Pattern of partial discharge for stator windings fault of high voltage motor

고압전동기 고정자권선 결함 부분방전패턴

  • Published : 2004.03.01

Abstract

During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[kV] and 6.67[kV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box. Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

정상적인 기계의 동작동안, 부분방전측정이 고전압전동기 고정자권선을 모의하여 터빈제너레이터 분석기(TGA)를 이용하여 실행하였다. 모의한 고정자권선에 인가된 전압은 4.47[kV]와 6.67[kV]을 인가하였다. 모의 고정자권선을 갖는 전동기들은 단자함에 80[pF]용량성 커풀러를 설치하였다. 인가전압 위상각을 고려한 부분방전패턴의 경우 2차원, 3차원적으로 보여주었다. TGA는 정규화된 펄스수(NGN)DHK 부분방전펄스크기(Qm)으로서 두개의 정량화된량을 나타내었다. 결론적으로, 우리는 모의한 고정자권선에 대한 내부방전과 표면방전의 차이를 TGA을 이용하여 식별할 수 있었다. 고정자권선의 결함에 대한 특징을 추출하기 위한 기법으로서 이산웨이블렛 변환기법 및 주파수분석법을 이용하여 결함신호에 대한 특징을 추출할 수 있었다.

Keywords