Combustion Characteristics of RDF in a 30kg/hr Scale Pyrolysis Melting Incinerator

30kg/hr급 열분해 용융소각로용 연소실에서 RDF의 연소 특성

  • 전병일 (연세대학교 기계공학부) ;
  • 박상욱 (연세대학교 기계공학부) ;
  • 신동훈 (국민대학교 기계.자동차 공학부) ;
  • 류태우 (한국생산기술연구원) ;
  • 황정호 (연세대학교 기계공학부)
  • Published : 2005.03.31

Abstract

In this study, we investigated characteristics of a gas flow and a combustion property during the combustion of a RDF in a pyrolysis melting incinerator with disposal rate of 30 kg/hr. The RDF was pyrolyzed through the pyrolysis chamber at $600^{\circ}C$ of the chamber surface without oxygen condition. The pyrolysis gas was injected in the combustion chamber. It was burned by means of the staged combustion that was injecting secondary and tertiary air in the combustor. We measured the temperatures and the gas components in the combustion chamber while maintaining the air-fuel ratio of 1.3. Finally, we confirm that additional air injection, secondary and tertiary air ratio, was the most important factor to reduce NOx.

Keywords