PE 선피복 파형강관의 부식 및 마모 특성

Corrosion and Abrasion Characteristics of PE Sheet Laminated Corrugated Steel Pipe

  • 김석구 (한국건설기술연구원 건설환경연구부) ;
  • 정장식 (환경관리공단 기술진흥처) ;
  • 곽필재 (한국건설기술연구원 건설환경연구부) ;
  • 최준향 (한국건설기술연구원 건설환경연구부) ;
  • 이현동 (한국건설기술연구원 건설환경연구부) ;
  • 이태윤 (한국건설기술연구원 건설환경연구부)
  • Kim, Seog-ku (Construction Environment Research Department, Korea Institute of Construction Technology) ;
  • Jeong, Jang-sik (Engineering Promotion Department, Environmental Management Corporation) ;
  • Kwak, Phill-jae (Construction Environment Research Department, Korea Institute of Construction Technology) ;
  • Choi, Jun-hyang (Construction Environment Research Department, Korea Institute of Construction Technology) ;
  • Lee, Hyun-dong (Construction Environment Research Department, Korea Institute of Construction Technology) ;
  • Lee, Tae-yoon (Construction Environment Research Department, Korea Institute of Construction Technology)
  • 발행 : 2004.03.30

초록

Feasibility of using PE sheet laminated CSP(Corrugated steel pipe) to sewers were tested via corrosion and abrasion tests for PE sheet laminated CSP; 1) corrosion test for PE film and PE coated plate, 2) corrosion test for joint of PE sheet laminated CSP, 3) corrosion test for outside of PE sheet laminated CSP, and 4) abrasion test for inside of PE sheet laminated CSP. The results for the corrosion and abrasion tests are as follows. 1. Results for corrosion tests on PE films and zinc coated steel plates that were coated with PE films show that the surfaces of both PE were not changed compared to those of original PE samples. Furthermore, PE films maintained strong adhesion on the steel plates even though they were exposed to sewage and seawater provided cutting planes of the steel plates were treated with molding. But, results for corrosion tests on the spots that were previously cut off by a knife and a cutting planes of the steel plates were treated without molding show that steel plates have been corroded if they were exposed to sewage and seawater. 2. Results for corrosion tests on joints of PE sheet laminated corrugated steel using sewage show that gathering rust was observed at cutting plane of PE sheet laminated corrugated steel after 180 days, but PE film was not flaked off. However, PE film at cutting plane was flaked off when PE sheet laminated corrugated steel was exposed to seawater. Furthermore, flaking process was severely progressed at lockseam points of which the surfaces were not smooth. 3. Results for laying PE sheet laminated corrugated steel under the ground show that the surface of untouched PE film was almost identical to that of original PE film. However, the spots that were previously cut off by a knife and a cutting plane of PE sheet laminated corrugated steel have flaked off. 4. As a result of abrasion tests conducted with PE sheet laminated corrugated steel and sand, brilliance and thickness of PE was not greatly changed under the severe abrasion conditions. Therefore, the durability of PE sheet laminated corrugated steel for abrasion was determined to be good.

키워드

참고문헌

  1. NCSPA, Evaluation methodology for corrugates steel pipe coating/invert treatments (1996)
  2. NCSPA, CSP Durability Guide (2000)
  3. 포항산업과학연구원, 오수관용 파형강관 내구성 향상을 위한 피복 방안 (1998)
  4. 한국건설기술연구원, PE 선피복 파형강관의 하수관거 적용성 연구 (2003)
  5. ANSI, A21.5, American National Standards Institute (1972)
  6. 한국건설기술연구원, 상수도관로의 부식 및 노후도 예측모델 개발 (2002)