doi.org/10.1016/S0008-6223(97)89608-X
  16. Kim, H. S., Ryu, S. K., Jung, C. H. and Park, K. K., 'Electrosorption of Cobalts Ions by Chemically Treated ACF Discs,' HWAHAK KONGHAK, 41(6), 744-748(2003)
  17. Jung, C. H., 'A Study on the Preparation of Activated Carbon Fibers and Their Radioactive Co(II) Adsorption Characteristics,' Ph.D. Dissertation, ChungnamNational Univ., Deajeon, Korea (1994)
  18. Park, S. J., Kim, Y. M. and Shin, J. S., 'Studies on Anodic Oxidation Treatment of Surface and Heavy Metal Adsorption Properties of Activated Carbon Fibers,' J. Korean Ind. Eng. Chem., 14, 41-47(2003)
  19. Takamura, T., Awano, H., Ura, T. and Ikezawa, Y., 'Effective Surface Treatment to Improve the Li Doping and Undoping Characteristics of Carbon Fiber as a Li Secondary Battery Anode,' 36th Battery Symposium, Japan, 92-92(1995)