References
- W. Weppner, 'Solid state electrochemical gas sensors', Proc. 2nd Meet. Chem. Sensor, Bordeaux, France, 7-10, pp. 59-68, 1986
- M. Gauthier and A. Chamberland, 'Solid-state detectors for the potentiometric determination of gaseous oxides', J. Electrochem. Soc., vol. 124, pp. 1579-1583, 1977 https://doi.org/10.1149/1.2133113
-
E. Steudel, P. Birke, and W. Weppner, 'Miniaturized solid state electrochemical
$CO_2$ sensors', Electrochemica Acta, vol. 42, pp. 3147-3153, 1997 https://doi.org/10.1016/S0013-4686(97)00168-0 -
F. Qiua,* L. Sun, X. Li, M. Hirata, H. Suo, and B. Xu, 'Static characteristic of plannar-type
$CO_2$ sensor based on NASICON and with an inner-heater', Sensors and Actuators B, vol. 45, pp. 233-238, 1997 https://doi.org/10.1016/S0925-4005(97)00311-0 -
F. salam, S. Bredikhin, P. Birke, and W Weppner, 'Effect of the thickness of the gas-sensitive layer on the response of solid state electrochemical
$CO_2$ sensors', Solid State lonics, vol. 100, pp. 319-325, 1998 https://doi.org/10.1016/S0167-2738(97)00111-2 - K. Kaneyasu, K. Otsuka, Y. Setoguchi, S. Sonoda, T. Bakahara, I. Aso, and N. Nakagaiehi, 'A carbon dioxide gas sensor based on solid eletrolyte for air quality control', Sensors and Actuators B, vol. 66, pp. 56-58, 2000 https://doi.org/10.1016/S0925-4005(99)00411-6
-
Y. Shimizu and N. Yamashita, 'Solid electrolyte
$CO_2$ sensor using NASICON and perovskite-type oxide electrode, Sensors and Actuators B, vol. 64, pp. 102-106, 2000 https://doi.org/10.1016/S0925-4005(99)00491-8 -
H. Nafe and F. Aldinger, '
$CO_2$ sensor based on a solid state oxygen concentration cell', Sensors and Actuators B, vol. 69, pp. 46-50, 2000 https://doi.org/10.1016/S0925-4005(00)00333-6 -
T. Kida, H. Kawate, K. Shimanoe, N. Miura, and N. Yamazoe, 'Interfacial structure ofNASI CON-based sensor attached with
$Li_2$ $CO_3$ $CaCO_2$ auxiliary phase for detection of$CO_2$ ' , Solid State lonics, vol. 136-137, pp. 647-653, 2000 https://doi.org/10.1016/S0167-2738(00)00323-4 -
T. Kida, K. Shimanoe, N. Miura, and N. Yamazoe, 'Stability of NASICON-based
$CO_2$ sensor under humid conditions at low temperature', Sensors and Actuators B, vol. 75, pp. 179-187,2001 https://doi.org/10.1016/S0925-4005(01)00549-4 - S. Zhang, B. Quan, Z. Zhao, B. Zhao, Y. He, and W. Chen, 'Preparation and characterization of NASICON with a new sol-gel process', Materials Letter, vol. 58, pp. 226-229, 2003
- E. Traversa, H. Aono, Y. Sadaoka, and L. Montanare, 'Electrical properties of sol-gel precessed NASICON having new compositions', Sensors and Actuators B, vol. 65, pp. 204-208, 2000 https://doi.org/10.1016/S0925-4005(99)00293-2
-
F. Qiua, Q. Zhu, X. Yang, Y. Quan, and B. Xu, 'Preparation of planar
$CO_2$ sensor based on solidelectrolyte NASICON synthesized by sol-gel process', Materials Chemistry Physics, vol. 83, pp. 193-198, 2004 https://doi.org/10.1016/S0254-0584(03)00157-3 -
M.G. Seo, K.D. Song, J.S. Kwak, and D.D. Lee, '
$CO_2$ gas sensing characteristics of lithium ionic solid electrolyte prepared by sol-gel method' J. Kor. Sens. Soc., vol. 4, pp. 22-29, 1995 -
W.F. Chu, D. Fischer, H. Erdmann, M. Ilgenstein, H. Koppen, and V. Leonhard, 'Thin and thick film electrochemical
$CO_2$ sensors', Solid State lonics, vol. 53-56, pp. 80-84, 1992 - Y.I. Bang, K.O. Song, B.S. Joo, J.S. Huh, S.D. Choi, and D.D. Lee, 'Thin film micro carbon dioxide sensor using MEMs process', Sensors and Actuators B, vol. 102, pp. 20-26, 2004 https://doi.org/10.1016/j.snb.2003.11.039
-
S.D. Choi, 'Thermodynamic analysis of solid electrolyte
$CO_2$ sensor in continuous and discontinuous flow system', J. Kor. Sens. Soc., vol. 7, pp. 319-326, 1998 -
P. Pasierb, S. Komomicki, S. Kozinski, R. Gajerski, and M. Rekas, 'Long-term stability of potentiometric
$CO_2$ sensors based on Nasicon as a solid electrolyte', Sensors and Actuators B, vol. 101, pp. 4756, 2004 https://doi.org/10.1016/j.snb.2004.02.021 -
C. Lee, S.A. Akbar, and C.O. Park, 'Potentiometric
$CO_2$ gas sensor with lithium phosphorous oxynitride electrolyte', Sensors and Actuators B, vol. 80, pp. 234-242, 2001 https://doi.org/10.1016/S0925-4005(01)00902-9 -
C.O. Park, C. Lee, S.A Akbar, and J. Hwangc, 'The origin of oxygen dependence in a potentiometric
$CO_2$ sensor with Li-ion conducting electrolyte', Sensors and Actuators B, vol. 88, pp. 53-59, 2003 https://doi.org/10.1016/S0925-4005(02)00308-8