Shear induced damage of red blood cells monitored by the decrease of their deformability

  • Lee, Sung Sik (School of Chemical Engineering, Seoul National University) ;
  • Ahn, Kyung Hyun (School of Chemical Engineering, Seoul National University) ;
  • Lee, Seung Jong (School of Chemical Engineering, Seoul National University) ;
  • Sun, Kyung (Department of Thoracic and Cardiovascular Surgery, Korea University) ;
  • Goedhart, Petrus T. (Department of Clinical Physiology, Academy Medical Center) ;
  • Hardeman, Max. R. (Department of Clinical Physiology, Academy Medical Center)
  • Published : 2004.09.01

Abstract

Shear-induced damage of Red Blood Cell (RBC) is an imminent problem to be solved for the practical application of artificial organs in extra corporeal circulation, as it often happens and affects physiological homeostasis of a patient. To design and operate artificial organs in a safe mode, many investigations have been set up to correlate shear and shear-induced cell damage. Most studies were focused on hemolysis i.e. the extreme case, however, it is important as well to obtain a clear understanding of pre-hemolytic mechanical damage. In this study, the change in deformability of RBC was measured by ektacytometry to investigate the damage of RBC caused by shear. To a small magnitude of pre-shear, there is little difference, but to a large magnitude of pre-shear, cell damage occurs and the effect of shear becomes significant depending on both the magnitude and imposed time of shearing. The threshold stress for cell damage was found to be approximately 30 Pa, which is much less than the threshold of mechanical hemolysis but is large enough to occur in vitro as in the extra corporeal circulation during open-heart surgery or artificial heart. In conclusion, it was found and suggested that the decrease of deformability can be used as an early indication of cell damage, in contrast to measuring plasma hemoglobin. As cell damage always occurs during flow in artificial organs, the results as well as the approach adopted here will be helpful in the design and operation of artificial organs.

Keywords

References

  1. Brody, J. R, Y. Han, R.H. Austin and M. Bitensky, 1995, Deformation and flow of red blood cells in a synthetic lattice:evidence for an active cytoskeleton, Biophys. J. 68, 2224-2232 https://doi.org/10.1016/S0006-3495(95)80443-1
  2. Bronkhorst, P. J. H., G. J. Streekstra, J. N. Grimbergen, J. J Sixma and G. J. Brakenhoff, 1995, A new method to study shape recovery of red blood cells using multiple optical trapping, Biophys. J. 69, 1666-1673 https://doi.org/10.1016/S0006-3495(95)80084-6
  3. Discher, D. E., N. Mohandas and E. A. Evans, 1994, Molecular maps of red cell deformation: hidden elasticity and in situ connectivity, Science, 266, 1032-1035 https://doi.org/10.1126/science.7973655
  4. Fisher, T. M., R. B. Wenby and H. J. Meiselman, 1992, Pulse shape analysis of RBC micropore flow via new software for the cell transit analyser (CTA), Biorheolgy 29, 185-201
  5. Fuller, G. G. and L. G. Leal, 1980, Flow birefringence of dilute polymer solutions in two-dimensional flows Rheologica Acta: 19, 580-600
  6. Hardeman, M. R., P. Goedhart and D. Breederveld, 1987, Laser diffraction ellipsometry of erythrocytes under controlled shear stress using a rotational viscosimeter, Climica Chimica Acta 165, 227-234 https://doi.org/10.1016/0009-8981(87)90166-5
  7. Hardeman, M. R. and C. Ince, 1994, Clinical potential of in vitro measured red cell deformability, a myth? Clin. Hemorheol., 14, 619-630
  8. Hardeman, H. R., J. G. G. Dobbe and C. Ince, 2001, The laserassisted optical rotational cell analyzer (LORCA) as red blood cell aggregometer, Clin. HemorheoI Microcirc. 25, 1-11
  9. Hirayama, T, H. Herlitz, 0. Johnson and D. Roberts, 1986, Deformability and electrolyte changes of erythrocytes in Connection with open heart surgery, Scand. J. Thorac. Cardiovasc. Surg. 20, 253-259 https://doi.org/10.3109/14017438609105934
  10. Huruta, R. R., M. L. Barjas-Castro, S. T. 0. Saat, F. F.Costa, A. Fontes, L. C. Barbosa and C. L. Cesar, 1998, Mechanical Properties of stored red blood cells using optical tweezers, Blood 92, 2975-2977
  11. Kameneva, M.V., A. Undar, J. F. Antaki, M. J. Watach, J. H. Calhoon and H. S. Borovetz, 1999, Decrease in red blood cell deformability caused by hypothermia hemodilution and mechanical stress: factors related to cardiopulmonary bypass, ASAIO J. 45, 307-310 https://doi.org/10.1097/00002480-199907000-00010
  12. Kaneta, T., J. Makihara and T. Imasaka, 2001, An Optical Channel; A technique for the evaluation of biological cell elasticity, Anal. Chem. 73, 5791- 5795 https://doi.org/10.1021/ac010441g
  13. Kikichi, Y, K. Sato and Y. Mizuguchi, 1994, Modified cell flow microchannels in a single-crystal silicon substrate and flow behavior of blood cells, Microvascular Research 47, 126-139 https://doi.org/10.1006/mvre.1994.1008
  14. Lenormand, G. M., S. Henon, A. Richert, J. Simeon and F. Gallet, 2001, Measuerment of the area expansion shear moduli of the human red blood cell membrane skeleton, Biophys. J. 81, 43-56 https://doi.org/10.1016/S0006-3495(01)75678-0
  15. Mizuno, T., T. Tomonori, T. Yoshiyuki, T. Eisuke, N. Tomohiro, 0. Hiroyako, 0. Mitsuo, S. Koichi, S. Kyoko, T. Yoshiaki and T. Hisateru, 2002, Ultrastructural alterations in red blood cell membranes exposed to shear stress', ASAIO J. 48, 668-670 https://doi.org/10.1097/00002480-200211000-00017
  16. Mohandas, N., M.R. Clark, M. S. Jacobs and S. B. Shohet, 1980, Analysis of factors regulating erthorocyte deformability, J. Clin. Invest. 66, 563-573 https://doi.org/10.1172/JCI109888
  17. Mokken, F. C., M. Kedaria, C. P. Henny, M. R. Hardeman and A. A. Gelb, 1992, The clinical importance of erythrocyte deformability, a hemorheological parameter, Ann Hematol. 64, 113-122 https://doi.org/10.1007/BF01697397
  18. Needham, D. and R. S. Nunn, 1990, Elastic deformation and faiIure of lipid bilayer membranes containing cholesterol, Biophys. J. 58, 997-1009 https://doi.org/10.1016/S0006-3495(90)82444-9
  19. Sallam, A.M. and N.H.C. Hwang, 1984, Human red blood cell hemolysis in a turbulent shear flow: contribution of Reynolds shear stresses, Biorheology 21, 783-797 https://doi.org/10.3233/BIR-1984-21605
  20. Sharp, M. K. and S. F. Mohammand, 1998, Scaling of hemolysis in needles and catheters, Ann biomedical engineering 26, 788-797 https://doi.org/10.1114/1.65
  21. Sutton, N., C. Tracey and D. Johnson, R. S. Greeenaway, and M. W. Rampling, 1997, A novel instrument for studying the flow behavior of erythrocytes through microchannels simulating human blood capillaries, Microvascular Research 53, 272-281 https://doi.org/10.1006/mvre.1997.2014