A Study on the Characteristics of Pyrolysis of Methyl Ethyl Ketone Peroxide with Addition of Sulfuric Acid

황산의 첨가에 따른 Methyl Ethyl Ketone Peroxide의 열분해 특성에 관한 연구

  • 정두균 (한국소방안전협회) ;
  • 최재욱 (부경대학교 안전공학과) ;
  • 이인식 (부경대학교 안전공학과 대학원)
  • Published : 2004.12.01

Abstract

An experiment to examine the characteristics of pyrolysis of Methyl Ethyl Ketone Peroxide was conducted in an air-present environment, using TG-DTA. Decomposition starting temperature was decreased as the increase of 98% concentrated H₂SO₄ to the MEKPO and the maximum decomposition temperature of MEKPO was 116.8℃. The activated energy calculated from differential method of pure MEKPO, MEKPO with 1 wt%, 3wt%, and 5wt% of H₂SO₄ were 0.576㎉/mo1, 0.355㎉/㏖, 0.284㎉/㏖ and 0.258㎉/㏖ respectively.

Methyl Ethyl Ketone Peroxide의 열분해 특성을 파악하기 위하여 TG-DIA의 실험장치를 사용하여 공기 분위기 중에서 실험을 하였다. 그 결과 MEKPO에 98% H₂SO₄의 첨가량이 증가할수록 분해개시온도는 낮아졌으며, MEKPO의 열분해 최대온도는 116.8℃였다. 미분법에 의하여 얻어진 값으로부터 구한 활성화 에너지는 MEKPO와 MEKPO에 98%H₂SO₄ 1%, 3%, 5%를 첨가했을 경우에 각각 0.576㎉/㏖, 0.355㎉/㏖, 0.284㎉/㏖ 및 0.258㎉/㏖을 구하였다.

Keywords

References

  1. Thermal Decomposition Characteristics of Organic Peroxides, Occupational Safety & Health Research Institute(2001)
  2. T. C. Ho and Y S. Duh, 'Case Studies of Incidents in Runaway Reactions and Emergency Relief', Process Safety Progress, Vol. 17, No. 4, pp259-262 (1998) https://doi.org/10.1002/prs.680170406
  3. X. Li, H. Koseki, Y Iwata, J. W. Choi, and Y S. Mok, 'Risk Evaluation of Methyl Ethyl Ketone peroxide and Mixtures with Sulfuric Acid', J. DE Phys. IV France, 12, Pr7, pp393-402(2002) https://doi.org/10.1051/jp4:20020308
  4. N. Ujikawa, M. Takamura, and T. Kojima, 'Evaluation of Curing Agent Using DSC', Proceedings of the International Composite EXPO(1998)
  5. H. L. Friedman, J. Polym. Sci., Part C. 6, 183 (1963)
  6. T. Ozawa, Bull, Chem. Soc. Japan, 38, 1881(1965) https://doi.org/10.1246/bcsj.38.1881
  7. A. W. Coats., J. P. Redfern, Nature, 68, 201(1964)
  8. J. H. Flynn and L. A. Wall, Polym. Let., 4, 323(1966) https://doi.org/10.1002/pol.1966.110040504
  9. 박형주, 김기환, 김 홍, 'TGA와 가속열화를 이용한 전선피복용 PVC의 열적 열화평가', 한국소방학회지, Vol. 18, No. 3, pp45-50(2004)