A Study on the Crevice Corrosion for Ferritic Stainless Steel

페라이트 스테인리스강의 틈부식에 대한 연구

  • Baik Shin-Young (Division of Engineering System, Mokpo National Maritime University)
  • 백신영 (목포해양대학교 기관시스템공학부)
  • Published : 2004.06.01

Abstract

In recently days, the breed fish farm is increased in the beach side for farming fish. In such a farm, the heater is requested for preventing freezing in cold season. The heating material are requested high corrosion resistance and strength for endurance high corrosive salt and pressure. In case of low corrosion resistance and/or strength, the heating element shall be broke down and eventually make spillage or leaking contaminated salt. In the most cases, crevice corrosion is localized form of corrosion usually associated with a stagnant solution on the micro-environmental level. In this study, the crevice corrosion of Ferritic type 430 stainless steel is investigated. The size of specimen is $15{\times}20{\times}3mmt$. Test solution is 1N H2SO4 + 0.05N NaCl. The artificial crevice gap size is $0.24{\times}3{\times}15mmL$. Crevice corrosion is measured under applied voltage 300mV(SCE) to the external surface. the result of this study showed that 1) the induced time for initiation of crevice is 750seconds, 2) potential is dropped in the crevice from the top of gap opening from -320 to -399mV. The result confirmed that the potential drop(IR mechanism) in the crevice is one of mechanism for crevice corrosion.

최근 양어 양식장은 증가하고 있으며 이러한 곳에 사용할 가열장치는 경울 수온 조절을 위해 사용된다. 해수 가열장치는 부식성이 높고 압력이 높은 곳에 사용하기 위하여 고강도와 내식성이 요구된다. 만약 저강도와 저내식성을 갖게 되면 결국 누설 또는 파손되어 해수오염을 일으킬 수 있다. 대부분의 부식은 정체된 액과 틈이 형성된 부위에서 부식의 발생이 일어난다. 이 연구에서는 430 스테인레스재를 크기 $15{\times}20{\times}3mmt$에 대하여 1N H2SO4 + 0.05N NaCl용액을 사용하여 틈부식을 시험하였다. 틈의 크기는 $0.24{\times}3{\times}15mmL$로 하였으며 외부에 300mV전위를 인가하였다. 실험 결과 틈 부식 유기 시간은 750초로 나타나고, 틈 전위 강화는 -320에서 -399mV로 나타나 부식의 주 원인이 전위강화 기구에 의해 발생하였다.

Keywords