Abstract
Experimental study was conducted to increase the oxygen transfer efficiency of air diffusers in clean water. By measuring the bubble size from the bubbly two-phase flow visualization with several air diffusers, the size of air bubbles near the top surface of aeration tank seems to be independent on the diffuser types. Considering design parameters for the better break-up of larger bubbles around the air diffusers, advanced conceptual air diffusers using nozzle-type throat showing the higher oxygen transfer efficiencies were made.