Air-Water Two-phase Flow Patterns and Pressure Distributions in a Screw-type Centrifugal Pump

  • Kim, You-Taek (Dept. of Marine System Engineering, Korea Maritime University)
  • 발행 : 2004.11.01

초록

It was reported recently that the pump head degradation near the best efficiency point from single-phase flow to the break-down due to air entrainment became less in a screw-type centrifugal pump than in a general centrifugal pump. In this paper, I carried out internal pressure measurements and visualizations, and investigated the various physical phenomena occurring inside a screw-type centrifugal pump operated in air-water two-phase flow. The results could give some characteristics about the degradation of pump performance on air-water two-phase flow.

키워드

참고문헌

  1. Tanaka. K., and Matsumoto, Y., 1988, 'Exper iment al Study of Radial Thrust on Screw Centrifugal Impeller,' Annual Report of Engineering Research Institute, Faculty of Engineering. The University of Tokyo. pp.185-192
  2. Kim, Y.T., Tanaka, K., and Matsumoto. Y., 1999. 'Tip Clearance and Bubble Size of a Screw-type Centrifugal Pump Operating in Two-phase Flow.' Proceedings of the 3rd ASME/JSME Joint Fluids Engineering Conference. FEDSM99- 7207