An estimating method for systolic blood pressure by using pulse transit time and physical characteristic parameters

맥파전달시간과 신체특징 파라미터를 이용한 수축기 혈압측정

  • Lee Sangmin (Division of Bionics and Bioinformatics, Chonbuk National University) ;
  • Park Eun Kyung (Dept. of Biomedical Engineering, Hanyang University) ;
  • Kim In Young (Dept. of Biomedical Engineering, Hanyang University) ;
  • Kim Sun I. (Dept. of Biomedical Engineering, Hanyang University)
  • Published : 2005.05.01

Abstract

In this paper, we proposed noninvasive and continous measurement of blood pressure using pulse transit time(PTT) and physical characteristic parameters and verified its clinical effectiveness. PTT can be obtained by electrocardiogram and phtoplethysmogram. There are many researches for estimating blood pressure using PTT which can be used for individual. However, it is not enough for extracting general regression equation which can estimate blood pressure for unspecified people. In this study, we suggested the regression equatin using PTT and physical characteristic parameters related to blood pressure and did measure blood pressure of many people. we compared the performance between two methods. As the results, we knew that the regressin model using PTT combined with physical characteristic parameters can estimate blood pressure more acurately and is closer to American National Standards Institute of the Association of the Advancement of Medical Instrument(ANSI/AAMI).

본 논문에서 맥파전달시간과 신체 특징 파라미터들을 이용하여 비침습적이고 연속적으로 혈압을 측정할 수 있는 방법을 제시하고 임상실험을 통하여 검증하였다. 맥파전달시간은 심전도와 광전용적맥파로부터 구한다. 맥파전달시간만 이용하여 개개인의 혈압을 측정하는 방법이 연구되었지만 이 방법은 모든 사람에게 적용 가능한 범용 회귀식을 도출하기 부족한 면이 있다. 이 연구에서 혈압과 관련되는 신체 특징 파라미터들과 맥파전달시간을 이용하여 모든 사람에게 적용 가능한 범용 회귀식을 도출하여 여러 사람들의 혈압을 측정하였다. 맥파전달시간만 이용하여 만든 회귀방법과 맥파전달시간과 신체 특징 파라미터들을 같이 이용하여 만든 회귀방법을 서로 비교 하였다. 실험 결과, 맥파전달시간과 신체 특징 파라미터를 이용하는 회귀방법이 여러 사람들의 혈압을 더 정확히 측정할 수 있다는 것을 알 수 있었고, American National Standards Institute of the Association of the Advancement of Medical Instrument(ANSI/AAMI)에 더 근접함을 알 수 있었다.

Keywords

References

  1. J. G. Webster, 'MEDICAL INSTRUMENTATION : Application and design, third edition,' WILEY, New York, pp. 287-331, 1998
  2. D. A. Paulus, 'Noninvasive blood pressure measurement,' Medical Instrumentation, Vol.15(2), pp. 91-94, 1981
  3. J. M. R. Bruner, 'Automated indirect blood pressure measurement a point of view,' Medicla Instrumentation, Vol. 18(2), pp 143-145, 1984
  4. L. A. Geddes and M. H. Voelz, 'Pulse Transit Time as an Indicator of Arterial Blood Pressure,' Psychophysiology, Vol. 18, No 1, pp. 71-74, 1981 https://doi.org/10.1111/j.1469-8986.1981.tb01545.x
  5. K. W. Chan and Y. T. Zhang, 'NONINVASIVVE AND CUFFLESS MEASUREMENTS OF BLOOD PRESSURE FOR TELEMEDICINE', 2001 Proceedings of the 23rd Annual EMBS Conference, pp. 3592-3593, Istanbul, Turkey. 2001
  6. 최병철, '광전용적맥파를 이용한 맥파전달시간 시스템 구현 및 평가', 공학박사학위 논문, 부산대학교, 2004
  7. J. E. Naschitz, I. Rosner, N. Shaviv, I Khorshidi, S. Sundick, 'Assessment of cardiovascular reactivity by fractal and recurrence quantification analysis of heart rate and pulse transit time', J Hum Hypertens. Feb;17(2): 111-8, 2003 https://doi.org/10.1038/sj.jhh.1001517
  8. D. Pitson, A. Sandell, Van de Hoot, J. R. Stradling, 'Pulse transit time as a measure of respiratory effort in patients with obstructive sleep apnea,' Eur Respir J, 8:1669-1674, 1995 https://doi.org/10.1183/09031936.95.08101669
  9. 이희정, 정도운, '손가락에서의 맥파전달시간 특성과 체질량지수와의 관계,' 대한의용생체공학회 춘계학술대회 p21, 대구 컨벤션 센터, 한국, 2004
  10. James D. Lane, Lisa Greenstadt, David Shapiro, 'Pulse Trasit Time and Blood Pressure : An Intensive Analysis,' Psychophysiology, Vol. 20, No. 1, pp. 45-49, 1983 https://doi.org/10.1111/j.1469-8986.1983.tb00899.x
  11. 노형진, '한글 SPSS 10.0에 의한 조사방법 및 통계분석,' 형설출판사, p317-358 2001
  12. Claudia Langenberg and Rebecca Hardy, 'Influence of height, leg and trunk length on pulse pressure, systolic and diastolic blood pressure,' Journal of Hypertension, No21 : 527-543, 2003
  13. Steve Anderson and Germaine Cornelissen, 'Age effects upon the harmonic structure of human blood pressure in clinical health,' Proceeding, Second Annual IEEE Symposium on Computer-Based Medical Systems, Minneapolis, MN USA, 26-27, pp. 238-243, June 1989 https://doi.org/10.1109/CBMSYS.1989.47383