Abstract
Post-tensioned Precast concrete System(PPS) consists of U-shaped precast wide beams and concrete column. The continuity of beam-column joint is provided with floor concrete cast on the PC shell beam and post-tensioning. The purpose of this paper is to evaluate the response of PPS interior beam-column joint subjected to cyclic lateral loading. To this end, an experimental investigation was performed with three half-scale specimens of interior connection. The design parameters are the amount of beam reinforcement placed inside the joint core. The test results showed that cracks were distributed well without my significant degradation of strength and ductility. Also, it was found that the prestressing may affect to alter the torsional crack angle. And the specimens sufficiently resist up to limiting drift ratio of 0.035 in accordance with the provisional by ACl of acceptance criteria for concrete special moment frames.
PPS(post-tensioned precast concrete system)공법은 U자형 PC로 제작한 넓은 보와 PC 또는 현장 타설 콘크리트로 제작한 기둥으로 구성되며 PC 보와 기둥의 일체성 확보를 위하여 프리스트레스를 도입하였다. 본 연구는 PPS 공법 개발의 일부로 넓은 보의 기둥 폭 내부에 정착되어진 휨철근의 양에 따른 거동특성을 분석하고자 실험적 연구를 수행하였다. 실험체는 기둥 폭내, 외부에 위치한 휭 철근의 양을 달리한 정착비와 동일한 정착비내에서 철근과 긴장재의 양을 주요변수로 하여 대상건물의 내부접합부를 대상으로 1/2크기로 제작하였다. 그 결과 NEHRP 권고사항에서 규정한 한계변위각 0.035까지 내력저하 없이 충분한 내력을 보유하였으며, 보의 휨 파괴가 주요 파괴모드로 접합부에서 전단파괴는 일어나지 않았다. 그리고 넓은 보에 포스트텐션을 도입한 PPS 공법은 기둥 폭 내부의 정착비가 $35\%$인 경우 다소 높은 비틀림 응력을 나타내었으나, 기둥 폭 외부에 위치한 인장철근의 항복 이후 긴장재가 응력을 충분히 발휘함으로서 일체식 구조의 넓은 보-기둥 접합부와 달리 비탄성 이력거동을 통하여 에너지를 효과적으로 소산하였다. 또한 ACI의 proposed provisional standard의 PC 접합부 구조성능 평가지침에 의해 분석한 결과, 모든 실험체에서 허용기준을 모두 만족하고 있으며, 강도의 큰 저하 없이 연성적인 거동을 하고 있음을 알 수 있었다.