Evaluation and Application of Pullout Strength of Single Anchor in Plain Concrete According to Edge Distance

연단거리에 따른 무근콘크리트 단일앵커의콘파괴 인발 내력에 관한 적용성 평가

  • 김영호 (비비엠코리아(주) 기술연구소) ;
  • 유성근 (비비엠코리아(주) 기술연구소)
  • Received : 2003.11.17
  • Published : 2004.01.31

Abstract

This paper presents the evaluation of pullout strengths of expansion anchors and wedge anchors that can cause a failure of the concrete on the basis of the design for anchorage. Tests are conducted for heavy-duty anchors and wedge anchors domestically manufactured and to be installed in plain concrete member. The mainly testing parameters reflected the effects of edge distance. Design of post-installed steel anchors is presented by the Concrete Capacity Design(CCD) in European Organization for Technical Approval. This approach is compared to the well-known provisions, ACI 349-90 specification. The use of both methods to predict the concrete failure load of expansion anchor in uncracked concrete under monotonic loading for important applications is compared. In this study, the concrete tension capacity of fastenings with Heavy-duty Anchors and Wedge Anchors in plain concrete predicted by ACI 349-90 and the Concrete Capacity Design method has been compared with the results of tests.

본 연구의 대상은 익스팬션 앵커에 해당하는 국내산 중량물 앵커(heavy duty anchor)와 웨지 앵커(wedge anchor)에 대해서 앵커설계의 기초가 되는 콘파괴를 중심으로 무근콘크리트에서의 인발실험으로 국한된다. 각각의 앵커에 대해 ACI 349-90 설계기준과 EOTA (European Organization for Technical Approval) 기준의 근거인 CCD 설계방법에 의해서 연단거리를 변수로 한 앵커의 콘파괴강도 예측값과 실험값을 비교 평가하고자 하며, 이 연구를 근간으로 하여 국내산 앵커를 구조설계에 적용시 기초자료 제공을 목적으로 한다.

Keywords