Ballast Design for HID Lamps with Automatic Identification

HID 램프를 자동 인식하는 안정기 설계

  • Published : 2005.10.01

Abstract

An electronic ballast with automatic identification between HPS and MH lamps is proposed in this paper. The behavior of the lamp impedance is studied at both cold-starting and warm-starting. Lamp identification is carried out by taking into account the rate of impedance changing at constant current driving mode just after ignition. The ballast consists of 8-bit microcontroller and LCC resonant inverter.

Keywords

References

  1. Marcio A. Co and C. Z. Rezende, 'Microcontrolled electronic gear for HID lamps-comparisons with electromagnetic ballast', IEEE IES Conf. 2002, pp.468-472 https://doi.org/10.1109/IECON.2002.1187553
  2. Douglas Dorr and Arshad Mansoor, 'Applying HID high-pressure sodium lamps in a variable- voltage environrnent', IEEE IAS Conf. 1995, pp.2059-2065 https://doi.org/10.1109/IAS.1995.530564
  3. L. Laskai, P. Enjeti and I. J. .Pitel, 'White-noise modulation of high frequency high intensity discharge lamp ballasts', IAS'94 meeting Reports, pp.1953-1961, 1994
  4. 이치환, '진폭변조에 의한 메탈핼라이드 램프의 음향공명 감소', 조명전기설비학회 논문지, vol. 14, no. 5, p.43-49, Sep. 2000
  5. 이치환, '고압 나트륨등용 전자식 안정기의 설계', 대한전자공학회 전력전자 학술발표회 논문집, vol. 20, no. 1, pp.93-102, 1998
  6. 이치환, '400W 메탈 핼라이드 램프의 전자식 안정기 구현', 조명전기설비학회 학술대회, pp.111-115, 2000
  7. Shmuel Ben-Yaakov and Michael Gulko, 'Design and performance of an electronic ballast for high-pressure sodium(HPS) lamps', IEEE Trans. on IE vol. 44, no. 4, pp.486-491, Aug. 1997 https://doi.org/10.1109/41.605623
  8. J. Correa, M. Ponce, A. Lopez and J. Arau, 'A comparioson of LCC and LC filters for its application in electronic ballast for metal-halide lamps', IEEE PESC 2001, pp.114-1l9 https://doi.org/10.1109/PESC.2001.954004