Abstract

In this paper, seismic qualification analysis for the Plant control Panel is carried out to confirm the structural integrity under the seismic conditions represented by required response spectra(RRS). The finite element method(FEM) is used for the analysis and a mode combination method is adopted to obtain a more reliable spectrum analysis results. In addition, the experimental analysis is performed to compare the reliability of the analytical results. The analysis results shows that the plant control panel system is designed to have the dynamic rigidity with no resonance frequency below 33 Hz. The analytically calculated maximum stress of the plant control panel system is $36\%$ of the field strength of material, thus it can be shown that the system has a stable structure for the seismic load.

Keywords

References

  1. IEEE Std., 1987, 'Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations', pp. 344-348
  2. 김종욱, 홍성욱,1999, '엄밀한 동적 요소를 이용한 프레임 구조물의 모델링 및 모드해석', 한국소음진동공학회논문집, 제 9 권, 제 5 호, pp. 966-974
  3. 우성현, 문상무, 김홍배, 이상설, 1999, '핵연료 봉지지 구조물의 모드해석 및 유한요소 모형 개선', 한국소음진동공학회 추계학술대회논문집, pp. 876-884
  4. US NRC Regulatory Guide 1.29, 1978, Seismic Design Classification
  5. R. W. Clough, J. Penzien, 1993, Dynamics of Structures, McGRAW-Hill
  6. 하동호, 고현무, 1999, '마찰 형 면진받침을 가진 지진격리교량의 지진응답해석', 한국소음진동공학회 춘계학술대회논문집, pp. 96-101
  7. AISC(American Institute of Steel Construction), 1989, Manual of Steel Construction Allowable Stress Design -ninth Edition
  8. IEEE Std., 1983, Qualifying Class 1E Equipment for Nuclear Power Generating Stations, PP. 323- 1983
  9. Kim. W. H ., Oh, D. H. and Joo, W. H., 2003, 'A Study on the Seismic Qualification of Gas Insulated Switchgear Using Analytical Method', 10th ICSV Proceeding