참고문헌
- Chaiseri, P. (1990), "Characteristics, modelling and application of the tuned liquid damper", Ph.D. Thesis, The University of Tokyo, Japan.
- Den Hartog, J.P. (1956), Mechanical Vibrations, 4th Ed., McGraw-Hill Book Company: New York, NY, USA.
- Fuji, K., Tamura, Y., Sato, T. and Wakahara, T. (1990), "Wind-induced vibration of tower and practical applications of tuned sloshing damper", J. Wind Eng. Ind. Aerody., 33, 263-272. https://doi.org/10.1016/0167-6105(90)90042-B
- Graham, E.W. and Rodriguez, A.M. (1952), "The characteristics of fuel motion which affect airplane dynamics", J. Appl. Mech., 19(3), 381-388.
- Noji, T., Yoshida, H., Tatsumi, E., Kosaka, H. and Hagiuda, H. (1988), "Study on vibration control damper utilizing sloshing of water", J. Wind Eng. Ind. Aerody., 37, 557-566.
- Tait, M.J., Isyumov, N. and El Damatty, A.A. (2004a), "Testing of tuned liquid damper with screens and development of equivalent TMD model", Wind Struct., An Int. J., 7(4), 215-234. https://doi.org/10.12989/was.2004.7.4.215
- Vickery, B.J. and Davenport, A.G. (1970), "An investigation of the behaviour in wind of the proposed CenterPoint tower, in Sydney, Australia", Research Report BLWT-1-70, The Boundary Layer Wind Tunnel Laboratory, The University of Western Ontario, London, Canada.
- Wakahara, T., Ohyama, T. and Fujii, K. (1992), "Suppression of wind-induced vibration of a tall building using tuned liquid damper", J. Wind Eng. Ind. Aerody., 41-44, 1895-1906.
- Warburton, G.B. (1982), "Optimum absorber parameters for various combinations of response and excitation parameters", Earthq. Eng. Struc. Dyn., 10, 381-401. https://doi.org/10.1002/eqe.4290100304
피인용 문헌
- Numerical studies on the application of tuned liquid dampers with screens to control seismic response of structures vol.20, pp.2, 2011, https://doi.org/10.1002/tal.515
- Application of tuned liquid dampers in controlling the torsional vibration of high rise buildings vol.21, pp.5, 2015, https://doi.org/10.12989/was.2015.21.5.537
- Analytical and experimental study on natural sloshing frequencies in annular cylindrical tank with a bottom gap vol.57, pp.5, 2016, https://doi.org/10.12989/sem.2016.57.5.877
- Testing of tuned liquid damper with screens and development of equivalent TMD model vol.7, pp.4, 2004, https://doi.org/10.12989/was.2004.7.4.215
- Performance of Tuned Liquid Dampers vol.134, pp.5, 2008, https://doi.org/10.1061/(ASCE)0733-9399(2008)134:5(417)
- Modelling and preliminary design of a structure-TLD system vol.30, pp.10, 2008, https://doi.org/10.1016/j.engstruct.2008.02.017
- Effectiveness of a 2D TLD and Its Numerical Modeling vol.133, pp.2, 2007, https://doi.org/10.1061/(ASCE)0733-9445(2007)133:2(251)
- Reduced Equivalent Static Wind Loads for Tall Buildings with Tuned Liquid Dampers vol.226-228, pp.1662-7482, 2012, https://doi.org/10.4028/www.scientific.net/AMM.226-228.1218
- Development and Validation of Finite Element Structure-Tuned Liquid Damper System Models vol.137, pp.11, 2015, https://doi.org/10.1115/1.4030866
- A variably baffled tuned liquid damper to reduce seismic response of a five-storey building vol.171, pp.4, 2018, https://doi.org/10.1680/jstbu.16.00034