An Optimal Cooling Method for Long HTS Power Transmission Cable

고온초전도 케이블 냉각길이 장척화를 위한 최적 냉각방안

  • Published : 2004.09.01

Abstract

An optimal cooling method for a long HTS power transmission cable was scrutinized by using theoretical models. Cooling length of HTS cable is determined by pressure range and temperature range of LN2 in the HTS cable. Results showed limitation from temperature range is stricter than that from pressure range. The well-known one-side cooling was modified to two-side cooling. It was shown that cooling length can be nearly doubled by adopting two-side cooling of the same capacity.

Keywords

References

  1. S. Fuchino. M. Furuse and N. Higuchi. 'Longitudinal temperature distribution insuperconducting power cables with counter-flow cooling'. IEEE Transactions on Applied Superconductivity. Vol.12. No.1. pp1339-1342. 2002
  2. C. H. Lee. C. D. Kim. K. S. Kim. D. H. Kim and I. S. Kim. 'Performance of heat transfer and pressure drop in superconducting cable former'. Cryogenics. Vol.43. pp.583-588, 2003
  3. S. Fuchino. N. Tamada. I. Ishii and N. Higuchi. 'Hydraulic characteristics in superconducting power transmission cables', Physica C. Vol.354. pp.125-128. 2001
  4. S. Akita. K. Ishihara, J. Ogata and M. Nemoto. 'Development of external cooling cryoresistive cable system (Part3)'. Komae Research Laboratory Rep. No.T86081. 1987
  5. T. Masuda et al.. 'Study of a 66kV 3-core high-Tc superconducting cable (2)'. Proc. 11th Annual Conf. Power & Energy Soc. lEE Jpn .. pp.592-593. 2000